Resolved Issues in ExtremeXOS 16.1.3-Patch1-2
The following issues were resolved in ExtremeXOS 16.1.3-Patch1-2. ExtremeXOS 16.1.3-Patch1-2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0057785 | STP domain tag is removed when all ports are deleted from STP auto-bind enabled-VLANs. |
xos0061745 | Ampersand used in UPM script is replaced by “& amp” in the XSF configuration. |
xos0062850 | When upgrading ExtremeXOS to 15.7 or later releases, the web HTTP access is enabled even though it is disabled in the configuration. |
xos0063134 | Traffic stops after disabling, and then enabling LAG porst having pstag with static FDB. |
xos0063173 | Process dcbgp ends unexpectedly with signal 11 after issuing the command show bgp neighbor. |
xos0063186 | Kernel oops occurs when deleting private VLAN. |
xos0063240 | ACL process ends unexpectedly when switch has clear-flow ACL rule with count interval greater than snmptrap generation timer. |
xos0063245 | With IGMP per-VLAN mode, VRRP flaps occur after adding tagged ports to VLANs. |
xos0063258 | OSPFv3 routes are not updated in routing tables if there is a delay in receiving LSAs. |
xos0063282 | ExtremeXOS CLI restricts PVLAN subscriber VLAN from being configured as an EAPS-protected VLAN. |
xos0063418 | "No mapping for Modid" errors occur when sFlow is enabled on the port. |
xos0063423 | Memory leak occurs in ISIS process when exporting OSPF routes to ISIS. |
xos0063429 | The output of the command show fan shows the fan status as empty after a hot re-seating of the fan module. |
xos0063457 | Configuration for adding network VLAN port in STP for subscriber is not saved. |
xos0063465 | Cannot add/delete ports to load-shared MLAG ports without disabling MLAG. |
xos0063478 | Traffic drop occurs while adding new member port to the existing LAG group and PSTAG is configured on the port. |
xos0063484 | Enhancement added in STP flush generation mechanism to reduce hardware programming load. |
xos0063493 | Traffic stops after disabling, and then enabling LAG ports in VPLS service VLAN with static FDB. |
xos0063585 | AAA process ends unexpectedly when NetLogin primary RADIUS server is down and "Active directory domain services" alone is down in secondary NetLogin RADIUS server. |
xos0063673 | If one MAC address learned on the same port in a dynamic VLAN ages out, the whole dynamic VLAN is deleted after 20 seconds even though other MAC addresses are still in the FDB table. |
xos0063710 | Kernel oops occurs on switch with Private VLAN and MLAG configuration after executing restart ports all. |
xos0063736 | In Syslog, username information appears as "*****" during login/logout cases. |
xos0063815 | Traffic is dropped on one VPLS instance when another VPLS instance running on same switch is deleted. |
xos0063853 | Potential memory corruption when MAC locking is configured. |
xos0063870 | Kernel oops occurs due to memory overrun in user kernel interface. |
xos0063956 | ACL slice is not freed up after changing IGMP snooping filter from per-vlan to per-port mode. |
xos0054714 | When ACLs are applied in both ingress and egress directions, you cannot see egress direction using SNMP. When a policy has more than one counter, using SNMP, you can only check the updates from the first counter, and subsequent counters do not appear. |
xos0059481 | Static FDB is programmed incorrectly in hardware after a stack failover. |
xos0062902 | Kernel oops occurs while disabling service VMAN with CEP configuration. |
xos0063521 | A few IBGP routes are not updated in routing table when disable bgp and enable bgp commands are executed in quick succession. |
xos0063547 | Process ACL ends unexpectedly after applying a policy file with source zone as a match condition. |
xos0063644 | exsshd process ends unexpectedly with signal 11 in rare scenarios. |
xos0063814 | UPM process ends unexpectedly with Signal 11 occasionally when UPM timers are configured. |
xos0063365 | Frequent MLAG bulk syncs observed due to checksum mismatch between MLAG peers when ISC port was added as an untagged port to a tagged VLAN and VRRP was running between the peers. |
BlackDiamond 8800 Series Switches | |
xos0063552 | Backup Master Switch Fabric Module (MSM) fails to reach 'In sync' state after bootup in fully loaded chassis with a large number of ACL rules applied. |
xos0063614 | Kernel crash occurs when receiving DHCP packets with invalid field values. |
xos0063872 | After multiple executions of run failover with redirect-flow configuration, IPv4 ping fails. |
xos0063333 | In BlackDiamond 8800 series switches, optics information is not detected and ports remain in "Ready" state after reboot. |
BlackDiamond X8 Series Switches | |
xos0057363 | Sample message with invalid slot ID received after enabling sFlow. |
xos0063928 | In BlackDiamond X8 series switches, Sysuptime in sFlow packets is invalid. |
E4G 400 Cell Site Routers | |
xos0063370 | PTP Delay Response correction field has high value (Junk value) when PTP Delay response packets were passing through combo ports. |
SummitStack | |
xos0061777 | Standby nodes do not come back up to operational state after they go into failed state. |
xos0062853 | Communication failure occurs between hosts connected to SummiStack after the stack is broken into two separate stacks, and then merged back to single stack. |
xos0063490 | CFM stays down after slot reboot on a stack. |
xos0063788 | The following error appears continuously in backup/standby nodes when node is put
in the failed state due to a license/ExtremeXOS mismatch:
&ltErro:DM.Error&gt Slot-2: Node State[185] = FAIL (License Mismatch) |
Summit X450-G2 Series Switches | |
xos0060129 | On Summit X450-G2 series switches, 10/100/1000BASE-T SFP+ optics do not link to similar optics when in the SFP/SFP+ ports. They do link or partially link when connected to a regular triple speed copper port. |
Summit X460 Series Switches | |
xos0063595 | On Summit X460 series switches, the command to configure stacking ports does not show the native option. |
Summit X460-G2 Series Switches | |
xos0062913 | On Summit X460-G2 series switches, copper combo port does not advertise its flow control capabilities to peers. |
xos0063495 | Policy authentication fails when radius request queue has stale entries. |
xos0063927 | Error "Deferred L2 notification code out of sync unit 0" repeatedly appears in log. |
Summit X670 Series Switches | |
xos0057671 | Link status goes to Ready state on port with 10/100/1000BASE-T optics after multiple reboots. |
Summit X670-G2 Series Switches | |
xos0063665 | When Tenant VM connected to MLAG (LACP) ports is turned off, tenant VM FDB is not aged out even after the age out timer expires. The FDB entry persists. |
xos0063807 | On Summit X670-G2 series switches, egress ACL rule actions do not take effect on ports 64-72 |