Resolved Issues in ExtremeXOS 30.3

The following issues were resolved in ExtremeXOS 30.3. ExtremeXOS 30.3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, and ExtremeXOS 30.2. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.3

CR Number Description
General
xos0069194 Packets with size greater than the configured IP-MTU value are forwarded if jumbo frames is enabled and ARP is resolved.
xos0069987 HAL process ends unexpectedly with signal 11 when executing the command that fetches entries from hardware.
xos0072228 Interface flags in the show ipconfig output do not match the flag values in the show ipconfig vlan-name output.
xos0073899 LACP sharing enabled port are added to link aggregator even though port speeds are different.
xos0074117 When a network is unreachable, ICMPv6 destination unreachable packets are not returned and IPv6 "InNoRoutes", ICMPv6 “DestUnreachs” Out counters are not incremented as shown in the show ipstats ipv6 vlan commmand.
xos0074200 The OPNEXT transceiver device does not link reliably on ExtremeSwitching X690, X590, and X465 series switches.
xos0074661 The commands enable switch usb and disable switch usb stopped working in the ExtremeXOS 30.1 release.
xos0074702 Zero Touch Provisioning (ZTP) does not work over the Management interface.
xos0074751 The command clear port <port_list> rate-limit flood out-of-profile status should clear status only.
xos0074871 EMS log message should be generated when a port cannot be added to a VLAN.
xos0074872 When limit learning is configured on one VLAN, FDB entries on another VLAN are flushed from hardware.
xos0074874 Need to permit the use of few special characters for SysName/SysLocation/SysContact.
xos0074933 Dynamic VLANs created by MVRP on MLAG ports flap continuously when the ports are in the down state.
xos0075012 Need additional configurable option for success count in flow-redirect health check command.
xos0075021 HAL process ends unexpectedly when unsupported optics are inserted into the switch.
xos0075096 SNMPwalk does not return "partinfo" of all fans present in the switch.
xos0075175 After reboot, ports are sometimes not added to the aggregator.
xos0075202 Saving the configuration is failing due to IPFIX process.
xos0075213 If the debug command debug hal show ipv4Adj is interrupted using "Q" or Ctrl-C before all adjacencies appear, then subsequent Layer 3 hardware updates do not occur. Reboot is necessary to recover.
xos0075263 In stacking, LACP ports present in back-up slot are removed/re-added when PSTAG is configured.
xos0075283 Enabling NTP from within the VRF is allowed even though it is not supported.
xos0075433 Ethernet OAM Rx packet counter does not increment on ExtremeSwitching X465, X590, X690, and X870 series switches.
xos0075483 The process cfgmgr ends unexpectedly when executing another save command after a failing first save command.
xos0075510 Need to add success option under to command configure flow-redirect next-hop in the ExtremeXOS documentation.
xos0075937 Executing Python script produces an ImportError error message when importing files from same directory.
ExtremeSwitching X465 Series Switches
xos0074426 On ExtremeSwitching X465 series switches with 60W and 90W PoE ports, front panel ports do not match the port numbering on the PoE board. The port number pairs are swapped. The default disconnect precedence is 'deny port' where the highest numbered ports are denied power when the switch's allocated power exceeds its PoE budget.
xos0075001 When a slot on a X465 stack with 25G VIM is unconfigured, the ports come up in 40G mode and errors are logged.
xos0075191 Layer 2 traffic is not forwarded through the redundant ports between ExtremeSwitching X465 stack and X465 standalone switch.
ExtremeSwitching X690 Series Switches
xos0073818 Packets originating in a switch fail to egress after removing the ports from service VLAN.
ExtremeSwitching X870 Series Switches
xos0073426 Unable to configure FEC on X870-96x-8c switch on ports with100G capability enabled through a license.
ExtremeSwitching X440-G2 Series Switches
xos0075020 Switch takes around 30 seconds to bring up all ports, which is triggering multiple STP topology changes.
xos0075030 On ExtremeSwitching X440-G2 48-port switches, ACL hardware full errors occur when Extreme Management Center (XMC) is used to push policy and telemetry.
xos0075129 IPv6 MLD packet filter installation fails in ACL double-width mode.
xos0075492 ExtremeSwitching X440-G2 series switches PoE virtual temperature sensor model algorithm needs correction.
Summit X460-G2 Series Switches
xos0075787 Port stays in the loop-back state after upgrading the standalone switch to stack.
ACL
xos0074626 In Policy, traffic is flooded on ports even after removed from the redirect-port-list action modifier.
xos0075854 If "ipmcforwarding iPv6" is enabled, then the installation of an ACL with "arp-sender-address" match condition fails.
AVB
xos0075529 Member port of a share group becomes AVB-incapable after tearing down the share group and re-creating it.
Clocking
xos0075437 Random values are added to GPTP packets.
ELRP
xos0074513 Ports disabled by ELRP due to a loop in the dynamic VLAN of NetLogin is not automatically re-enabled after timer expiry.
   
