Wall Mounting AP-8163 using Extension Arms
To use the extension arm with the mounting hardware kit:
- With the open slot connections facing down, attach
the angle adjust bracket section at the desired mounting location using four
#10/32 lag bolts.
- Complete the steps for assembling and positioning the angle adapter bracket and
Access Point bracket sections outlined above. See Vertical Pole Mount.
- With the Access Point positioned so the gore vent is facing down, attach the
extension arm to the Access Point bracket section with two ½ inch bolts and
nuts. Tighten bolts to 300 inch pounds (lbf-in).