The following are new open issues for supported features found in ExtremeXOS 30.2.
Open Issues, Platform-Specific, and Feature Change Requests (CRs)
| CR Number | Description | 
|---|---|
| General | |
| xos0073899 | LACP sharing enabled port are added to link aggregator even though port speeds are different. | 
| xos0074117 | When a network is unreachable, ICMPv6 destination unreachable packets are not returned and IPv6 "InNoRoutes", ICMPv6 “DestUnreachs” Out counters are not incremented as shown in the show ipstats ipv6 vlan commmand. | 
| xos0075000 | 
                 In an unconfigured stack, if port partitioning commands are present in the
                    default.xsf file, port links may not come when the
                  unconfigured stack boots up.  
              Workaround: Save and
                    reboot of the configuration will bring up the links on the ports.  
 | 
            
| ExtremeSwitching X465 Series Switches | |
| xos0073943 | On ExtremeSwitching X465 series switches, EEE feature is not working on multi-rate ports. | 
| xos0074386 | With VIM5-4XE and VIM5-4YE modules, after rebooting the peer switch, false linkup for 10G links occur. | 
| xos0074362 | Disabling, and then enabling, the optics on
                                                  VIM5-4X/E modules does not bring up the link on
                                                  one end. The issue occurs intermittently.  Workaround: Disable, and
                                                  then enable, the ports on the peer
                                                  switch. 
 | 
                                                
| xos0074868 | For ExtremeSwitching X465 with VIM5-4YE-1 modules, high convergence times occur for EAPS, ERPS, and BFD features. | 
| xos0074580 | Total bootup time for ExtremeSwitching X465 multi-rate models is greater than 50 seconds. | 
| xos0075001 | When a slot on a X465 stack with 25G VIM is unconfigured, the ports come up in 40G mode and error are logged. | 
| ExtremeSwitching X870 Series Switches | |
| xos0074647 | On ExtremeSwitching X870 series switches, there is false linkup when reinserting Qx2Q cables. | 
| Summit X670-G2 Series Switches | |
| xos0074728 | For Summit X670-G2 stacks, if any of the 40G ports on back-up or standby nodes are configured for 4x10G port partition, upgrading to ExtremeXOS 30.2 is not recommended. | 
| Extended Edge Switching | |
| xos0074639 | With multiple bridge port extenders (BPEs)
                                                  attached to a partitioned port, starting Extended Edge
					Switching full automation by running either
                                                  the unconfigure switch or
                                                  unconfigure switch all
                                                  command removes the partitioned port
                                                  configuration, and thus full automation is not
                                                  triggered, and the Extended Edge
					Switching topology is
                                                  not created. Workaround: Do not attach BPEs to
                                                  partitioned ports, or use partial automation or
                                                  manual configuration to create the Extended Edge
					Switching topology. 
 | 
                                                
| xos0073946 | On Extended Edge Switching controlling bridge (CB) switches, the show inline-power stats command takes longer than usual to display the output, and sometimes it returns "Timeout occurred while retrieving information from hardware." messages. |