The following table shows the default settings for ExtremeXOS and Switch Engine starting with version 31.6.
| Feature | 31.6 |
|---|---|
| 1G behavior in 10G ports (5420 and 5520 series switches) | Autoneg OFF for port when 1G optic is inserted in a 10G port |
| Account Lockout | After 3 consecutive login failures, account is locked for 5 minutes. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |
| AVB | Disabled. |
| BFD Strict Session Protection | Disabled. |
| BGP | Disabled. |
| Bluetooth | Enabled. |
| BOOTP Relay | Disabled. |
| CDP | Enabled. |
| Configuration auto save | Disabled. |
| Clear-flow | Disabled. |
| Diagnostics | Admin level privileges required to show diagnostics. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |
| DHCP | Disabled. |
| DNS Cache Resolver and Analytics | Disabled. |
| IPFIX | Disabled. |
| IP NAT | Disabled. |
| EAPS | Disabled. |
| EDP | Enabled on management port. |
| ELRP | Disabled. |
| ESRP | Disabled. |
| Extended Edge Switching (VPEX) | Disabled. |
| ExtremeCloud IQ | Enabled |
| Identity Management | Disabled. |
| IGMP | Enabled, set to IGMPv2 compatibility mode. |
| IGMP Snooping | Enabled. |
| Image Integrity Check | Disabled. |
| IP Route Compression | Enabled. |
| ISIS | Disabled. |
| Log | Admin level privileges required to show log. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |
| Logging memory buffer | Generate an event when the logging memory buffer exceeds 90% of capacity. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |
| MAC Security | Disabled. |
| MLD | Disabled. |
| MLD Snooping | Disabled. |
| MPLS | Disabled. |
| MSRP | Disabled. |
| MSTP | Enabled. |
| NetLogin | All types of authentication are disabled. |
| NTP | Disabled. |
| ONEPolicy | Disabled. |
| Policy rule model | Hierarchical (Unless upgrading from 30.5 with a saved configuration set to access list.) |
| OpenFlow | Not supported. |
| OSPF | Disabled. |
| OVSDB | Disabled. |
| Passwords | Plain text password entry not allowed. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |
| PIM | Disabled. |
| PIM Snooping | Disabled. |
|
PoE Fast PoE Perpetual PoE |
Enabled. Disabled. Disabled. |
| RADIUS | Disabled for both switch management and network login. |
| RIP | Disabled. |
| RMON | Disabled. However, even in the disabled state, the switch responds to RMON queries and sets for alarms and events. |
| sFlow | Disabled. |
| SNMP server | Disabled. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |
| SSH | Disabled. |
| Stacking | — |
| Stacking auto-discovery | Enabled. |
| STP | Enabled. |
| Syslog | Disabled. |
| TACACS | Disabled. |
| Telnet | Disabled. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |
| VPEX IP Multicast Replication | Controlling Bridge |
| VPLS | All newly created VPLS instances are enabled. |
| Watchdog | Enabled. |
| Web HTTP server | Disabled. #GUID-DB53083D-D9CB-4467-8B4D-B4E45D6F0777__A |