Note
X440-G2, X450-G2, and X460-G2 are not supported in this version.| Metric | Product | Limit |
|---|---|---|
| AAA (local)—maximum number of admin and local user accounts. | All platforms, except X435 | 16 |
| Access lists (meters)—maximum number of meters. | ExtremeSwitching X465 | 2,048 ingress 512 egress |
| ExtremeSwitching X695 | 6,000 ingress 2,000 egress | |
| Access lists (policies)—suggested maximum number of lines in a single policy file. | All platforms, except X435 | 300,000 |
| Access lists (policies)—maximum number of rules in a single policy file.a | ExtremeSwitching X465, X695 | 8,192 ingress 1,024 egress |
| Access lists (policies)—maximum number of rules in a single policy file in first stage (VFP). | ExtremeSwitching, X465 | 2,048 ingress only |
| ExtremeSwitching X695 | 1,024 ingress only | |
| Access lists (slices)—number of ACL slices. | ExtremeSwitching X465, X695 | 12 ingress 4 egress |
| Access lists (slices)—number of ACL slices in first stage (VFP). | ExtremeSwitching X465, X695 | 4 ingress only |
| ACL Per Port Meters—number of meters supported per port. | ExtremeSwitching, X465, X695 | 16 |
| ACL port ranges. | ExtremeSwitching, X465, X695 | 32 |
| Meters Packets-Per-Second Capable. | ExtremeSwitching, X465, X695 | Yes |
| AVB (audio video bridging)—maximum number of active streams. | ExtremeSwitching X465, X695 | 4,096 |
| BFD sessions (Software Mode)—maximum number of BFD sessions. | ExtremeSwitching, X465, X695 (default timers—1 sec) | 512 |
| ExtremeSwitching, X465, X695 (minimal timers—100 msec) | 10c | |
| BFD IPv4 sessions (Hardware Assisted)—maximum number of IPv4 BFD sessions. | ExtremeSwitching, X465, X695 | 900 (PTP not enabled) 425 (PTP enabled) 256 (with 3 ms transmit interval) |
| BFD IPv6 sessions (Hardware Assisted)—maximum number of IPv6 BFD sessions. | ExtremeSwitching, X465, X695 | 425 (PTP not enabled) |
| BOOTP/DHCP relay—maximum number of BOOTP or DHCP servers per virtual router. | ExtremeSwitching X465, X695 | 8 |
| BOOTP/DHCP relay—maximum number of BOOTP or DHCP servers per VLAN. | ExtremeSwitching X465, X695 | 8 |
| BOOTP/DHCP relay—maximum number of DHCPv4/v6 relay agents | ExtremeSwitching X465, X695 | 4,000 |
| Connectivity
fault management (CFM)—maximum number or CFM domains. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 8 |
| CFM—maximum
number of CFM associations. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 256 |
| CFM—maximum
number of CFM up end points. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 32 |
| CFM—maximum number of CFM down end points. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 32 |
| CFM—maximum
number of CFM remote end points per up/down end point. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 2,000 |
| CFM—maximum
number of dot1ag ports. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 128 |
| CFM—maximum
number of CFM segments. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 1,000 |
| CFM—maximum
number of MIPs. Note: With Advanced Edge license or higher.
| ExtremeSwitching, X465, X695 | 256 |
| CLEAR-Flow—total number of rules supported. The ACL rules plus CLEAR-Flow rules must be less than the total number of supported ACLs. | ExtremeSwitching X465, X695 | 8,192 |
| Data Center Bridging eXchange (DCBX) protocol Type Length Value (TLVs)—maximum number of DCBX application TLVs. | ExtremeSwitching, X465, X695 | 8 |
| DHCPv6 Prefix Delegation Snooping—Maximum number of DHCPv6 prefix delegation snooped entries. | ExtremeSwitching, X465, X695 | 256 (with underlying protocol RIPng) 128 (with underlying protocol OSPFv3) 1,024 (with static routes) |
| DHCP snooping entries—maximum number of DHCP snooping entries. | ExtremeSwitching, X465, X695 | 2,048 |
| Dynamic ACLs—maximum number of ACLs processed per second.
