The following issues were resolved in ExtremeXOS 33.3.1. Version 33.3.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, 32.6.x, 32.7.x, 33.2.1, and 33.3.1.
| Defect Number | Description |
|---|---|
| General | |
| CFD-11140 | STP flag is not removed from VLAN even though the VLAN is no longer part of the STP domain. |
| CFD-11925 | SNMP stops responding briefly after sending two consecutive save config snmpset. |
| CFD-12017 | Randomly ports do not become active when multiple ports using tri-speed BaseT optics are coming up at the same time. |
| CFD-12698 | SNMP timeout was seen after enabling device and port statistics in ExtremeCloud IQ - Site Engine. |
| CFD-12788 | Switch crashes when the internal dynamic VLAN counter becomes 0 |
| CFD-12837 | ARP entry is not properly learned when a host moves from a sub-VLAN to another sub-VLAN. |
| CFD-12888 | After copying an ems filter having strict match conditions to a new ems filter, Climaster process crash occurs while executing the show configuration ems command. |
| CFD-12904 | ELRP Dynamic VLAN interval timers does not work. |
| CFD-12966 | While fetching optic information for bidirectional GBICs for CLI, the output displays opposite directions than intended one. |
| CFD-12999 | Restrictions are needed in CLI such that it should not accept policy name that has special characters. |
| CFD-13111 | Upgrading the switch through Chalet fails. |
| CFD-13134 | When a switch receives IGMP packet on its to-port of remote-mirroring, and if the packet tag matches the remote-mirroring tag, the switch sends back the same packet on the received port. |
| CFD-13139 | The show tech command doesn't capture VLAN information if collected immediately after factory default start. |
| CFD-13178 | Memory leak in expy3 process while polling LLDP information that contains a custom TLV with subtype 0. |
| CFD-13218 | NAC client IP is listed backward when it is resolved using Identity Management. |
| CFD-13253 | A new telnet session couldn't be created on the switch when the software is being installed. |
| CFD-13298 | BFD flag/config is not reset when running disable bfd vlan and unconfigure bfd vlan commands. |
| CFD-13299 | Getting an error "Command parse token stack overflow" while using tab in the command show iproute ipv4. |
| CFD-13473 | Can't exit out of show ports vlan statistics no-refresh command output. |
| CFD-13554 | SNMP trap VR configuration is applied incorrectly when it is done using SNMPSet operation. |
| CFD-13576 | Process rtmgr crashes with signal 11 leading to switch restart. |
| SummitStack | |
| CFD-11560 | The mixed OS stack can be upgraded with a non ".lst" file. |
| CFD-12099 | When a slot boots up in a stack, SNMP traps are generated for ports even though those ports are marked as not present in the slot. |
| CFD-12699 | EDP process crash occurs when executing [extremeEdpNeighborTable|https://mibs.observium.org/mib/EXTREME-EDP-MIB/#extremeEdpNeighborTable] table. |
| CFD-13128 | Memory depletion in the backup node due to a memory leak in the LLDP process. |