EVPN
xos0071878 With Auto-peering/EVPN configuration, upgrading to ExtremeXOS 30.x from releases earlier than 30.1 produces error messages that are actually informational:
04/19/2018 08:58:47.57 <Erro:FDB.ArpError> ipv6_neighbour_conf_t_set# Error Ignoring user VR(vrid-3) IPv6 neighbor pending entries (1024)
 04/19/2018 08:58:47.57 <Erro:FDB.ArpError> ipv6_neighbour_conf_t_set# Error vr-purple - Ignoring Ipv6 Neighbour entries (4096)
 04/19/2018 08:58:47.48 <Erro:FDB.ArpError> arp_config_t_set# Error Ignoring user VR(vrid-3) ARP proxy entries (256)
 04/19/2018 08:58:47.48 <Erro:FDB.ArpError> arp_config_t_set# Error Ignoring user VR(vrid-3) ARP pending entries (256)
 04/19/2018 08:58:47.48 <Erro:FDB.ArpError> arp_config_t_set# Error vr-purple - Ignoring ARP entries (8192)

These messages inform you that user-VR based ARP limits configured in previous versions of ExtremeXOS are ignored from 30.x onward, and that ARP limits are derived from global configured ARP limits.

Extended Edge Switching
xos0073946 On Extended Edge Switching controlling bridge (CB) switches, the show inline-power stats command takes longer than usual to display the output, and sometimes it returns "Timeout occurred while retrieving information from hardware." messages.
xos0075689 Switch becomes unresponsive for 5–15 minutes when UPM executes command in orchestration mode on both MLAG controlling bridges.
MAC Security (MACsec)
xos0075817 Incorrect error message appears when an ASCII string without 0x prefix is configured as the CAK.
xos0075837 If you use an .xsf script file to apply MACsec configuration and the commands to configure the optional MACsec parameters (include-sci, mka actor-priority, etc.) are listed before the command to enable MACsec, these optional MACsec parameters are not applied unless you run the initialization command. Standard configuration files (.cfg) are not affected by this issue.
xos0075691

When MACsec is enabled on the same port that the MACsec Key Agreement (MKA) protocol will run on, if the local port is elected Key Server (KS), and the MACsec peer does not install and use a freshly distributed Secure Association Key (SAK) prior to its next MKPDU transmission, then the connection might never reach the secure state causing all traffic to be blocked.

This issue occurs when inter-operating with third-party MACsec devices, and between ExtremeXOS devices when reconfiguring the cipher suite on multiple ExtremeXOS ports (for example, cipher suite from GCM-AES-128 to GCM-AES-256).

Mirroring
xos0075204 Mirroring a port to a remote IP address is not working on ExtremeSwitching X440-G2 series switches. Port+VLAN mirroring is not affected.
MLAG
xos0074601 Ping is not working on MLAG port of a mixed stack of Summit X460-G2 and ExtremeSwitching X620 series switches if Summit X460-G2 is the master.
xos0075872 Traffic loss occurs for more than 20 seconds when controlling bridge is rebooted or when you disable/enable ISC cascade port.
xos0075939 Enabling MLAG on a port in NP state causes traffic issues.
MPLS
xos0074611 Label mismatch issues between LDP routers after enabling LDP loop detection.
xos0074924 VPLS: VP leak occurs when switching pseudowire path from RSVP to LDP and vice versa.
xos0075683 VC label TTL has not been set correctly in VPLS.
Network Login
xos0074606 NetLogin users are authenticated to random destinations when destination VLAN attributes from the RADIUS server are not received.
Policy
xos0066643 NetLogin session is not cleared in session timeout when session timeout is received from RADIUS attribute.
xos0074910 Captive portal stops working when more clients try to access the captive portal page.
xos0075057 Traffic drop occurs when receiving LLDP packets on the ONEPolicy admin profile configured port.
xos0075544 Policy process ends unexpectedly at random time, when client in the network tries to access captive portal page.
Security
xos0072784

Policy does not currently apply NSI in hardware for static and/or dynamic admin-profile configurations. Netlogin does not currently allow a port to be enabled if VXLAN is configured on the port.

Note: For VXLAN, errors still occur for ports where policy is not active on that port, when policy is globally enabled.
SNMP
xos0074806 SNMP walk fails when trap receiver is configured using SNMP community strings starting with “v,w,x,y,z".
Stacking
xos0074952 Stack remains in listening state if both native and alternate ports are configured without inserted native port.
STP
xos0074481 All participating VLANs are removed from STP after deleting one port + VLAN from the STP domain.
xos0076081 Backup root needs to be triggered for root expiry.