The following are new open issues for supported features found in ExtremeXOS 30.5.
CR Number | Description |
---|---|
General | |
xos0077732 | After a reboot simultaneous running of the show system command on 8 Telnet/SSH sessions results in cli master crash. |
ExtremeSwitching X435 Series Switches | |
xos0076797 | On ExtremeSwitching X435 series switches, changing autonegotation from "on" to "off" with 10MB speed selected, the configuration change is not reflected on the peer switch. |
xos0076886 | On ExtremeSwitching X435 series switches, egress ACLs are not supported. |
xos0077747 | On ExtremeSwitching X435 series switches, HCLAG is not supported. |
xos0077251 | On ExtremeSwitching X435 series switches, core dump information is not preserved (as shown in show debug system-dump) after rebooting. |
xos0077507 |
WDRR scheduling is not currently supported on ExtremeSwitching X435 series switches. Workaround: Use WRR for alternative scheduling. |
xos0077774 | On ExtremeSwitching X435 series switches, AVB on copper optics and 100M fiber optics using SFP ports is not supported. |
ExtremeSwitching X460-G2 Series Switches | |
xos0076994 | In the presence of continuous L2 traffic, after a port comes up after a reboot, the "Flood Rate Exceeded" counter shown in the command show port 21 rate-limit flood no-refresh output does not update immediately. |
ExtremeSwitching X440-G2 Series Switches | |
xos0077772 | On ExtremeSwitching X440-G2 series switches using 1G optics on 10G ports, ports do not come up after rebooting. |
xos0077718 | On ExtremeSwitching X440-G2 series switches with auto-discovery enabled, 10G ports 25/26 go down after reboot if ports 27/28 have optics attached or if stacking support is enabled. |
Security | |
xos0077164 | Authenticated NetLogin user's entries are flushed when new member port is added into a LAG group. |