Resolved Issues in ExtremeXOS 16.1.3-Patch1-11
The following issues were resolved in ExtremeXOS 16.1.3-Patch1-11. ExtremeXOS 16.1.3-Patch1-11 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3 and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0055511 |
While configuring STP (802.1d) with port-encapsulation mode as EMISTP where the L2PT-enabled VMAN and access VLAN have the same tag, the designated bridge is not accepting the L2PT tunneled BPDUs from the root bridge, and thus causes a loop (designated bridge also becomes a root bridge). This problem does not occur:
|
xos0064023 | L3 table full log appears because of false resource full triggered by link flaps. |
xos0064114 | SNMP process ends unexpectedly with signal 6 after running the switch for a long time. |
xos0064232 | On Summit X670-G2 and X770 series switches, after changing a VPWS service VLAN tag, traffic continues to be forwarded with the prior tag. |
xos0064423 | In BlackDiamond 8800 and X8 series switches, flooding to a VPLS peer does not work after adding a new port to an existing LAG group. |
xos0064523 | Dynamic ACL rule is not removed properly when turning off packet capture. |
xos0064525 | Policy does not allow regular expression to be specified for BGP communities. |
xos0064568 | After slot reboot, traffic drop occurs on VPLS service VLAN LAG port. |
xos0064575 | "Operation draining timed out" error message appears while saving the configuration in stacking switch. |
xos0064671 | OSPFv3 incorrectly chooses higher path cost for a route based on the lower LS age. |
xos0064735 | VMAN CEP configuration gets removed from hardware while removing member port from LAG. |
xos0064831 | With a switch connected to two RADIUS servers (one for Netlogin and one for management access), the Netlogin RADIUS server is incorrectly chosen for switch web access. |
xos0064884 | "remove-private-AS-numbers" setting in BGP is not preserved after switch reboot. |
xos0064909 | Traffic loss occurs while changing and reverting the base VID of VLANs with PSTag ports. |
xos0064910 | Following error messages appear while changing and reverting back the base VLAN
tag of VLANs with PSTag ports:
<Erro:Kern.MPLS.Error> MPLS bcm_esw_mpls_port_match_vlan_del failed for unit = 0, port = 0xffffffff vp = 0xe, match_vlan = 0 match_inner_vlan = 0, rv = -7 (Entry not found) |
xos0064956 | EDP neighbors are not displayed when remote mirroring is disabled or after unconfiguring a monitor port of remote mirroring. |
xos0064960 | Multicast traffic is forwarded through MVR receiver port in a VLAN even if there is no active receiver. |
xos0065073 | Kernel oops observed when IPv6 duplicate address detected in the switch. |
xos0065189 | BGP secondary best path is not active when primary best path goes down. |
xos0065261 | Traffic loss occurs in one VLAN when another VLAN with a loop causes significant congestion. |
xos0065291 | One-to-many mirroring is not working. |
xos0065292 | Traffic is not forwarded from member VLAN to untagged ports in translation VLAN. |
Summit X460-G2 Series Switches | |
xos0064684 | On Summit X460-G2 series switches, ESVT test does not start if the loopback port used is a 10G port. |
Summit X670-48X Series Switches | |
xos0064855 | On Summit X670-48X switches, some ports do not become active when using 5 M SFP+ passive copper cable connected to Summit X45-0G2 series switches. |