Resolved Issues in ExtremeXOS 30.7.3-Patch1-19

The following issues were resolved in ExtremeXOS 30.7.3-Patch1-19. ExtremeXOS 30.7.3-Patch1-19 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.7.3-Patch1-19
Defect Description
General
EXOS-30164 After “max-failed-login” + 1 failed login attempts, the first login failure is not recorded and the user gets locked out.
EXOS-30252 Enabling VRRP Fabric Routing shouldn't be allowed on a VRRP group when a group member has priority 255.
EXOS-30767 The functionality iparp add proxy stopped working after an upgrade in ExtremeXOS 30.2 and later releases.
EXOS-31275 The forwarding database (FDB) doesn't expire after moving the MAC via IPARP packet in one of the MLAG ports.
EXOS-31321 The configuration configure elrp-client disable-ports is lost after a switch reboot.
EXOS-31331 When multiple actions are configured in a UDP forwarding profile, only the first entry's forwarding actions are carried out, despite the received packet matching multiple entries.
EXOS-31335 The switch reboots due to a process “OSPF” crash.
EXOS-31440 The configure system ports notation slot:port command returns an error and the port's notation cannot be changed to slot:port.
EXOS-31449 Multicast Source Discovery Protocol (MSPD) process crashes while processing packets of higher length.
EXOS-31451 A ping fails between tenant VLANs located in PE switches after re-adding a tenant VLAN in a VXLAN configuration.
EXOS-31546 Process forwarding database (FDB) crashes when the switch receives an SNMP walk for MIB extremeFdbPermFdbTable.
EXOS-31559 Include STP-related show commands in the show tech command when STP is enabled.
EXOS-31561 Edge-Safeguard disables an MLAG port when the MLAG device reboots, with with no signs of a loop.
EXOS-31570 HAL process crashes with signal 6 after continuous port flap.
SummitStack
EXOS-31508 Backup SummitStack slots suddenly reboot after approximately 1,382 days of uptime.
ExtremeSwitching X440-G2 Series Switches
EXOS-31071 In ExtremeSwitching X440-G2 series switches, summitCardGetMaxPhyTemp error messages occur for port 52 in an idle switch.