Resolved Issues in ExtremeXOS 30.7.1-Patch1-23

The following issues were resolved in ExtremeXOS 30.7.1-Patch1-23. ExtremeXOS 30.7.1-Patch1-23 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.7.1-Patch1-23
Defect Number Description
General
EXOS-26944 IQ Agent ends unexpectedly when SNMP is blocked.
EXOS-26445 Need support for image integrity check in ExtremeXOS.
EXOS-27029 IQ Agent version 0.3.11 is not providing the patch information in the "osVersion" object in the association request to ExtremeCloud IQ.
EXOS-26908 DNS packets are not processed on the NetLogin VLAN when an IP address is re-configured, and when a NetLogin web-enabled port is not a member of the NetLogin VLAN.
EXOS-26816

AnSCP2 client session using the cipher option to transfer files from the switch to an SCP server produces the following error: Error:can't read "args(<cipher>)": no such element in array.

EXOS-26901 When you configure an explicit time using the configure time command, the switch might experience traffic loss or perform software forwarding instead of hardware forwarding.
EXOS-26953 VPEX process ends unexpectedly when processing checkpoint messages from an MLAG peer with a non-existent slot number.
EXOS-26898 SSH logon fails after repeated SSH logon/logoff attempts.
EXOS-26729

On LACP in BGP/EVPN VXLAN configurations, missing FDB MACs and ARPs occur from a remote VTEP with the following log message on the remote VTEP:

<Warn:BGP.UpdateMgr.RtNotAdvertLargeUpdtMsg> A route can not be advertised because it is too large to fit into the maximum allowed size of a BGP UPDATE message. VR = <vr number> Destination address AFI/SAFI = 4587545 Destination address prefix =<7 32 bit Hex strings forming the BGP route prefix> Destination address prefix length = 216
EXOS-26128 ExtremeXOS ignores LLDP PDUs from auth-override (AP-aware) ports.
EXOS-26795 After deleting virtual-link-local configurations, VRRP process ends unexpectedly.
EXOS-26818 Infrequently, after enabling SSH, the process exsshd ends unexpectedly due to EPM timeout.
EXOS-26603 Traffic between hosts using LAG is not hashed on the same port with XOR hash algorithm if the number of sharing ports is not power of 2.
EXOS-26697 Even after enabling a disabled port, ELRP disabled logs are not cleared.
EXOS-10852

When the wrong ARP packets are received on tenant VLANs, the following VXLAN error messages occur:

04/12/2020 18:24:54.76 <Erro:HAL.VNet.Error> Failed to Add Net Port for RTEP:1 RtepAddr:192.168.253.2 LtepAddr:192.168.253.1 portType:2 err Generic Error
04/12/2020 18:24:54.76 <Erro:HAL.VXLAN.Error> Cannot create BUM port in standard mode.
EXOS-26825 After upgrading to ExtremeXOS 30.1, Identity manager Kerberos snooping stops working.
EXOS-26814 Number of SSH key files in /usr/local/cfg and show config exsshd are not equal.
EXOS-26815 Infrequently, when enabling SSH, the process exsshd ends unexpectedly due to EPM timeout.
EXOS-26817 If a configuration file saved in an older ExtremeXOS release is used, even after generating fresh key, SSH port 22 is not open.
EXOS-26952 On Extended Edge Switching MLAG topologies, the layer 2 traffic that is hashed to the specific port of VPLAG is dropped.
SummitStack
EXOS-26824 When hosts move from a network VLAN to a subscriber VLAN, HAL process ends unexpectedly.
EXOS-20565 When nodes are automatically added or replaced on a stack, the command show inline-power slot master_slot fails.
ExtremeSwitching X440-G2 Series Switches
EXOS-24091 On a few ExtremeSwitching X440-G2 series switches, upgrading from any ExtremeXOS 22.x version to ExtremeXOS 30.3, or later, fails due to partition error.
ExtremeSwitching X460-G2 Series Switches
EXOS-10884 If a bulk number of FDB entries age out at same time, excessive MAC move notifications appear from hardware.