Note: Limits are load-dependent.
| ExtremeSwitching, X465, X695 | |
|
| |
| EAPS
domains—maximum number of EAPS domains. Note: An EAPS ring that is being spatially reused cannot have
more than four configured EAPS domains.
Note: You can increase the number of domains by upgrading to the
Advanced Edge license.
| ExtremeSwitching, X465, X695 | 4 |
| EAPSv1 protected VLANs—maximum number of protected VLANs. | ExtremeSwitching X465, X695 | 2,000 |
| ERPS
domains—maximum number of ERPS domains with or without CFM
configured. Note: You can increase the number of domains by upgrading to the
Advanced Edge license.
| ExtremeSwitching, X465, X695 | 4 |
| ERPSv1 protected VLANs—maximum number of protected VLANs. | ExtremeSwitching X465, X695 | 2,000 |
| ERPSv2 protected VLANs—maximum number of protected VLANs. | ExtremeSwitching, X465, X695 | 2,000 |
| ELSM (vlan-ports)—maximum number of VLAN ports. |
ExtremeSwitching, X465, X695 | 5,000 |
| Extended Edge Switching maximum BPEs—maximum number of attached bridge port extenders (BPEs). | ExtremeSwitching X465 | 48 |
| Extended Edge Switching maximum cascade ports—maximum number of upstream ports on bridge port extenders (BPEs). | ExtremeSwitching X465 |
2 on V400-24 and V300 models 4 on V400-48 models |
| Extended Edge Switching maximum tiers—maximum number of cascade levels (tiers) of bridge port extenders (BPEs). | ExtremeSwitching X465 | 4 (except for V300-8P-2T-W, which support 1 tier) |
| Extended Edge Switching maximum ring BPEs—maximum number of bridge port extenders (BPEs) in a ring topology. | ExtremeSwitching X465 | 8 |
| Extended Edge Switching maximum VLANs—maximum number of VLANs - Includes all VLANs | ExtremeSwitching X465 | 4,094 |
| Extended Edge Switching VLAN+ port memberships—maximum number of VLAN+ (extended) port memberships. | ExtremeSwitching X465 |
12,000 in hash mode (default) 131,000 in port-group mode |
| Forwarding rate—maximum L3 software forwarding rate. | ExtremeSwitching X465 | 28,497 pps |
| ExtremeSwitching X695 | 34,813 pps | |
| FDB (unicast blackhole entries)—maximum number of unicast blackhole FDB entries. | ExtremeSwitching X465 | 278,528f |
| ExtremeSwitching X695 | 294,912 f | |
| FDB (multicast blackhole entries)—maximum number of multicast blackhole FDB entries. | ExtremeSwitching X465, X695 | 4,096 |
| FDB (maximum L2 entries)—maximum number of MAC addresses. | ExtremeSwitching X465 | 278,528g |
| ExtremeSwitching X695 | 294,912 g | |
| FDB (maximum L2 entries)—maximum number of multicast FDB entries. | ExtremeSwitching X465, X695 | 4,096 |
| Identity management—maximum number of Blacklist entries. | ExtremeSwitching, X465, X695 | 512 |
| Identity management—maximum number of Whitelist entries. | ExtremeSwitching, X465, X695 | 512 |
| Identity management—maximum number of roles that can be created. | ExtremeSwitching, X465, X695 | 64 |
| Identity management—maximum role hierarchy depth allowed. | ExtremeSwitching, X465, X695 | 5 |
| Identity management—maximum number of attribute value pairs in a role match criteria. | ExtremeSwitching, X465, X695 | 16 |
| Identity management—maximum number of child roles for a role. | ExtremeSwitching, X465, X695 | 8 |
| Identity management—maximum number of policies/dynamic ACLs that can be configured per role. | ExtremeSwitching, X465, X695 | 8 |
| Identity management—maximum number of LDAP servers that can be configured. | ExtremeSwitching, X465, X695 | 8 |
| Identity management—maximum number of Kerberos servers that can be configured. | ExtremeSwitching, X465, X695 | 20 |
| Identity management—maximum database memory size. | ExtremeSwitching, X465, X695 | 512 |
| Identity
management—recommended number of identities per switch.
