The following issues were resolved in version 34.1.1. Version 34.1.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, 32.6.x, 32.7.x, 33.2.1, 33.3.1, 33.4.1, 33.5.x, 33.6.x, and 34.1.1.
| Defect Number | Description |
|---|---|
| General | |
| CFD-14144 | The show switch management command displays image integrity checking as unknown instead of valid. |
| CFD-14863 | Broadcast and Multicast counters are not incremented in the show port mgmt stat command. |
| CFD-15771 | Need provision for "Port-Based FDB-Flush" in EAPS implementation, which can be used in scaled networks to minimize hardware programming load. |
| CFD-15797 | SNMP error occurs after upgrade to 32.7.3. |
| CFD-15926 | The restart auto-provision cloud-connector CLI need to be introduced, which will be used to by ExtremeCloud™ IQ Site Engine for license refresh. |
| CFD-16425 | A port disabled by ELRP permanently due to a loop in a dynamic VLAN is re-enabled as soon as the dynamic VLAN is deleted. |
| CFD-16501 | When one of the stack member is removed/rebooted, show fans display "operational at 0 RPM" instead of Empty |
| CFD-16672 | SFLOW sub-sampling is set to 2 eventhough all ports are configured with the same sample-rate |
| CFD-16675 | Improved log message when an Access profile denies access based on an implicit deny without a deny entry in dynamic ACL. |
| CFD-16874 | PIM join messages was not processed by the RP when it receives (S, G, RPT) after the interface pruned. |
| CFD-16898 | The MRP process crashes when simultaneously enabling MVRP on an MLAG port on both MLAG peers. |
| CFD-16939 | BGP blackhole entry remains in the kernel after removing the corresponding NLRI entry from the BGP route policy. |
| CFD-16988 | Rx Jabber is incrementing even when port is disabled. |
| CFD-17014 | On switches that don't have a dedicated OOB mgmt port, a memory leak occurs in the nettools process whenever cloud-connector is run. |
| CFD-17056 | NTP configuration was lost after reboot if DHCP is enabled on the VLAN. |
| CFD-17172 | VXLAN traffic not passing through a CEP CVID port of a VMAN. |
| CFD-17311 | cfgmgr process crash noticed during license check on Universal platforms if the switch has user-created VR in the configuration. |
| CFD-17407 | Help-text of debug hal show optic-info needs to be updated. |
| CFD-17522 | VLAN process crash due to exdb infrastructure handler. |
| CFD-17872 | The show switch non-volatile-storage health-check command is restricted for non-admin users. |
| CFD-17925 | Password for user admin is not getting updated when trying to change it using Web GUI / Chalet. |
| CFD-17994 | Timezone configuration in show configuration devmgr command output displays autodst even when it is not enabled explicitly. |
| CFD-18345 | Netlogin memory leak occurs due to authRequest. |
| CFD-18356 | Process cliMaster crashes when the restart process exsshd command is issued in an SSH session, leading to switch resets. |
| CFD-18422 | POE process crash occurs in X440-G2. |
| CFD-18464 | The OSPF process crashes when the show ospf lsdb detailcommand is executed simultaneously on multiple CLI sessions. |
| EXOS-39816 | In MLAG environment, packet blocking is not functioning correctly, resulting in duplicate packet forwarding and Layer 2 loops. |
| EXOS-39930 | In ExtremeCloud™ IQ, collection for device not complete after adding SSH access profiles in the switch. |
| X435 Series Switches | |
| CFD-17487 | When high amount rx pause frames are received on a port, the CPU bound traffic gets affected from the switch impacting the features like LACP/LAG. |
| X695 Series Switches | |
| CFD-15337 | Error log "Failed to set fec config on port 1, rv = -18" occurs after rebooting the switch. |