Resolved Issues in ExtremeXOS 30.5

The following issues were resolved in ExtremeXOS 30.5. ExtremeXOS 30.5 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, and ExtremeXOS 30.4. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.5
CR Number Description
General
xos0061497 With L3VPN Dual homing, traffic is slow-path forwarded when the L3VPN peer is changed.
xos0075656 On SummitStacks, running the commands disable/enable netlogin dot1x globally takes a very long time to execute.
xos0076412 The command show port port_list output is aborted with an error when an optics is removed from an active port.
xos0076562 Router advertisements are processed on L2 VLANs resulting in routes being installed (if prefix is present) causing connectivity issues to those prefixes.
xos0076581 The command show vlan tag does not display VLAN information.
xos0076885 HTTPS sessions persist in "CLOSE_WAIT" state resulting in web access issues.
xos0077169 In MLAG topologies, FDB is removed randomly in an the MLAG peer, which causes connectivity issues.
xos0077318 ExtremeXOS fails to send XML notification to the XML server.
xos0077389 EDP process ends unexpectedly if the name of a VLAN configured with the command "CDP management-address vlan" is changed.
ExtremeSwitching X870 Series Switches
xos0077094 Switch incorrectly defers sending tech-support data at the configured interval in some scenarios.
xos0077100 Switch fails to send tech-support data to collector after reboot.
ExtremeSwitching X620 Series Switches
xos0076939 The command "show tech all logto file" returns a corrupted gzip file.
ExtremeSwitching X435 Series Switches
xos0076409 On the ExtremeSwitching X435 series switches, copying an image to the inactive partition from the active partition is not supported.
xos0076719 For ExtremeSwitching X435-8P-2T-W switches for PoE uplink port combination either 0W + 30W or 30W + 0W, budgeted power is the guard band value (20W) instead of 0W.
ExtremeSwitching X690 Series Switches
xos0076930 On ExtremeSwitching X690 series switches, even though "Auto-negotiation OFF" is configured on a port, the port defaults to "Auto-negotiation ON" at the hardware level after a reboot.
ExtremeSwitching X460-G2 Series Switches
xos0076705 Cable diagnostics are not working on Summit X460G2-16mp switches.
ExtremeSwitching X440-G2 Series Switches
xos0076423 DDMI information not appearing in relevant show commands.
BGP Auto-peering
xos0076643 In multi-homed ECMP scenarios, missing routes occur for some of those ECMP destinations after rebooting switches. A multi-homed ECMP is when two switches have more than one link adjacency to one another. An ECMP destination is the adjacent switch‘s router ID. In this case, some links are not used.
xos0075897 With MLAG + BGP Auto-peering, incomplete ARP entry for host mobility routes occurs after disabling, and then enabling, an MLAG port.
ELRP
xos0076321 ELRP takes 3-15 seconds to disable a loop detected on a port on a standby node.
xos0076376 ELRP packets are transmitted with checksum errors.
Extended Edge Switching
xos0075419 On Extended Edge Switching, mirroring using policy/ACLs with a mirror destination on extended ports is not working.
xos0075180 On an Extended Edge Switching ring setup with MLAG, with scaled VRRP and PIM configuration and slow path traffic, such as ARP and IGMP joins, PIM process ends unexpectedly with signal 6.
xos0075756 With ExtremeSwitching X590 as the CB in a ring topology, running the unconfigure switch command with the default.xsf file present causes the ring to remain in a severed state.
xos0075869 After running reboot all from MLAG master, ring stays as linear cascade in MLAG master, and ring stays in severed state in MLAG peer with ring not established.
xos0076237 In a ring topology, adding a new slot between two slots, and then rebooting the adjacent slot, and then the new slot produces the error: configVlanRemovePort:3110: KERNEL_EXVLAN_ERROR.
OSPF
xos0076593 OSPF AS external routes are removed when one of the two paths go down out of which one is inter-area path and another is intra-area path.
ONEPolicy
xos0076317 Policy with match condition as "route-origin rip" and action to modify cost is not functioning in RIP.
Security
xos0068278 IP security snooping is not working for clients in sub-VLAN. Violation is detected correctly, but the corresponding action is not triggered.
xos0068638 If NetLogin authentication mode option is selected, the web authentication commands should fail and show the error message "ERROR: web-based and "authentication optional" cannot be enabled simultaneously on a port".
xos0076337 Netlogin and Policy: LLDP packets are not sent or received, even after successful authentication, if the port is not part of any base/destination VLAN.
xos0076447 TLS transactions sometime encounter issues when clients send packets after a delay.
xos0076816 The NTP association takes a while to be updated when the interface goes down or comes back up.
xos0077069 With ONEPolicy enabled and admin profile configured on the port, ICMP reply is lost momentarily if ICMP and LLDP packets reach the switch at the same time.
xos0074696 Using Extreme Management Center to configure NetLogin does not work reliably.
STP
xos0077005 In an STP with MLAG configuration, ISC port cost should appear as "0" under the command show stp domain_nameports output.
SummitStack
xos0076764 After failover, OSPFv3 routes are not removed from new master node.
xos0076956 IPFIX does not work on a stack when a master node does not support IPFIX.