Note: Number of identities per switch is for a default identity
management database size (512 Kbytes) across all platforms.
| ExtremeSwitching, X465, X695 | 100 |
| Identity
management—recommended number of ACL entries per identity.
Note: Number of ACLs per identity, based on system ACL
limitation.
| ExtremeSwitching, X465, X695 | 20 |
| Identity management—maximum number of dynamic ACL entries configured as an individual dynamic rule, or as an ACL entry in a policy file. | ExtremeSwitching, X465, X695 | 500 |
| IGMP snooping per VLAN filters—maximum number of VLANs supported in per-VLAN IGMP snooping mode. | ExtremeSwitching X695 | 1,500 |
| ExtremeSwitching X465 | 4,000 | |
| IGMPv1/v2 SSM-map entries—maximum number of IGMPv1/v2 SSM mapping entries. | ExtremeSwitching, X465, X695 | 500 |
| IGMPv1/v2 SSM-map entries—maximum number of sources per group in IGMPv1/v2 SSM mapping entries. | ExtremeSwitching, X465, X695 | 50 |
| IGMPv2 subscriber—maximum number of IGMPv2 subscribers per port.n | ExtremeSwitching X465, X695 | 4,000 |
| IGMPv2 subscriber—maximum number of IGMPv2 subscribers per switch.n | ExtremeSwitching X465, X695 | 45,000 |
| IGMPv3 maximum source per group—maximum number of source addresses per group. | ExtremeSwitching, X465, X695 | 250 |
| IGMPv3 subscriber—maximum number of IGMPv3 subscribers per port.n | ExtremeSwitching, X465, X695 | 4,000 |
| IGMPv3 subscriber—maximum number of IGMPv3 subscribers per switch.n | ExtremeSwitching X465, X695 | 45,000 |
| IP
ARP entries in software—maximum number of IP ARP entries in
software. Note: Might be limited by hardware capacity of FDB (maximum L2
entries).
| ExtremeSwitching X465 | 157,694 (up to) h |
| ExtremeSwitching X695 | 184,318 (up to) h | |
| IPv4 ARP entries in hardware with minimum LPM routes—maximum recommended number of IPv4 ARP entries in hardware, with minimum LPM routes present. Assumes number of IP route reserved entries is 100 or less. | ExtremeSwitching X465 | 119,000 (up to) h |
| ExtremeSwitching X695 | 146,000 (up to) h | |
| IPv4 ARP entries in hardware with maximum LPM routes—maximum recommended number of IPv4 ARP entries in hardware, with maximum LPM routes present. Assumes number of IP route reserved entries is “maximum.” | ExtremeSwitching X465 | 109,000 (up to) h |
| ExtremeSwitching X695 | 125,000 (up to) h | |
| IP flow information export (IPFIX)—number of simultaneous flows. | ExtremeSwitching, X465, X695 | N/A |
| IPv4 remote hosts in hardware with zero LPM routes—maximum recommended number of IPv4 remote hosts (hosts reachable through a gateway) in hardware when LPM routing is not used. Assumes number of IP route reserved entries is 0, and number of IPv4 ARP entries present is 100 or less. | ExtremeSwitching X465 | 216,000 (up to) h |
| ExtremeSwitching X695 | 241,000 (up to) h | |
| IPv4 routes—maximum number of IPv4 routes in software (combination of unicast and multicast routes), including static and from all routing protocols. | ExtremeSwitching X465, X695 | 131,000 |
| IPv4 routes (LPM entries in hardware)— number of IPv4 routes in hardware. | ExtremeSwitching X465, X695 | 131,000 q |
| IPv6 6in4 tunnel—maximum number of IPv6 6in4 tunnels. | ExtremeSwitching X465, X695 | 255 |
| IPv6 6to4 tunnel—maximum number of IPv6 6to4 tunnels. | ExtremeSwitching, X465, X695 | 1 (per virtual router) |
