Open Issues

The following are new open issues for supported features found in ExtremeXOS 30.2.

Click to expand in new window

Open Issues, Platform-Specific, and Feature Change Requests (CRs)

CR Number Description
General
xos0073899 LACP sharing enabled port are added to link aggregator even though port speeds are different.
xos0074117 When a network is unreachable, ICMPv6 destination unreachable packets are not returned and IPv6 "InNoRoutes", ICMPv6 “DestUnreachs” Out counters are not incremented as shown in the show ipstats ipv6 vlan commmand.
xos0075000
In an unconfigured stack, if port partitioning commands are present in the default.xsf file, port links may not come when the unconfigured stack boots up.
Workaround: Save and reboot of the configuration will bring up the links on the ports.
ExtremeSwitching X465 Series Switches
xos0073943 On ExtremeSwitching X465 series switches, EEE feature is not working on multi-rate ports.
xos0074386 With VIM5-4XE and VIM5-4YE modules, after rebooting the peer switch, false linkup for 10G links occur.
xos0074362 Disabling, and then enabling, the optics on VIM5-4X/E modules does not bring up the link on one end. The issue occurs intermittently.
Workaround: Disable, and then enable, the ports on the peer switch.
xos0074868 For ExtremeSwitching X465 with VIM5-4YE-1 modules, high convergence times occur for EAPS, ERPS, and BFD features.
xos0074580 Total bootup time for ExtremeSwitching X465 multi-rate models is greater than 50 seconds.
xos0075001 When a slot on a X465 stack with 25G VIM is unconfigured, the ports come up in 40G mode and error are logged.
ExtremeSwitching X870 Series Switches
xos0074647 On ExtremeSwitching X870 series switches, there is false linkup when reinserting Qx2Q cables.
Summit X670-G2 Series Switches
xos0074728 For Summit X670-G2 stacks, if any of the 40G ports on back-up or standby nodes are configured for 4x10G port partition, upgrading to ExtremeXOS 30.2 is not recommended.
Extended Edge Switching
xos0074639 With multiple bridge port extenders (BPEs) attached to a partitioned port, starting Extended Edge Switching full automation by running either the unconfigure switch or unconfigure switch all command removes the partitioned port configuration, and thus full automation is not triggered, and the Extended Edge Switching topology is not created.
Workaround: Do not attach BPEs to partitioned ports, or use partial automation or manual configuration to create the Extended Edge Switching topology.
xos0073946 On Extended Edge Switching controlling bridge (CB) switches, the show inline-power stats command takes longer than usual to display the output, and sometimes it returns "Timeout occurred while retrieving information from hardware." messages.