The following issues were resolved in ExtremeXOS 31.6. Release 31.6 includes all fixes up to and including the following versions: 11.6.5.3 and earlier, 12.0.5, 12.1.7, 12.2.2-patch1-12, 12.3.6, 12.4.5, 12.5.5, 12.6.3, 12.6.5, 12.7.1, 15.1.5, 15.2.4, 15.3.3, 15.4.1, 15.5.1, 15.5.2, 15.6.1, 15.6.2, 15.7.1, 16.1, 16.1.2, 16.1.3, 21.1, 22.1, 22.2, 22.3, 22.4, 22.5, 22.6, 30.1, 30.2, 30.3, 30.4, 30.5, 30.6, 30.7, 31.1, 31.2, 31.3, 31.4, and 31.5. For information about those fixes, see the release notes for the specific release.
Defect Number | Description |
---|---|
General | |
EXOS-29654 | DHCP Offer and Acknowledgement packets are broadcasted on all sub-VLANs when the switch acts as a relay agent. |
EXOS-30037 | The show ipconfig command output breaks when CLI mode is configured as "non-persistent." |
EXOS-30074 | In a SummitStack with a mirror and the source port in non-master node, a loop occurs on the loopback port when running ELRP on the mirror source port. |
EXOS-30320 | The debug hal show congestion command throws an error message when executed in show tech-support. |
EXOS-30443 | An SSH key is not stored in EEPROM on a newly added slot and gets lost on switch reboot. |
EXOS-30781 |
The following error is seen when attempting to download an image when the switch real time clock has a time set that is older than the image being installed: Error: Failed to download image - Certificates verification failed; Image signature validation will be bypassed. |
BGP | |
EXOS-30280 | BGP is not established in user VR if another BGP instance is running on a VRF-type VR. |
ExtremeSwitching X695 Series Switches | |
EXOS-29899 | The show configuration command does not display the speed setting of 100G-capable ports. |
ExtremeSwitching 5520 Series Switches | |
EXOS-30085 | Packet buffering performance on 5520 is not proper. |
EXOS-30243 | ExtremeXOS shows an incorrect FEC clause on 5520-VIM-4YE. |
Extended Edge Switching | |
EXOS-30042 | Unable to retrieve the slot description via SNMP. |
OSPFv2 | |
EXOS-30103 | Route tag is not advertised in OSPF redistribution after running the restart ports all command. |
SummitStack | |
EXOS-29778 | The CLI session in SummitStack is locked while saving the configuration if the save configuration as-script script-name command was executed previously in the same stack prior to turning on the backup/standby nodes. |
EXOS-29835 | At random times, the port partition-template configuration is lost after several failovers. |
EXOS-29876 | With certain triggers occur for a slot that is configured but not operational
(for example, executing the show access-list usage acl-slice port
port
command), the following error message is logged: Invalid inputs(slot:2, unit:0) to extr_soc_is_xgs3_switch |
VLAN | |
EXOS-24651 | An SNMP set on ifAlias OID changes both the display-string and description-string. |
EXOS-30109 | VLANs with IPv6 addresses are missing the vlan keyword in the show configuration output. |
EXOS-30283 | DHCP is not enabled on dynamically-created VLANs by ZTP+. |
EXOS-30433 | IGMP packets are not forwarded when received over network VLAN ports in VXLAN. |