| IPv6 addresses on an interface—maximum number of IPv6 addresses on an interface. | ExtremeSwitching, X465, X695 | 255 |
| IPv6 addresses on a switch—maximum number of IPv6 addresses on a switch. | ExtremeSwitching, X465, X695 | 2,048 |
| IPv6 host entries in hardware—maximum number of IPv6 neighbor entries in hardware. | ExtremeSwitching X465 | 24,500 s |
| ExtremeSwitching X695 | 57,000 h | |
| IPv6 routes in software—maximum number of IPv6 routes in software, including static routes and routes from all routing protocols. | ExtremeSwitching X465, X695 | 65,000q |
| IPv6 routes (LPM entries in hardware)—maximum number of IPv6 routes in hardware. | ExtremeSwitching X465, X695 |
65,000q |
| IPv6 routes with a mask greater than 64 bits in hardware—maximum number of such IPv6 LPM routes in hardware. | ExtremeSwitching X465, X695 | 8,192r |
| IPv6 route sharing in hardware—route mask lengths for which ECMP is supported in hardware. | ExtremeSwitching X465, X695 | 0–128r |
| IP router interfaces—maximum number of VLANs performing IPv4 and/or IPv6 routing. Excludes sub-VLANs. | ExtremeSwitching, X465, X695 | 2,048 |
| IP multicast static routes—maximum number of permanent multicast IP routes. | ExtremeSwitching, X465, X695 | 1,024 |
| IP unicast static routes—maximum number of permanent IP unicast routes. | ExtremeSwitching, X465, X695 | 1,024 |
| IP route sharing (maximum gateways)—Configurable maximum number of gateways used by equal cost multipath OSPF, BGP, IS-IS, static routes, or L2VPNs. Static routes, OSPF, and BGP are limited to 64 ECMP gateways per destination, while IS-IS is limited to 8. L2VPNs are limited to 16 LSPs per pseudowire on platforms that support 32 gateways, and 64 LSPs per pseudowire on platforms that support 64 gateways. | ExtremeSwitching, X465, X695 | 2, 4, 8, 16, 32, or 64 |
| IP route sharing (total combinations of gateway sets)—maximum number of combinations of sets of adjacent gateways used by multipath OSPF, BGP, IS-IS, or static routes. |
|
|
| ExtremeSwitching X465, X695 | ||
Note: The values here represent the maximum attainable ECMP
groups of which, due to the RIOT feature, half are reserved for overlay and half for underlay
routing. For more information about RIOT, see ExtremeXOS v34.1.1 User Guide
.
|
| |
|
| |
| IP multinetting (secondary IP addresses)—maximum number of secondary IP addresses per VLAN. | ExtremeSwitching, X465, X695 | 255 |
| Jumbo frames—maximum size supported for jumbo frames, including the CRC. | ExtremeSwitching, X465, X695 | 9,216 |
| Layer-2 IPMC forwarding caches—(IGMP/MLD/PIM snooping) in
mac-vlan mode. Note:
| ExtremeSwitching X695 | 73,000 |
| ExtremeSwitching X465 | 67,000 | |
| Layer-3 IPv4 Multicast—maximum number of <S,G,V>
entries installed in the hardware (IP multicast compression
enabled). Note:
| ExtremeSwitching X465 | 93,000 |
| ExtremeSwitching X695 | 104,000 | |
| Layer-3 IPv6 Multicast—maximum number of <S,G,V>
entries installed in the hardware (IP multicast compression
enabled). Note:
| ExtremeSwitching X465 | 48,000 |
| ExtremeSwitching X695 | 52,000 | |
| Load
sharing—maximum number of load sharing groups. Note: The actual number of load-sharing groups that can
be configured is limited by the number of physical ports present in the switch or
SummitStack.
