The following issues were resolved in ExtremeXOS 30.5. ExtremeXOS 30.5 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, and ExtremeXOS 30.4. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0061497 | With L3VPN Dual homing, traffic is slow-path forwarded when the L3VPN peer is changed. |
xos0075656 | On SummitStacks, running the commands disable/enable netlogin dot1x globally takes a very long time to execute. |
xos0076412 | The command show port port_list output is aborted with an error when an optics is removed from an active port. |
xos0076562 | Router advertisements are processed on L2 VLANs resulting in routes being installed (if prefix is present) causing connectivity issues to those prefixes. |
xos0076581 | The command show vlan tag does not display VLAN information. |
xos0076885 | HTTPS sessions persist in "CLOSE_WAIT" state resulting in web access issues. |
xos0077169 | In MLAG topologies, FDB is removed randomly in an the MLAG peer, which causes connectivity issues. |
xos0077318 | ExtremeXOS fails to send XML notification to the XML server. |
xos0077389 | EDP process ends unexpectedly if the name of a VLAN configured with the command "CDP management-address vlan" is changed. |
ExtremeSwitching X870 Series Switches | |
xos0077094 | Switch incorrectly defers sending tech-support data at the configured interval in some scenarios. |
xos0077100 | Switch fails to send tech-support data to collector after reboot. |
ExtremeSwitching X620 Series Switches | |
xos0076939 | The command "show tech all logto file" returns a corrupted gzip file. |
ExtremeSwitching X435 Series Switches | |
xos0076409 | On the ExtremeSwitching X435 series switches, copying an image to the inactive partition from the active partition is not supported. |
xos0076719 | For ExtremeSwitching X435-8P-2T-W switches for PoE uplink port combination either 0W + 30W or 30W + 0W, budgeted power is the guard band value (20W) instead of 0W. |
ExtremeSwitching X690 Series Switches | |
xos0076930 | On ExtremeSwitching X690 series switches, even though "Auto-negotiation OFF" is configured on a port, the port defaults to "Auto-negotiation ON" at the hardware level after a reboot. |
ExtremeSwitching X460-G2 Series Switches | |
xos0076705 | Cable diagnostics are not working on Summit X460G2-16mp switches. |
ExtremeSwitching X440-G2 Series Switches | |
xos0076423 | DDMI information not appearing in relevant show commands. |
BGP Auto-peering | |
xos0076643 | In multi-homed ECMP scenarios, missing routes occur for some of those ECMP destinations after rebooting switches. A multi-homed ECMP is when two switches have more than one link adjacency to one another. An ECMP destination is the adjacent switch‘s router ID. In this case, some links are not used. |
xos0075897 | With MLAG + BGP Auto-peering, incomplete ARP entry for host mobility routes occurs after disabling, and then enabling, an MLAG port. |
ELRP | |
xos0076321 | ELRP takes 3-15 seconds to disable a loop detected on a port on a standby node. |
xos0076376 | ELRP packets are transmitted with checksum errors. |
Extended Edge Switching | |
xos0075419 | On Extended Edge Switching, mirroring using policy/ACLs with a mirror destination on extended ports is not working. |
xos0075180 | On an Extended Edge Switching ring setup with MLAG, with scaled VRRP and PIM configuration and slow path traffic, such as ARP and IGMP joins, PIM process ends unexpectedly with signal 6. |
xos0075756 | With ExtremeSwitching X590 as the CB in a ring topology, running the unconfigure switch command with the default.xsf file present causes the ring to remain in a severed state. |
xos0075869 | After running reboot all from MLAG master, ring stays as linear cascade in MLAG master, and ring stays in severed state in MLAG peer with ring not established. |
xos0076237 | In a ring topology, adding a new slot between two slots, and then rebooting the adjacent slot, and then the new slot produces the error: configVlanRemovePort:3110: KERNEL_EXVLAN_ERROR. |
OSPF | |
xos0076593 | OSPF AS external routes are removed when one of the two paths go down out of which one is inter-area path and another is intra-area path. |
ONEPolicy | |
xos0076317 | Policy with match condition as "route-origin rip" and action to modify cost is not functioning in RIP. |
Security | |
xos0068278 | IP security snooping is not working for clients in sub-VLAN. Violation is detected correctly, but the corresponding action is not triggered. |
xos0068638 | If NetLogin authentication mode option is selected, the web authentication commands should fail and show the error message "ERROR: web-based and "authentication optional" cannot be enabled simultaneously on a port". |
xos0076337 | Netlogin and Policy: LLDP packets are not sent or received, even after successful authentication, if the port is not part of any base/destination VLAN. |
xos0076447 | TLS transactions sometime encounter issues when clients send packets after a delay. |
xos0076816 | The NTP association takes a while to be updated when the interface goes down or comes back up. |
xos0077069 | With ONEPolicy enabled and admin profile configured on the port, ICMP reply is lost momentarily if ICMP and LLDP packets reach the switch at the same time. |
xos0074696 | Using Extreme Management Center to configure NetLogin does not work reliably. |
STP | |
xos0077005 | In an STP with MLAG configuration, ISC port cost should appear as "0" under the command show stp domain_nameports output. |
SummitStack | |
xos0076764 | After failover, OSPFv3 routes are not removed from new master node. |
xos0076956 | IPFIX does not work on a stack when a master node does not support IPFIX. |