Resolved Issues in ExtremeXOS 16.1.4-Patch1-9

The following issues were resolved in ExtremeXOS 16.1.4-Patch1-9. ExtremeXOS 16.1.4-Patch1-9 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, and ExtremeXOS 16.1.4. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific and Feature Change Requests (CRs) for ExtremeXOS 16.1.4-Patch1-9

CR Number Description
General
xos0064923 When a remote loop is detected by ELRP (ingress and egress port of loop detection is the same) an excessive number of log messages occur.
xos0065654 Etmon process ends unexpectedly with signal 10 when packet size in sampled packet is a negative integer.
xos0065987 Service port FDB entries are learned on physical port of Network VLAN in provider switch.
xos0066444 Kernel error produces "Unable to copy IPMC index" message in MLAG peers with PIM dense mode.
xos0066806 PIM checkpointing loop occurs between two switches that have two ISCs over two VRs.
xos0066874 AAA process is leaking memory when dot1x clients are authenticating frequently.
xos0066895 ELRP process ends unexpectedly when loop is detected in the switch.
xos0066982 In NetLogin dot1x, RADIUS retries are not working properly.
xos0062300 CEP CVID ranges, other than first VLAN, fail when the access port is a trunk.
xos0066012 ExtremeXOS MIBs have non-compilable errors.
xos0066518 LLDP packets are reflected back to the sender without echo kill in PVLAN.
xos0066772 Local multicast fast-path forwarding does not work for a few ports when IGMP filter is in per-VLAN mode.
xos0066891 Packets are being forwarded without a tag after rebooting when PSTAG configured. This issue occurs when VLANs are configured with VID as "1".
xos0066926 Errors occur when configuring OpenFlow in passive mode.
xos0066950

Hash collision error messages may appear when there is contention for the L3 Hash table:

<Warn:Kern.IPv4Adj.Warning> vrId 0 adj 0x00000002 Error finding adjacency when deleting hash collision.
xos0067048 Multicast traffic is not forwarded on PStag ports when port is also added as part of another non-PStag VLAN.
xos0066410 PSU odometer, temperature, and fan information are not updated periodically in the chassis-based switches.
xos0066774 IPv6 flow redirect does not work after slot is disabled, and then enabled again.
xos0057796 Power is momentarily denied to PoE devices connected on ports when a redundant PSU is inserted.
xos0065845 Traffic drops between the CVID configured ports in the VPLS service VMAN when CEP egress filtering is enabled.
Summit X670 Series Switches
xos0066406 Scaled PStag configuration with non-PStag VLANs causes PStag error messages and installation of additional IPMC rules.
NWI Switches
xos0066301 Transceiver is not detected on NWI platforms.
Summit X460 Series Switches
xos0065763 Front panel port is not receiving any traffic over a period of time when devices are plugged in.
SummitStack
xos0065756 In SummitStacks, alternate IP address is used for external communication even though a Management IP address is configured.
xos0066085 Restart of some processes does not work properly when the standby slot has a lower license level.
xos0066104 In SummitStacks, memory leak occurs in backup slot when configuring LLDP to advertise power-via-mdi with classification.
xos0066423 In SummitStacks, with policy re-authentication and continuous MAC move scenarios, ACL delete requests are failing in backup node.
BlackDiamond 8800 Series Switches
xos0065366 On BlackDiamond 8800 series switches, run diagnostics fails when it runs on both MSMs simultaneously.