| ExtremeSwitching, X465, X695 | 128 |
| Load sharing—maximum number of ports per load-sharing group. | For standalone: ExtremeSwitching, X465, X695 | 32 |
| For stacked: ExtremeSwitching, X465, X695 | 64 | |
| Logged messages—maximum number of messages logged locally on the system. | ExtremeSwitching, X465, X695 | 20,000 |
| MAC-based security—maximum number of MAC-based security policies. | ExtremeSwitching, X465, X695 | 1,024 |
| MAC Locking—Maximum number of MAC locking stations that can be learned on a port. | ExtremeSwitching, X465, X695 |
64 (static MAC locking stations) 600 (first arrival MAC locking stations) |
| Meters—maximum number of meters supported. | ExtremeSwitching, X465, X695 | 2,048 |
| Maximum mirroring instances. | ExtremeSwitching, X465, X695 TableOtherOnly two or four mirroring
instances will be active at a time, depending on the mirroring filter added to it. There are
four hardware resource slots. Each single instance uses one such slot, while each ingress plus
egress instance uses two slots. You can use a total of four slots, while there are no more
than two egress instances. The maximum possible combination for mirroring instances:
| 16 (including default mirroring instance) |
| Mirroring
(filters)—maximum number of mirroring filters. Note: This is the number of filters across all the active mirroring
instances.
| ExtremeSwitching, X465, X695 | 128 |
| Mirroring,
one-to-many (filters)—maximum number of one-to-many
mirroring filters. Note: This is the number of filters across all the active mirroring
instances.
| ExtremeSwitching, X465, X695 | 128 |
| Mirroring, one-to-many (monitor port)—maximum number of one-to-many monitor ports. | ExtremeSwitching, X465, X695 | 16 |
| MLAG ports—maximum number of MLAG ports allowed. Note: The number of MLAG ports that can be configured is limited by the number of physical ports
present in the system.
| ExtremeSwitching X695 | 61 |
| ExtremeSwitching X465 | 55 | |
| Stacking | 480 | |
| MLAG peers—maximum number of MLAG peers allowed. | ExtremeSwitching, X465, X695 | 2 |
| Multicast listener discovery (MLD) snooping per-VLAN filters—maximum number of VLANs supported in per-VLAN MLD snooping mode. | ExtremeSwitching X465, X695 | 1,500 |
| Multicast listener discovery (MLD)v1 subscribers—maximum number of MLDv1 subscribers per port.n | ExtremeSwitching X465, X695 | 4,000 |
| Multicast listener discovery (MLD)v1 subscribers—maximum number of MLDv1 subscribers per switch.n | ExtremeSwitching X465, X695 | 45,000 |
| Multicast listener discovery (MLD)v2 subscribers—maximum number of MLDv2 subscribers per port.n | ExtremeSwitching X465, X695 | 4,000 |
| Multicast listener discovery (MLD)v2 subscribers—maximum number of MLDv2 subscribers per switch.n | ExtremeSwitching X465, X695 | 45,000 |
| Multicast listener discovery (MLD)v2 maximum source per group—maximum number of source addresses per group. | ExtremeSwitching, X465, X695 | 200 |
| Multicast listener discovery (MLD) SSM-map entries—maximum number of MLD SSM mapping entries. | ExtremeSwitching, X465, X695 | 500 |
| Multicast listener discovery (MLD) SSM-MAP entries—maximum number of sources per group in MLD SSM mapping entries. | ExtremeSwitching, X465, X695 | 50 |
| Network Login—maximum number of clients being authenticated on MAC-based VLAN enabled ports. | ExtremeSwitching, X465, X695 | 1,024 |
| Network Login—maximum number of clients being authenticated with policy mode enabled with TCI overwrite enabled. | ExtremeSwitching, X465 | 1,024 |
| ExtremeSwitching X695 | 512 | |
| Network Login—maximum number of dynamic VLANs. | ExtremeSwitching, X465, X695 | 2,000 |
| Network Login VLAN VSAs—maximum number of VLANs a client can be authenticated on at any given time. | ExtremeSwitching, X465, X695 | 10 |
