The following issues were resolved in ExtremeXOS 16.2. ExtremeXOS 16.2 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, and ExtremeXOS 16.1.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
xos0064215 |
The following log message appears when a subnet is reachable both using MPLS and
non-MPLS:
<Warn:Kern.IPv4FIB.Warning> Slot-4: dest 0x0A420000 / 24 nexthop 0xAC11121E: Unable to add route to unit 1, rc Entry not found. Shadow problem. |
Summit X430 Series Switches | |
xos0059486 | On Summit X430 series switches, optics are not detected after repeated removal and reinsertion of optics when CPU is busy. |
xos0064084 | In Summit X430 series switches, the command show power details displays fan status as "empty". |
Summit Series Switches | |
xos0059007 | QSFP+ to SFP+ adapter support is added to work with all optical SFP+ transceivers with the exception of LRM and passive copper direct attach cables. |
xos0059484 | Gigabit Ethernet compliance value is shown as "UNKNOWN" for BXU/D optics. Also, DDMI values do not appear. Media Type appears as "NONE" in show ports configuration command. |
xos0059508 | Link does not come up when 1G BX U/D optics are inserted
into 10G SFP+ ports. Note: Configure the port for speed 1,000 with auto-negotiation “on” using the command
configure port <> auto on speed 1000
duplex full. For Summit X670V switches, remove and then re-insert the
optics. For all Summit switches, except the X670V, the corrected behavior persists
even after rebooting. For Summit X670V switches after rebooting, the transceiver
must be removed, and then re-inserted.
|
xos0062570 | In SummitStacks, executing the command enable sflow ports all enables sFlow inappropriately on stacking ports. |
xos0062821 | ACL rules installed are not mapped to single virtual group even though ACL action-resolution mode is highest-priority. |
Summit X440 Series Switches | |
xos0060466 | RX CRC errors with traffic loss occur when “CBL, SFPP, PASSIVE 10GB-C10-SFPP, 10M" from Tyco is inserted into Summit X440-48t-10G switches SFP+. |
xos0062362 | On Summit X440-24t series switches, process rtmgr pid 1572 ends unexpectedly with signal 11 error after disabling BGP with compressed routes. |
xos0062621 | On Summit 440-8p switches, the show fan command output displays that the fan is unsupported. |
xos0063627 | ARP is not re-added to hardware after it is removed initially due to the table being full. |
xos0064050 | While running diagnostics on a Summit X440 10G model switch with revision 10 and diagnostics test version 6.0 or above, "Test loopback phy fiber" and "Test snake interface" fail. |
Summit X440-G2 Series Switches | |
xos0063317 | When policy is enabled one less than the max number of netlogin users can be handled per slot. |
xos0062775 | With 32 Up MEPs configured, saving and rebooting produces the following
errors:10/03/2015 18:14:06.81 <Noti:EPM.system_stable> System is stable. Change to warm reset mode 10/03/2015 18:14:10.06 <Info:HAL.IPv4ACL.Info> Synching ACLs to Switch 10/03/2015 18:14:10.35 <Info:HAL.IPv4ACL.Info> Done synching ACLs to Switch 10/03/2015 18:15:11.73 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:33, 12, 33) - pibAclWrapInstall(1, 2, 1020, 5242950) returned "Table full". 10/03/2015 18:15:11.77 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:33, 13, 33) - pibAclWrapInstall(1, 2, 1021, 5242950) returned "Table full". 10/03/2015 18:15:13.26 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:5, 12, 33) - pibAclWrapInstall(1, 1, 1028, 5242950) returned "Table full". 10/03/2015 18:15:13.30 <Erro:HAL.FDB.Error> pibInstallCPUFilter(1:5, 13, 33) - pibAclWrapInstall(1, 1, 1029, 5242950) returned "Table full". 10/03/2015 18:15:15.47 <Info:HAL.Card.Info> Switch is operational |
Summit X450-G2 Series Switches | |
xos0060129 | On Summit X450-G2 series switches, 10/100/1000BASE-T SFP+ optics do not link to similar optics when in the SFP/SFP+ ports. They do link or partially link when connected to a regular triple speed copper port. |
Summit X460 Series Switches | |
xos0063206 | Cannot add L2 entries in hardware due to a full L2 table caused by hash collisions. |
xos0063595 | On Summit X460 series switches, the command to configure stacking ports does not show the native option. |
xos0063948 | Clearflow delta values are randomly not calculated properly. |
Summit X460-G2 Series Switches | |
xos0060018 | With a 0.5M, 40G QSFP MOLEX passive copper cable
inserted, disabling the port where the optic is inserted, rebooting, and then
enabling the port, the port stays in the ready state and doesn't come up as enabled.
