Resolved Issues in ExtremeXOS and Switch Engine 31.7.2-Patch1-64

The following issues were resolved in ExtremeXOS 31.7.2-Patch1-64. Version 31.7.2-Patch1-64 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, 31.5, 31.6, and 31.7. For information about those fixes, see the release notes for the specific version.

Version 31.7 also includes fixes for issues found in Switch Engine 31.6. Version 31.6 was the first version of Switch Engine.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 31.7.2-Patch1-64
Defect Number Description
General
CFD-9407 Switch brings up the ports when diagnostics tests are running.
CFD-9930 ACL Signal 11 crash occurs when ACL is added from a script and the process crash causes a switch restart.
CFD-9931 In certain scenarios, ARP entry is not refreshed after a MAC move.
CFD-9984 Switch restarts because of a kernel crash.
CFD-10024 The route does not become active after executing the disable/enable bgp command.
CFD-10025 ExtremeXOS is not switching the route to L3VPN prefix when the configured static route goes down.
CFD-10026 PMBR floods multicast streams into VLANs without subscribers.
CFD-10027 Router-discovery configurations missing after disabling/enabling VRRP instance.
CFD-10028 SCP should choose vr-default as default VRs for operations, for example, download, in platforms that do not have a dedicated management port.
CFD-10177 SNMP traps were not getting generated when there is an IP Security ARP violation despite the corresponding configuration being present in the switch.
CFD-10186 VRRP hellos are dropped when they are forwarded over ISC.
CFD-10203 Kernel oops occurs when VPLS pseudo-wire goes down.
CFD-10224 FDB process crash occurs when polling fdb.ipNetToPhysicalEnt MIB.
EXOS-34819 Several Extreme Networks certified optics are marked incorrectly as unsupported and also have link-related issues.
EXOS-34924 NetTools.AllocRawSockFail error message displays when more VLANs are created/deleted dynamically over a period of time.
EXOS-35036 EXPY process crash with signal 6 occurs.
EXOS-35117 VPEX MLAG ring gets moved to severed state when excessive control packets are forwarded.
ExtremeSwitching X435 Series Switches
CFD-10029 ExtremeSwitching X435 switches send extremeOverheat traps despite device temperature being under the high temperature threshold.
ExtremeSwitching 5420 Series Switches
EXOS-34746 After a stack restart, a 25G port inserted with 10G 10301 optic transceiver goes down in Backup and Standby nodes.
ExtremeSwitching 5520 Series Switches
CFD-10031 Error message occurs when creating LAG with Primary and Backup node VIM ports.
SummitStack
CFD-9922 Image was not synced to the Standby node in the stack when copying the image by using SFTP put in the server.
CFD-10021 On a stack, the Backup and Standby slot port configuration information is not returned when ExtremePortConfigTable is polled.
CFD-10022 MLT session was not running after enable/disable jumbo-frames when ExtremeXOS stack is enabled with VPEX.
CFD-10219 HAL process crash occurs when sending multicast packets to more than 33 BPEs, and when disabling/enabling the ports in a BPE.
EXOS-34968 SNMP Mibs ifSpeed and ifHighSpeed are displayed in Gbps rather than bps for stack-ports.