| Network Service Identifiers (NSI)/VLAN mappings—maximum number of VLANs to NSI mappings. | ExtremeSwitching, X465, X695 | 94 |
| Network Address Translation (NAT) VLANs—maximum number of NAT VLANs. | ExtremeSwitching X465, X695 | 4 |
| Network Address Translation (NAT) Sessions—number of NAT sessions supported (non twice-NAT). | ExtremeSwitching X465, X695 | 1,023 |
| Node Alias—maximum number of entries per slot. | ExtremeSwitching, X465, X695 | 8,192 |
| ONEPolicy Dynamic ACL Rules—maximum number of Dynamic ACLs supported via RADIUS VSA 232 per user in Access-List mode. | ExtremeSwitching, X465, X695 | 64 |
| ONEPolicy Roles/Profiles—maximum number of policy roles/profiles. | ExtremeSwitching, X465, X695 | 63 |
| ONEPolicy Rules per Role/Profile—maximum number of rules per role/policy. | ExtremeSwitching X465, X695 |
IPv4 Rules: 512 IPv6 Rules: 512 MAC Rules: 512 L2 Rules: 440 |
| ONEPolicy Authenticated Users per Switch—maximum number of authenticated users per switch only with TCI-Overwrite enabled. | ExtremeSwitching, X465 | 1,024 |
| ExtremeSwitching X695 | 512 | |
| Stacking | Depends on the stack nodes, but the maximum is 65,535. | |
| ONEPolicy Authenticated Users per Switch—maximum number of
authenticated users per switch with TCI-Overwrite disabled. Note: The maximum values assume 75% utilization of VLAN-XLATE hash
table.
| X465 | 24,576 |
| ExtremeSwitching X695 | 12,288 | |
| Stacking | 1,536–65,534 | |
| ONEPolicy
Authenticated Users per Port per Switch— maximum number of
authenticated users per port per switch with TCI overwrite
disabled. Note: The maximum values assume 75% utilization of VLAN-XLATE hash
table.
| ExtremeSwitching X695 | 12,288 |
| ExtremeSwitching X465 | 24,576 | |
| ONEPolicy Authenticated Users per Port per Switch— maximum number of authenticated users per port with only with TCI-Overwrite enabled. | ExtremeSwitching, X465 | 1,024 |
| ExtremeSwitching X695 | 512 | |
| ONEPolicy Permit/Deny Traffic Classification Rules Types—total maximum number of unique permit/deny traffic classification rules types (system/stack). | ExtremeSwitching X465, X695 | 1,976 |
| ONEPolicy Permit/Deny Traffic Classification Rules Types—maximum number of unique MAC permit/deny traffic classification rules types (macsource/macdest). | ExtremeSwitching X465, X695 | 512 |
| ONEPolicy Permit/Deny Traffic Classification Rules Types—maximum number of unique IPv6 permit/deny traffic classification rules types (ipv6dest). | ExtremeSwitching X465, X695 | 512 |
| ONEPolicy Permit/Deny Traffic Classification Rules Types—maximum number of unique IPv4 permit/deny traffic classification rules (typesipsource / ipdest / ipfrag / udpsourceportIP / udpdestportIP / tcpsourceportIP / tcpdestportIP / ipttl / iptos / iptype). | ExtremeSwitching X465, X695 | 512 |
| ONEPolicy Permit/Deny Traffic Classification Rules Types—maximum number of unique Layer 2 permit/deny traffic classification rules (ethertype/port). | ExtremeSwitching X465, X695 | 440 |
| OnePolicy Maximum number of rules supported in AccessList mode—maximum number of rules in AcessList mode. | ExtremeSwitching X695 | 3,512 |
| ExtremeSwitching X435 | 440 | |
| Policy-based routing (PBR) redundancy—maximum number of flow-redirects. |
ExtremeSwitching, X465, X695 | 256o |
| Policy-based routing (PBR) redundancy—maximum number of next hops per each flow-direct. |
ExtremeSwitching, X465, X695 | 32o |
| Private VLANs—maximum number of subscribers. Assumes a minimum of one port per network and subscriber VLAN. | ExtremeSwitching X695 | 71 |
| ExtremeSwitching X465 | ||
| Private VLANs—maximum number of private VLANs with an IP
address on the network VLAN. Note: This limit is dependent on the maximum number of private
VLANs in an L2-only environment if the configuration has tagged and translated ports.
