Stop a PCAP

For SLX devices, you must stop the current uncompleted PCAP before you can begin a new one. 9920 devices support up to 10 running PCAPs before you need to stop one, although you do not need to reach the limit of 10 before stopping a PCAP.

Procedure

  1. In the Navigation menu, select Device Inventory.
  2. In the Devices page, click anywhere in the required device row except the Actions column (Actions column icon) to proceed to the device Overview page.
  3. Select Capture Packets from the Device Actions menu.
  4. Select Configure Port Capture or + (Enable PCAP) as appropriate.
  5. From the Packet Capture actions, select Stop.
  6. Select Delete ( Delete icon ) for the packet capture you wish to stop.
    The packet is removed from the list.