Resolved Issues in ExtremeXOS 22.7.1-Patch1-3

The following issues were resolved in ExtremeXOS 22.7.1-Patch1-3. ExtremeXOS 22.7.1-Patch1-3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, and ExtremeXOS 22.7. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 22.7.1-Patch1-3

CR Number Description
General
xos0075483 The process cfgmgr ends unexpectedly when executing another save command after a failing first save command.
xos0075544 Policy process ends unexpectedly at random time, when client in the network tries to access captive portal page.
xos0075723 After re-authenticating the Dot1x client, FDB is learned on the wrong VLAN at random times.
xos0075752 The CPU utilization of process hal increases significantly after MAC authentication with NSID attribute.
xos0075939 After multiple failovers, MLAG filter is not updated in hardware resulting in traffic issues.
xos0076036 When periodic ELRP is configured on dynamic VLANs, ELRP disabled port is not re-enabled.
xos0076081 Backup root needs to be triggered for root expiry.
xos0074872 When limit learning is configured on one VLAN, FDB entries on another VLAN are flushed from hardware.
xos0075683 VC label TTL has not been set correctly in VPLS.
xos0076060 GPTP enabled state eventually goes to disabled state and "resource temporarily unavailable" error message appears in EMS log.
xos0074601 Ping is not working on MLAG port of a mixed stack of Summit X460-G2 and ExtremeSwitching X620 series switches if Summit X460-G2 is the master.
SummitStack
xos0075993 If an ARP entry changes MAC address or port number during stack failover, bcmASYNC process can end unexpectedly after failover if the same ARP changes again.
xos0068006 After rebooting the stack/slot, additional link flaps occur on 10G SFP+ passive copper and 40G QSFP+ passive cable.
Extended Edge Switching
xos0075872 Traffic loss occurs for more than 20 seconds when controlling bridge is rebooted or when you disable/enable ISC cascade port.
xos0075874 STP convergence time increases after ISC and cascade port come up or after controlling bridge (CB) reboots causing ping traffic loss.