| ExtremeSwitching, X465, X695 | 1,024 |
| Private VLANs—maximum number of private VLANs in an L2-only environment. | ExtremeSwitching, X465, X695 | 1,280 |
| Route policies—suggested maximum number of lines in a route policy file. | ExtremeSwitching, X465, X695 | 10,000 |
| RIP Learned Routes—maximum number of RIP routes supported without aggregation. | ExtremeSwitching X465, X695 | 10,000 |
| RIP interfaces on a single router—recommended maximum number of RIP routed interfaces on a switch. | ExtremeSwitching, X465, X695 | 256 |
| RIPng learned routes—maximum number of RIPng routes. | ExtremeSwitching, X465, X695 | 3,000 |
| Spanning Tree (maximum STPDs)—maximum number of Spanning Tree Domains on port mode EMISTP. | ExtremeSwitching X465, X695 | 64 |
| Spanning Tree PVST+—maximum number of port mode PVST
domains. Note: For all platforms, the maximum number of active ports per PVST
domain depends on the maximum number of spanning tree ports supported on given platform. For
example, on a switch that supports 256 PVST domains (maximum) and 4,096 STP ports (maximum),
the maximum number of active ports per PVST domain would be 16 ports (4,096 ÷ 256).
| ExtremeSwitching X465, X695 | 384 |
| Spanning Tree—maximum number of multiple spanning tree instances (MSTI) domains. | ExtremeSwitching, X465, X695 | 64 |
| Spanning Tree—maximum number of VLANs per MSTI. Note: Maximum number of 10 active ports per VLAN when all
500 VLANs are in one MSTI.
| ExtremeSwitching, X465, X695 | 600 |
| Spanning Tree—maximum number of VLANs on all MSTP instances. | ExtremeSwitching, X465, X695 | 1,024 |
| Spanning Tree (802.1d domains)—maximum number of 802.1d domains per port. | ExtremeSwitching, X465, X695 | 1 |
| Spanning Tree (number of ports)—maximum number of ports including all Spanning Tree domains. | ExtremeSwitching, X465, X695 | 4,096 |
| Spanning Tree (maximum VLANs)—maximum number of STP-protected VLANs (dot1d and dot1w). | ExtremeSwitching, X465, X695 | 1,024 |
| SSH (number of sessions)—maximum number of simultaneous SSH sessions. | ExtremeSwitching, X465, X695 | 8 |
| Static MAC multicast FDB entries—maximum number of permanent multicast MAC entries configured into the FDB. | ExtremeSwitching, X465, X695 | 1,024 |
| Syslog servers—maximum number of simultaneous Syslog servers that are supported. | ExtremeSwitching, X465, X695 | 16 |
| Syslog targets—maximum number of configurable Syslog targets. | ExtremeSwitching, X465, X695 | 16 |
| Telnet (number of sessions)—maximum number of simultaneous Telnet sessions. | ExtremeSwitching, X465, X695 | 8 |
| Virtual routers—maximum number of user-created virtual routers that can be created on a switch. | ExtremeSwitching, X465, X695 | 63 |
| Virtual router forwarding (VRFs)—maximum number of VRFs
that can be created on a switch. Note: * Subject to other system limitations.