Note: Remove and
re-insert the optics. The port then comes up as enabled.
|
xos0061486 | Combo ports have unsupported autonegotiation and half-duplex settings. |
xos0062855 | On the Summit X460-G2 series switches, VPLS packets are forwarded with two tags when the service VLAN ports are also members of an untagged VMAN. |
xos0062913 | On Summit X460-G2 series switches, copper combo port does not advertise its flow control capabilities to peers. |
xos0063495 | Policy authentication fails when RADIUS request queue has stale entries. |
xos0063811 | Summit X460-G2 series switches with ExtremeXOS 15.6
through 21.1, have the following limitations for SyncE input reference frequency:
|
Summit X480 Series Switches | |
xos0054290 | When a semicolon is missing from ACL matching criteria, the ACL process ends unexpectedly. |
xos0060614 | When exporting OSPF routes into BGP, and long policy name causes process dcbgp pid 1575 to end unexpectedly with signal 11. |
xos0061251 | For Summit X480, X460, X440, X430 series switches, and E4G-200 and E4G-400 cell site routers, Dot1p examination functionality does not work correctly for untagged ports when diffserv examination is enabled on those ports. |
Summit X670 Series Switches | |
xos0060656 | Link does not come up when 1G BX U/D optics are inserted
into 10G SFP+ ports. Note: Configure the port for speed 1,000 with auto-negotiation “on” using the command
configure port <> auto on speed 1000 duplex full. For Summit X670V switches,
remove and then re-insert the optics. For all Summit switches, except the X670V,
the corrected behavior persists even after rebooting. For Summit X670V switches
after rebooting, the transceiver must be removed, and then
re-inserted.
|
xos0061167 | Links become active without a connection with tri-speed Base-T SFP installed. |
xos0061559 | Enabling OpenFlow on VLANs causes double-wide ACL slice to be used even though it can fit in single-wide slice. |
xos0063052 | Traffic loss occurs on computer connected to Summit X670v-48t switches when the connected switch port is oversubscribed in 100 MB mode. |
xos0063137 | Known unicast traffic is not shared between the stacking high-gig trunk ports. |
Summit X670-G2 Series Switches | |
xos0061791 | On SummitStacks containing master and standby nodes of different switches, the standby node may go to failed state after a node reboot. |
xos0062166 | On Summit X670-G2 series switches configured with L3VPN, executing the clear iparp command causes the switch to reboot with Kernel Oops. |
xos0063204 | Traffic stops on LAG ports when frequently modifying the sharing group. |
xos0063807 | On Summit X670-G2 series switches, egress ACL rule actions do not take effect on ports 64-72. |
Summit X770 Series Switches | |
xos0053867 | Internal errors occur when looking at egress port
qosmonitor after issuing any QoS command such as: enable diffser examination port all, enable diffser replacement port all, disable diffser examine port all, or disable diffser replacement port
all:Slot-1 Stack.34 # sh port 1:93 2:73 qosmonitor Error: Internal error --> no response to stats request for port 1:93. |
SummitStack | |
xos0061799 | Precedence order between policy port rules and policy MAC-based rules is not preserved following a master/backup Failover. |
xos0062217 | In SummitStacks with eight nodes and sFlow configuration, "Hardware L3 Table full" error messages appear when the stacks have a large number of Layer 3 entries. |
xos0062700 | When upgrading from ExtremeXOS 15.7 or earlier to 16.1, image download fails if image was installed in backup node first and master node second. |
xos0062949 | HAL process ends unexpectedly in stack after executing the following commands: debug hal configure stacking pdu-trace mask 0xf, debug hal configure stacking pdu-trace capture cap_file |
xos0063344 | With MLAG and LAG configurations, when a stack node comes up after a reboot, FDB entries flooded from other slots are programmed on incorrect ports internally. |
xos0061777 | Standby nodes do not come back up to operational state after they go into failed state. |
xos0062367 | ACL process ends unexpectedly on repeated refresh of ACL policy with clear-flow action. |
xos0062522 | In SummitStack switches, standby slots go to failed state when a very large number of log messages are continuously generated in the switch. |
xos0062800 | Stack node fails because of license mismatch for 3rd-party optics. |
xos0063242 | Stacks configured as DHCP clients do not respond to pinging after failover. |
xos0063490 | CFM stays down after slot reboot on a stack. |
xos0063349 | Switch stops responding to SNMP requests if SNMP get for multiple OIDs is continuously initiated. |
BlackDiamond 8800 Series Switches | |
xos0063333 | In BlackDiamond 8800 series switches, optics information is not detected and ports remain in "Ready" state after reboot. |
