Resolved Issues in ExtremeXOS 16.2.2

The following issues were resolved in ExtremeXOS 16.2.2. ExtremeXOS 16.2.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, and ExtremeXOS 16.2. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 16.2.2

CR Number Description
General
xos0065519 Loops may occur in network after the performing the following specific sequence:
  1. Enable STP in any VLAN with specific set of ports.
  2. Delete all ports from that VLAN.
  3. Add same set of ports to another VLAN.
  4. Enable EAPS/ESRP/STP protocol on this new VLAN.
xos0052432 Need provision for advertising/receiving unique local IPv6 unicast address (ULA) using BGP protocol.
xos0055511

While configuring STP (802.1d) with port-encapsulation mode as EMISTP where the L2PT-enabled VMAN and access VLAN have the same tag, the designated bridge is not accepting the L2PT tunneled BPDUs from the root bridge, and thus causes a loop (designated bridge also becomes a root bridge).

This problem does not occur:

  • When the access VLAN's tag and the L2PT-enabled VMAN‘s tag are different.
  • Without any L2PT configured, with the same tag used for the access VLAN and provider-edge VMAN.
  • When using Per-VLAN Spanning Tree Plus (PVST+), regardless of same or different tags.
xos0056389 With Priavte VLAN, netlogin clients connected in isolated subscriper VLAN are not getting authenticated after disabling and enabling netloging MAC.
xos0062037 DHCP snooping entry gets programmed without client port number.
xos0062912 SNMP trap sent for link up/down status change does not include port instance.
xos0063190 Session timeout value is inappropriately overwriting the idle time-out value whenever both session timeout and idle timeout values are same, or the idle timeout value is 0.
xos0063194 Dot1x authentication fails after rebooting the client when it is connected using an IP phone.
xos0063326 Need to reduce the severity of "BGP resource full" message from Error to Info.
xos0063509 Controlling trap behavior is not working in NetLogin.
xos0063551 SNMP polling on CFM segment frame-delay statistics returns incorrect values.
xos0063837 After deleting pstag port from a VLAN that has two LAG ports added as untagged, an error message appears.
xos0063995 SNMP sysUpTime does not return correct value after failover.
xos0064023 L3 table full log appears because of false resource full triggered by link flaps.
xos0064029 Cannot delete prefixes for VLAN router advertisement messages after setting them.
xos0064094 Removing subscriber VLAN from one PVLAN affects traffic in another PVLAN.
xos0064114 SNMP process ends unexpectedly with signal 6 after running the switch for a long time.
xos0064170 When ClearFlow is enabled with around 4,000 rules with separate counters, the HAL process utilization almost always stays at 40%.
xos0064220 Calling-station-id attribute is missing in the RADIUS request for mgmt-access.
xos0064281 In Chalet, switch inappropriately displays logs for user accounts under enhanced security mode.
xos0064299 The hal process ends unexpectedly after executing the command debug packet capture on.
xos0064436 When adding ports to VLAN from Chalet, IP forwarding gets disabled for that VLAN.
xos0064459 Nettools process ends unexpectedly with signal 11 when processing router advertisement packets with DNSSL option.
xos0064491 The configuration of a disabled VLAN without any ports does not appear in the output of the show configuration command.
xos0064501 Lacking forbidden VLAN concept in OnePolicy feature.
xos0064573 ACL process ends unexpectedly after refreshing a policy with clear-flow rules.
xos0064706 Cannot use SSH client after using "vi script.py" or "load script script".
xos0064707 Error message from the load script command does not indicate that Python is a supported script language.
xos0064841 LLDP stops advertising VLAN information on port after enabling LAG.
xos0064884 "remove-private-AS-numbers" setting in BGP is not preserved after switch reboot.
xos0064889 Layer 3 traffic through an MLAG peer in a failed state is not forwarded when there is a state change in the EAPS ring where this MLAG peer is a transit node.
xos0064904 With a frequent re-authentication period set (>= 30 seconds), NetLogin process leaks memory.
xos0064956 EDP neighbors are not displayed when remote mirroring is disabled or after unconfiguring a monitor port of remote mirroring.
xos0064984 Kernel oops occurs randomly when continuous SSH connection attempts are made to the switch.
xos0065056 After applying meter to multiple VLANs, switch stops responding after executing show access-list meter vlan.
xos0065073 Kernel oops observed when IPv6 duplicate address detected in the switch.
xos0065189 BGP secondary best path is not active when primary best path goes down.
xos0065210 With account lockout feature configured, an appropriate log message is not generated when users are locked out after three unsuccessful login attempts.
