Resolved Issues in ExtremeXOS and Switch Engine 31.7.1-Patch1-98

The following issues were resolved in ExtremeXOS 31.7.1-Patch1-98. Release 31.7.1-Patch1-98 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, 31.5, 31.6, and 31.7. For information about those fixes, see the release notes for the specific release.

Release 31.7 also includes fixes for issues found in Switch Engine 31.6. Release 31.6 was the first version of Switch Engine.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 31.7.1-Patch1-98
Defect Number Description
General
EXOS-26927 During TFTP get operation, if the local-file name is mentioned as just `dot`, as in ".", then the permissions for home directory are changed.
EXOS-31551 Traffic loss after VPWS instance is removed from a port.
EXOS-32268 REST API query times out if there are unreadable characters in the optic-info.
EXOS-32435 IdMgr process crashed with signal 11 on reception of invalid UDP packet length.
EXOS-33014 Switch unresponsive after upgrading from 30.7.1 Patch1-103 to 31.7.1 Patch1-36 with ONEPolicy configuration.
EXOS-33015 Transceiver RxPower values are displayed incorrectly in switch logs.
EXOS-33016 PIM router stops the stream after IGMP leaves on another router despite there being an active subscriber on the port.
EXOS-33030 100G to 25G Amphenol Break-out cables are displayed as unsupported.
EXOS-33108 If SSH2 is disabled when the SSH key is invalid, the switch hangs and cannot be recovered until a hard reboot.
EXOS-33188 Extended view should be used by Switch Engine once it learns more than 10K IPARP entries.
EXOS-33208 Valid LLDP packet gets processed as an STP packet.
Extended Edge Switching
EXOS-32532 Random BPE slots rebooting with the message "CSP SR Wait Timer expired for BPE."
EXOS-33140 VPEX Controlling Bridge reboots due to Memory Depletion.
ExtremeSwitching X435 Series Switches
EXOS-32881 On the ExtremeSwitching X435-8p-4s switch, downgrading ExtremeXOS from a higher version to a lower version can render the PoE permanently inoperable, resulting in an RMA being needed to recover PoE functionality.
EXOS-33036 PoE error messages are logged when an ExtremeSwitching X435-8p-4s switch is rebooted.
EXOS-33198 Adding a debug CLI command to correct bad portmap in ExtremeSwitching X435 switches for PoE issues.
VLAN