Resolved Issues in ExtremeXOS 22.7.1-Patch1-8

The following issues were resolved in ExtremeXOS 22.7.1-Patch1-8. ExtremeXOS 22.7.1-Patch1-8 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, and ExtremeXOS 22.7. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 22.7.1-Patch1-8

CR Number Description
General
xos0074712 Process MRP ends unexpectedly with signal 6 while processing MSRP stream details.
xos0075946 On ExtremeSwitching X440G2-24x switches, Source Photonics 100FX optics link up as 1G, instead of 100 Mbps.
xos0076122 VRRP dual master seen after reboot for around 10~15 mins when MLAG reload-delay enabled.
xos0075492 ExtremeSwitching X440-G2 series switches PoE virtual temperature sensor model algorithm needs correction.
xos0075717 In VXLAN configuration, mismatch between software and hardware FDB occurs after underlay network flaps.
xos0075849 The command show ssl is not returning the output in a string when called by exes.api.exec_cli(); instead, the output is sent to the terminal.
xos0076037 MRP process ends unexpectly with signal 11 when MLAG port is down and receives MRP checkpoint from peer MLAG.
xos0076042 The command show iproute origin static shows only eight entries after reboot.
xos0076049 For QSFP+/QSFP28 optics, Rx/Tx power values do not appear correctly when fetched using SNMP.
xos0076150 Memory depletion occurs in process aaa when executing Soap/XML commands.
xos0076151 ExtremeRtStats OID is not working as expected.
xos0076184 The command show port X transceiver information detail does not show ddmi parameters for AFBR-57E6APZ-EX1 and the "-EN1" (Extreme Branded) SFPs. The command debug hal show optic ee port X does not show the ddmi page of the eeprom.
xos0076285 In ExtremeXOS 22.5+ versions, ExtremeXOS switches are not accessible through the URI/xmlService.
xos0061497 With L3VPN Dual homing, traffic is slow-path forwarded when the L3VPN peer is changed.
xos0076030 EDP does not work on a port when the port is an untagged member of a non-Default VLAN with tag 1.
xos0076134 MLAG ports do not come up after reboot when reload delay is configured.
xos0076219 In Chalet, inventory details do not appear for ONIE switches.
xos0076359 With MPLS next-hop enabled, BGP control packets do not set Dot1p values. When MPLS exp examination/replacement is enabled, the packets do not have the proper exp bits set.
xos0076480 The transmission interval of BFD control packets is changed when the BFD session is not up.
xos0076488 When MLAG convergence control is set to fast, packet drops occur on slowpath during failover.
xos0076280 PVLAN+MLAG: Isolated VLAN traffic receiving on ISC port is forwarded to local MLAG port.
xos0076478 Some MLAG ports with reload delay configured come up only after 10 seconds after reload delay.
SummitStack
xos0076215 After multiple failovers, the Multiport FDB feature does not work as expected.
xos0076152 Traffic received on ISC are not blocked and sent by the MLAG port that belongs to the same MLAG ID.
xos0076203 PVLAN feature does not work properly after a failover.