xos0065218 DHCP binding restoration fails if the file name is configured with directory name.
xos0065313 Need Idle-timeout feature added to Chalet.
xos0065321 With SSH session, source address information is not sent to TACACs accounting server.
xos0065393 Memory leak occurs in HAL process after FDB entries age out.
xos0065479 A CLI option is needed to save the state of whether or not the following traps are enabled for cfgMgmtConfigChangeTrap and cfgMgmtSaveConfigTrap.
xos0065525 Need modifications in port ID TLV. Device ID TLV is sent in CDP messages.
xos0065552 RADIUS-accounting request packet shows incorrect reason for client termination.
xos0065615 Local multicast traffic is not egressing using a newly added member port in a LAG.
xos0065661 IPMC error messages occur when multicast cache entries are created/deleted for sub-VLAN, when sub-VLAN and super-VLAN belong to different virtual routers.
xos0065805 Constant flush happens in ERPS non-revertive mode when the port being blocked is non-RPL
xos0065871 LLDP process ends unexpectedly with signal 6 when doing SNMP walk for lldpXMedLocLocationTable.
xos0065897 When continuous SSH attempts are made to a switch, exsshd process ends unexpectedly with signal 6.
xos0065943 SNMP walk for extremePortUtilizationTable returns integer value, but CLI output returns decimal value.
xos0066060 OpenFlow error message appears when rule is not getting installed in hardware and same flow is received immediately for another installation.
xos0066156 Switch reboots unexpectedly due to memory leak in dot1ag process.
xos0066345 XMLC process ends unexpectedly with signal 6 when sending XML notification to Ridgeline server.
xos0061169 Need an option to use hostname while uploading log using command upload log.
xos0063158 HAL.VLAN error message occurs when enabling/disabling OpenFlow.
xos0064393 Traffic is not forwarded to VPLS peer after disabling sharing on service port when both untagged VMAN and tagged VLAN are configured on the same port.
xos0066367 Need to have a "clear" command to change ERPS ring state from "pending" to "idle" state.
xos0066398 COA disconnects are incorrectly logged as idle timeouts in EMS.
xos0054151 DHCP server configuration is lost after reboot when IP DAD is on.
xos0062722 NetLogin does not work after a port moved to translation VLAN expires.
xos0063424 Source MAC address is learned on the incorrect VLAN for double-tagged packets with inner VLAN ID that is the same as the VPLS service VLAN ID.
xos0063959 BGP routes become unfeasible when default routes are advertised through OSPF or BGP.
xos0064216 Unable to ping a destination which is reachable, if the destination is also present locally but disabled.
xos0064523 Dynamic ACL rule is not removed properly when turning off packet capture.
xos0064525 Policy does not allow regular expression to be specified for BGP communities.
xos0064874 Tagged frames should be processed for authentication with NetLogin and policy enabled.
xos0064909 Traffic loss occurs while changing and reverting the base VID of VLANs with PSTag ports.
xos0064910
The following error message appears when changing tag value in VLANs with port-specific tag configured ports:
"<Erro:Kern.MPLS.Error> MPLS bcm_esw_mpls_port_match_vlan_del failed"
xos0064960 Multicast traffic is forwarded through MVR receiver port in a VLAN even if there is no active receiver.
xos0065109 Packets with DMAC as multicast MAC and DIP as unicast IP are software forwarded when IGMP filter mode is per-VLAN.
xos0065110 Creating one VLAN starting with "vr" causes the show iproute vr vr-mgmt command to not recognize "vr-mgmt" in the syntax.
xos0065120 Configuring port display-string with special characters causes page loading issues on Chalet.
xos0065197 Rtmgr process ends unexpectedly with signal 11 after issuing restart ports all command in peer switch with BGP enabled.
xos0065215 Slow xmld process memory leak occurs when EPIC center polling the switch.
xos0065301 FDB entries are not programmed in the hardware as programmed in the software.
xos0065344 The output of the show vid command shows flag status incorrectly.
xos0065372 MPLS error messages are seen when disable/enable network vlan.
xos0065648
When a MAC address moves from a NetLogin-enabled port (mac-vlan mode) to a non-NetLogin-enabled port, the VLAN_MAC table can become full resulting in the following message:
<Warn:HAL.FDB.MacVlanAddFail> MAC-based VLAN entry 78:7E:61:A1:DC:DC vlan 2600 addition to port 22 failed, Table full
xos0065977 Random Nettools process crash observed with signal 5, when router discovery and DNS is enabled.
xos0064423 In BlackDiamond 8800 and X8 series switches, flooding to a VPLS peer does not work after adding a new port to an existing LAG group.
xos0060184 After configuring MVRP registration forbidden, the command is accepted and registration is forbidden. However, the show configuration mrp command does not display this configuration and this configuration is not retained after a reboot.
