The following issues were resolved in ExtremeXOS 31.7.1-Patch1-98. Release 31.7.1-Patch1-98 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, 31.5, 31.6, and 31.7. For information about those fixes, see the release notes for the specific release.
Release 31.7 also includes fixes for issues found in Switch Engine 31.6. Release 31.6 was the first version of Switch Engine.
Defect Number | Description |
---|---|
General | |
EXOS-26927 | During TFTP get operation, if the local-file name is mentioned as just `dot`, as in ".", then the permissions for home directory are changed. |
EXOS-31551 | Traffic loss after VPWS instance is removed from a port. |
EXOS-32268 | REST API query times out if there are unreadable characters in the optic-info. |
EXOS-32435 | IdMgr process crashed with signal 11 on reception of invalid UDP packet length. |
EXOS-33014 | Switch unresponsive after upgrading from 30.7.1 Patch1-103 to 31.7.1 Patch1-36 with ONEPolicy configuration. |
EXOS-33015 | Transceiver RxPower values are displayed incorrectly in switch logs. |
EXOS-33016 | PIM router stops the stream after IGMP leaves on another router despite there being an active subscriber on the port. |
EXOS-33030 | 100G to 25G Amphenol Break-out cables are displayed as unsupported. |
EXOS-33108 | If SSH2 is disabled when the SSH key is invalid, the switch hangs and cannot be recovered until a hard reboot. |
EXOS-33188 | Extended view should be used by Switch Engine once it learns more than 10K IPARP entries. |
EXOS-33208 | Valid LLDP packet gets processed as an STP packet. |
Extended Edge Switching | |
EXOS-32532 | Random BPE slots rebooting with the message "CSP SR Wait Timer expired for BPE." |
EXOS-33140 | VPEX Controlling Bridge reboots due to Memory Depletion. |
ExtremeSwitching X435 Series Switches | |
EXOS-32881 | On the ExtremeSwitching X435-8p-4s switch, downgrading ExtremeXOS from a higher version to a lower version can render the PoE permanently inoperable, resulting in an RMA being needed to recover PoE functionality. |
EXOS-33036 | PoE error messages are logged when an ExtremeSwitching X435-8p-4s switch is rebooted. |
EXOS-33198 | Adding a debug CLI command to correct bad portmap in ExtremeSwitching X435 switches for PoE issues. |
VLAN | |
EXOS-33029 | VLAN auto-move deletes VLANs on ports even if the VLAN is tagged on the port. |