| ExtremeSwitching, X465, X695 | 960 * |
| Virtual router protocols per VR—maximum number of routing protocols per VR. | ExtremeSwitching, X465, X695 | 8 |
| Virtual router protocols per switch—maximum number of VR protocols per switch. | ExtremeSwitching, X465, X695 | 64 |
| VLAN aggregation—maximum number of port-VLAN combinations on any one superVLAN and all of its subVLANs. | ExtremeSwitching, X465, X695 | 1,000 |
| VLANs—includes all VLANs. Note: Only 4,092 user-configurable VLANs are supported. (VLAN 1
is the default VLAN, and 4,095 is the management VLAN, and you may not configure them.)
| ExtremeSwitching, X465, X695 | 4,094 |
| VLANs (Layer 2)—maximum number of Layer 2 VLANs. | ExtremeSwitching X465, X695 | 4,094 |
| VLANs (Layer 3)—maximum number of VLANs performing IPv4 and/or IPv6 routing. Excludes sub-VLANs. | ExtremeSwitching X465, X695 | 2,048 |
| VLAN Port Interfaces (VPIF)—maximum number of VLAN port interfaces. | ExtremeSwitching X465, X695 | 131,585 |
| VLANs (maximum active port-based)—maximum active ports per VLAN when 4,094 VLANs are configured with the default license. | ExtremeSwitching X465, X695 | 32 |
| VLANs (maximum active protocol-sensitive filters)—number of simultaneously active protocol filters in the switch. | ExtremeSwitching, X465, X695 |
16 |
| VLAN translation—maximum number of translation VLANs. Assumes a minimum of one port per translation and member VLAN. | ExtremeSwitching X695 | 71 |
| X465 | ||
| VLAN translation—maximum number of translation VLAN pairs
with an IP address on the translation VLAN. Note: This limit is dependent on the maximum number of
translation VLAN pairs in an L2-only environment if the configuration includes tagged and
translated ports.
| ExtremeSwitching X465, X695 | 1,024 |
| VLAN translation—maximum number of translation VLAN pairs in an L2-only environment. | ExtremeSwitching, X465, X695 | 2,046 |
| VMAN CEP—maximum number of CVIDs. Note: With 75% hash
table utilization.
| ExtremeSwitching X465 | 24,000 |
| XML
requests—maximum number of XML requests per second. Note: Limits are dependent on load and type of XML request. These
values are dynamic ACL data requests.
| ExtremeSwitching, X465, X695 | 10 with 100 DACLs |
| XNV authentication—maximum number of VMs that can be processed (combination of local and network VMs). | ExtremeSwitching, X465, X695 | 2,048 |
| XNV database entries—maximum number of VM database entries (combination of local and network VMs). | ExtremeSwitching, X465, X695 | 16,000 |
| XNV database entries—maximum number of VPP database entries (combination of local and network VPPs). | ExtremeSwitching, X465, X695 | 2,048 |
| XNV dynamic VLAN—Maximum number of dynamic VLANs created (from VPPs /local VMs). | ExtremeSwitching, X465, X695 | 2,048 |
| XNV local VPPs—maximum number of XNV local VPPs. | ExtremeSwitching, X465, X695 |
2,048 ingress 512 egress |
| XNV policies/dynamic ACLs—maximum number of policies/dynamic ACLs that can be configured per VPP. | ExtremeSwitching, X465, X695 |
8 ingress 4 egress |
| XNV network VPPs—maximum number of XNV network VPPs.p | ExtremeSwitching, X465, X695 |
2,048 ingress 512 egress |