Resolved Issues in ExtremeXOS 31.6

The following issues were resolved in ExtremeXOS 31.6. Release 31.6 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, and 31.5. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 31.6
Defect Number Description
General
EXOS-29654 DHCP Offer and Acknowledgement packets are broadcasted on all sub-VLANs when the switch acts as a relay agent.
EXOS-30037 The show ipconfig command output breaks when CLI mode is configured as "non-persistent."
EXOS-30074 In a SummitStack with a mirror and the source port in non-master node, a loop occurs on the loopback port when running ELRP on the mirror source port.
EXOS-30320 The debug hal show congestion command throws an error message when executed in show tech-support.
EXOS-30443 An SSH key is not stored in EEPROM on a newly added slot and gets lost on switch reboot.
EXOS-30781

The following error is seen when attempting to download an image when the switch real time clock has a time set that is older than the image being installed:

Error: Failed to download image - Certificates verification failed; Image signature validation will be bypassed.

BGP
EXOS-30280 BGP is not established in user VR if another BGP instance is running on a VRF-type VR.
ExtremeSwitching X695 Series Switches
EXOS-29899 The show configuration command does not display the speed setting of 100G-capable ports.
ExtremeSwitching 5520 Series Switches
EXOS-30085 Packet buffering performance on 5520 is not proper.
EXOS-30243 ExtremeXOS shows an incorrect FEC clause on 5520-VIM-4YE.
Extended Edge Switching
EXOS-30042 Unable to retrieve the slot description via SNMP.
OSPFv2
EXOS-30103 Route tag is not advertised in OSPF redistribution after running the restart ports all command.
SummitStack
EXOS-29778 The CLI session in SummitStack is locked while saving the configuration if the save configuration as-script script-name command was executed previously in the same stack prior to turning on the backup/standby nodes.
EXOS-29835 At random times, the port partition-template configuration is lost after several failovers.
EXOS-29876 With certain triggers occur for a slot that is configured but not operational (for example, executing the show access-list usage acl-slice port port command), the following error message is logged:

Invalid inputs(slot:2, unit:0) to extr_soc_is_xgs3_switch

VLAN
EXOS-24651 An SNMP set on ifAlias OID changes both the display-string and description-string.
EXOS-30109 VLANs with IPv6 addresses are missing the vlan keyword in the show configuration output.
EXOS-30283 DHCP is not enabled on dynamically-created VLANs by ZTP+.
EXOS-30433 IGMP packets are not forwarded when received over network VLAN ports in VXLAN.