Resolved Issues in ExtremeXOS and Switch Engine 31.7.2-Patch1-75

The following issues were resolved in ExtremeXOS 31.7.2-Patch1-75. Version 31.7.2-Patch1-75 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, 31.5, 31.6, and 31.7. For information about those fixes, see the release notes for the specific version.

Version 31.7 also includes fixes for issues found in Switch Engine 31.6. Version 31.6 was the first version of Switch Engine.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 31.7.2-Patch1-75
Defect Number Description
General
CFD-10136 Access-list policy rules containing TCP/UDP port range and IP address are not configured properly on the switch when enforced using ExtremeCloud IQ - Site Engine.
CFD-10461 When a new dot1x client is authenticated on a port, the accounting stop is not sent for the old dot1x client and the accounting start is not sent for the new client.
CFD-10478 rtmgr process crash occurs when enabling BFD on IPv6 prefix.
CFD-10509 mcmgr process crash occurs when fast-leave is enabled and receiving a leave message.
CFD-10510 MACsec ports were not active after switch restart.
CFD-10561 Netlogin client not learned on the port after STP convergence.
CFD-10563 A local file will be used to restore DHCP-binding information if the remote server is unreachable.
Extended Edge Switching
CFD-10382 The show tech-support command gets stuck at show vpex command with a specific configuration.
SummitStack