The following issues were resolved in ExtremeXOS 30.7.1-Patch1-86. ExtremeXOS 30.7.1-Patch1-86 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.
Defect | Description |
---|---|
General | |
EXOS-27856 | Adds support for disable/enable iqagent. |
EXOS-27857 | disable iqagent configuration is not reflected in show configuration output. |
EXOS-27564 | When configuring LAG on extended ports, short loop is detected in switch. |
EXOS-27919 | In VPEX one armed MLAG ring topology, multicast traffic drop observed after link flap of native cascade port in controlling bridge. |
EXOS-27855 | Irrelevant log messages from VLAN module <Info:vlan.mac.gMacArrayDump> is seen after switch reboot. |
EXOS-27928 | MLAG up/down messages are not displayed by default in log. |
EXOS-27998 | Identity-management entries were not removed after running clear netlogin state port. |
EXOS-27215 | When the mgmt port is down with IQAgent, enable dhcp vlan mgmt log message prints every 2 minutes. |
EXOS-26928 | DHCP broadcast packets are flooded through the client port in non-policy netlogin mode when broadcast flooding is disabled on ports. |
EXOS-27867 | Update show fdb output to mention Age displayed as 0 for hardware aging platforms. |
EXOS-27704 | EXSH process crashed with signal 6 on issuing double TAB after alias name. |
EXOS-27603 | Non-partitioned 40G ports in backup/standby slots are showing incorrect port status after stack reboots. |
EXOS-27719 | After running port statistics-related commands, the CLI stops responding. |
EXOS-19439 | Error message "Failed to set fec config" observed during switch reboot or stack failover with 4x10G partition configuration. |
EXOS-27810 | VPEX topology shows Severed state when powering on/off all BPEs at the same time. |
EXOS-27742 | When disabling one of the ring ports and rebooting an extended slot in VPEX ring, all ports in extended slots remain in 'Ready' state. |
EXOS-27469 | In VPEX MLAG topology, the nodealias process ends unexpectedly when SNMP polling was run to fetch nodealias information from extended slots. |
EXOS-27971 | ICMP packets are not egressing after failover. |
EXOS-27883 | CLI process consumes more CPU when enable debug-mode command is executed and the session gets timed out. |
EXOS-27508 | Authentication for local user fails for SSH connection. Radius server is unreachable. |
EXOS-27373 | HAL error message seen when changing auto-polarity on a port. |
EXOS-27578 | DHCP/BOOTP relay packets forwarded to the wrong VLAN, causing connectivity issues for PXE client. |
EXOS-27477 | STP PDU not sent out immediately on Admin enable operation if edge port is configured with edge safeguard and BPDU restrict is enabled. |
EXOS-27957 | RTMGR process crashed with signal 6 due to stale BGP entries. |
EXOS-27716 | ELRP process ends unexpectedly after receiving an invalid packet with ELRP destination MAC address. |
EXOS-27557 | show fabric attach elements output does not display all attached elements if the number of elements is greater than 25. |
ExtremeSwitching X460-G2 Series Switches | |
EXOS-27661 | Two-Way Active Measurement Protocol (TWAMP) feature is not working as expected. |
EXOS-27745 | PTPv2 mean path delay metric is not displayed correctly. |
EXOS-27668 | High HAL utilization observed with Network Timing license. |
ExtremeSwitching X770 Series Switches | |
EXOS-27828 | On upgrade to 22.7 and later releases, thttpd and related processes are stuck in the load configuration state if there is an excess amount of VLAN configuration. |
SummitStack | |
EXOS-27999 | ZTPstack cannot successfully configure a new switch to join the stack if the currently active Stack MAC address is based on the node that is not currently present in stack. |