Resolved Issues in ExtremeXOS 30.7.2-Patch1-33

The following issues were resolved in ExtremeXOS 30.7.2-Patch1-33. ExtremeXOS 30.7.2-Patch1-33 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.7.2-Patch1-33
Defect Description
General
EXOS-28961 An authentication failed log appears for the Network login 802.1x user, even when there is no EAPOL response from the client.
EXOS-29431 On upgrading from ExtremeXOS 30.2 to an ExtremeXOS 30.3 or later release, the IP security module removes configuration after violation-none.
EXOS-29486 If nodealias and netlogin are enabled on the same port, then the nodealias entry will not be created for a client unless the client sends a packet destined for the switch CPU.
EXOS-29508 L3VPN routes are not installed if VPN VRF is configured after the BGP neighbor.
EXOS-29543 Introduce a CLI to the unconfigure dhcp-binding storage filename command.
EXOS-29764 Netlogin authentication fails when VLAN is statically created but the dynamic VLAN creation request is received from a RADIUS accept packet.
EXOS-29821 RTMGR process crashed with signal 11 when an IPv6 tunnel packet is received despite the switch not having tunneling configuration.
Extended Edge Switching
EXOS-29450 The VPEX process ends unexpectedly right after the Controlling Bridge (CB) boot up if the loaded configuration is different from the saved configuration.
EXOS-29826 In a VPEX environment, the HAL process ends unexpectedly on a reboot of the Controlling Cridge (CB).
EXOS-29827 In a VPEX MLAG Multiple Ring topology, when reboot all is run from one of the CBs, rings are stuck in the "Topology: Ring (Severed) - Formation Disabled" state.
ExtremeCloud IQ
EXOS-29833 After disabling IQ Agent, the switch is continuously trying to establish a connection with ExtremeCloud IQ when it is not reachable.
VXLAN
EXOS-29531 VXLAN error messages are observed and a port is not added to hardware table.