ExtremeSwitching Switches Only

On ExtremeSwitching series switches, the output includes the current temperature and operating status of the switch. The following shows a sample display from an ExtremeSwitching switch:

# show temperature
Field Replaceable Units               Temp (C)   Status   Min  Normal  Max
--------------------------------------------------------------------------
Switch         : SummitX               30.00    Normal   -10    0-52  57

The switch monitors its temperature and generates a warning if the temperature exceeds the normal operating range. If the temperature exceeds the maximum limit, the show switch output indicates the switch in an OPERATIONAL (Overheat) mode, and the show temperature output indicates an error state due to overheat.