xos0061948 VLAN statistics not working after modifying the shared group.
xos0064735 VMAN CEP configuration gets removed from hardware while removing member port from LAG.
xos0065159 OpenFlow process ends unexpectedly with signal 11 when OpenFlow controller installs LLDP flow.
xos0065291 One-to-many mirroring is not working.
xos0065292 Traffic is not forwarded from member VLAN to untagged ports in translation VLAN.
xos0065322 IPv6 neighbor-discovery max_pending_entries configuration for USER-VR does not appear in output of show configuration command and is lost after reboot.
xos0055519 Error message is reported when configuring OpenFlow controller with hostname instead of IP address.
xos0062835 Upload log command times out when the memory-buffer size is >= 18000.
xos0060461 Need command option for iBGP and eBGP protocolS under the configure iproute ipv6 priority command.
xos0063960 Several help options do not appear for the show fdb command.
xos0065104 FDB is not removed from software after ageing period.
xos0065845 Traffic drops between the CVID configured ports in the VPLS service VMAN when CEP egress filtering is enabled.
xos0066140 RSTP BPDU is not transmitted even though STP state is in forwarding mode when loop-protect is enabled.
xos0064568 After slot reboot, traffic drop occurs on VPLS service VLAN LAG port.
xos0065542 Kernel crash occurs when rebooting the switch with a physical loop.
xos0065261 Traffic loss occurs in one VLAN when another VLAN with a loop causes significant congestion.
xos0061359 Policy has no PVID after unconfiguring the switch.
xos0063806 After establishing SSH session with switch for some time, SSH login fails and the command show management becomes unresponsive.
xos0065712 When repeated login and logout is performed using SSH-PKI (SSH login using certificates) for about two days from eight terminals, memory leak occurs.
xos0066004 When using the same debug password on different Telnet sessions of same switch, cliMaster process ends unexpectedly.
xos0065896 Need addition of capability flags in show cdp neighbor command output.
xos0065010 Process aaa ends unexpectedly when receiving RADIUS frame with errors.
xos0066059 CLI cursor jumping when word wrapping when using SSH session.
xos0059489 ERPS process ends unexpectedly when ERPS tries to send hello packet during reboot.
BlackDiamond 8800 Series Switches
xos0065735 BlackDiamond 8500-MSM24 modules are not supported beyond the ExtremeXOS 15.6 release, but installation of for unsupported ExtremeXOS releases is not blocked.
xos0066143 IGMP snooping per-VLAN mode causes additional slice utilization in G48Te2 modules.
xos0065776 In BlackDiamond 8800 c-series modules, VRRP gateway is not reachable after reboot.
SummitStack
xos0064859 In SummitStack, gPTP process ends unexpectedly during bootup if AVB license was enabled on any of the stack nodes.
xos0064758 In SummitStacks, when doing SNMP walk for LLDP MIB, port number does not represent the ifIndex or dot1dBasePort number.
xos0065115 In a stack with a backup, configuring a RADIUS(or RADIUS-accounting) server (primary or secondary) using a hostname causes the backup to reset when trying to resolve the hostname using DNS.
xos0065157 In SummitStacks with remote mirroring configurations, the remote-tag is not added for software-forwarded packets.
xos0066331 Layer 3 traffic is not forwarded after multiple stack failovers.
xos0064575 "Operation draining timed out" error message appears while saving the configuration in stacking switch.
xos0065088 With broadcast traffic flooded across the slots, the standby node stays in rebooting state after consecutive master failovers by cycling the power off, and then on.
xos0065308 Kernel crash occurs when unconfiguring switch with maximum ACL rules.
xos0065387 SNMP times out while when saving on an eight-node stack of Summit X440 series switches.
xos0064471 Stacking ports flapped continuously after failover in presence of bi-directional known unicast traffic.
xos0066029 In Summit X460-G2 stacks, LACP keeps flapping due to forwarding one LACP PDU to another group.
xos0065150 When LAG ports are added to VPLS, LACP flap occurs after rebooting the slots in the stack.
Summit X440 Series Switches
xos0064196 Error log message "could not clear eee stats" appears after issuing clear counters command.
Summit X460 Series Switches
xos0064005 When two Summit X460 series switches are stacked with only one alternative stack port, traffic across slots does not work if the second stack port is configured as native.
Summit X670 Series Switches
xos0064855 On Summit X670-48X switches, some ports do not become active when using 5 M SFP+ passive copper cable connected to Summit X450-G2 series switches.
Summit X460-G2 Series Switches
xos0064684 On Summit X460-G2 series switches, ESVT test does not start if the loopback port used is a 10G port.