The following issues were resolved in ExtremeXOS 31.7.2. Release 31.7.2 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, 31.5, 31.6, and 31.7. For information about those fixes, see the release notes for the specific release.
Release 31.7 also includes fixes for issues found in Switch Engine 31.6. Release 31.6 was the first version of Switch Engine.
Defect Number | Description |
---|---|
General | |
EXOS-32692 | DHCP continuously occurs when lease-time is infinite. |
EXOS-32719 | During the execution of the show access-list counter command in a stack, a Hal process crash occurs. |
EXOS-33105 | The output of the command show port 63 transceiver is delayed by few seconds. |
EXOS-33308 | Last successful login time is not same as system time. |
EXOS-33325 | 0A HEX Value Appended to the end of extremeLastChangeConfigTime OID. |
EXOS-33439 | The operating system sends a double authentication request for the same client on an LLDP-enabled port |
EXOS-33460 | Stack not sending extremeStackMemberOverheat trap for individual members. |
EXOS-33471 | IP security crash occurs on the MLAG peer while a DHCP ACK packet with option 61 is checkpointed. |
EXOS-33478 | Local authentication failover doesn't work when using Chalet. |
EXOS-33509 | Turning autopolarity off might not take effect on a port running at 10Mbps or 100Mbps. |
EXOS-33517 | The show fdb stats command doesn't show display strings for the LAG master port. |
EXOS-33556 | The show forward-error-correction command output is slow when displaying the information for ports that are not present. |
EXOS-33564 | PoE show outputs Missing in Show Tech when the switch is loaded with a default configuration. |
EXOS-33606 | The PIM cache entry is not cleared when anycast RP is configured. |
EXOS-33679 | A multicast cache entry times out despite continuous traffic to the destination multicast IP. |
ExtremeSwitching X440-G2 Series Switches | |
EXOS-33173 | On an ExtremeSwitching 440-G2-24X/48X switch, Finisar 1000BASE-T optic does not link-up when configured for 100 Mbps with Auto-Negotiation disabled and speed set to 100 Mbps. |
ExtremeSwitching X465 Series Switches | |
EXOS-33281 | Half duplex not working with speed 100 auto off in the ExtremeSwitching X465 switch. |
ExtremeSwitching X620 Series Switches | |
EXOS-31733 | Failed to get phy temperature sensors for sloterror displays in the ExtremeSwitching X620 switch. |
ExtremeSwitching X695 Series Switches | |
EXOS-33549 | IGMP joins are forwarded with an extra tag by the ExtremeSwitching X695 switch when the port is part of both a VMAN and a VLAN. |
SummitStack | |
EXOS-33289 | Node failure occurs in an 8-node ExtremeSwitching 5420 series stack during upgrade. |
Extended Edge Switching | |
EXOS-33609 | Random BPE slots rebooting with a CSP SR Wait Timer expired for BPE message. |