xos0063510 | ACL rule to deny packets matching L4 match condition stops working if a rule with VID as match condition is appended without an L4 match condition. |
xos0057419 | On BlackDiamond 8800 series switches, C-series modules reboot after enabling dot1p replacement on ports. |
xos0061260 | When learning a large number of BGP routes, routes are learned first in route table, rather than LOCAL-RIB. No routes are learned to RIB until all routes are learned in route table. All prefixes are learned in route table, and only then are all prefixes are learned to LOCAL RIB. |
xos0062009 | In BlackDiamond 8800 series switches with XL modules, clearing FDBs when there is a loop causes the FDBs to lose synchronization across slots or switching units. |
xos0062535 | On BlackDiamond 8900-10G24Xc I/O modules, packets are dropped by ACL rules with "redirect-port-list" action. |
xos0063872 | After multiple executions of run failover with redirect-flow configuration, IPv4 ping fails. |
xos0063532 | IGMP report packets are not processed when received on VMAN CEP port. |
BlackDiamond X8 Series Switches | |
xos0060666 | After failover, traffic gets flooded on the ports of service VLAN in H-VPLS core. |
xos0061639 | Packets ingressing on VLAN-bridged interfaces (Layer 2 VLANs) are not forwarded when the destination MAC address is the same as the switch MAC address, and the switch has at least one Layer 3 interface. |
xos0061902 | BlackDiamond X8 series switches use VLAN instance as index instead of router interface (rtif) for ARP entries. |
xos0062200 | BGP is not converging when there is change in network in scaling environment. When the best path goes down, BGP RIB converges. but route table is still showing old peer as gateway. |
xos0062262 | UDP profile configurations on VLANs do not take effect in BlackDiamond X8 series switches. |
xos0062306 | Packets get reflected with same tag on port-specific, tag-enabled VLANs after failover. Issue happens only on switches having both port-specific tags and MPLS RSVP-TE configurations. |
xos0062477 | BlackDiamond X8 series switches’ management ports flap and show "Detected Tx unit hung" error messages. |
xos0062499 | Multicast packets are dropped in Layer 2 bridged VLANs. |
xos0063546 | The following error message may appear when BlackDiamond
X8 modules are rebooted after configuring port
partition:<Erro:Kern.Card.Error> Slot-2: _setSchedMode: u:p=1:006 schedMode=1 err=Invalid parameter |
xos0063928 | In BlackDiamond X8 series switches, Sysuptime in sFlow packets is invalid. |
xos0063958 | BDX8-40G12X-XL module goes into reboot cycle if any physical loop is configured or a network loop is present on the module. |
xos0064010 | The command show port buffer displays an incorrect port range for 100G I/O modules. |
General | |
xos0063554 | The following vulnerability in OpenSSL exists that impacts ExtremeXOS (CVE-2015-3197): A malicious client can negotiate SSLv2 ciphers that have been disabled on the server and complete SSLv2 handshakes even if all SSLv2 ciphers have been disabled, provided that the SSLv2 protocol was not also disabled via SSL_OP_NO_SSLv2. This issue affects OpenSSL versions 1.0.2 and 1.0.1. |
xos0061745 | Ampersand used in UPM script is replaced by "& amp" in the XSF configuration. |
xos0061841 | FDB entries are not learned again after limit learning is unconfigured, and then configured again, with PSTAG configuration in SummitStacks. |
xos0061943 | MPLS process ends unexpectedly when get-next is done with incomplete OID for mplsXCIndex. |
xos0062850 | When upgrading ExtremeXOS to 15.7 or later releases, the web HTTP access is enabled even though it is disabled in the configuration. |
xos0063028 | RADIUS configuration with shared-secret of 32 character is lost after reboot. |
xos0063248 | NTP MD5 authentication with NTP server is failing. |
xos0063257 | Saving configuration fails/times-out when VLANs added to a mirror filters are renamed. |
xos0063271 | Layer 3 packets in non-default virtual routers are slow-path forwarded after disabling MPLS in the peer switch. |
xos0062255 | CEP CVID configurations is missing after adding/deleting the port from sharing. |
xos0062720 | Unable to save configuration when ACL/CFM is configured on multiple VLANs. |
xos0057931 | After rebooting the switch multiple times, the following
error log message appears:
<Erro:cm.loadErr> Failed to load configuration: timed out (after 150 seconds) while waiting for all applications to get ready to load configuration on OPERATIONAL ( eaps is still not ready yet). |
xos0061788 | The process devmgr ends unexpectedly during snmpwalk when continuous EMS logs are sent to the switch console. |
xos0062271 | CLI memory leak occurs when executing show commands with include option through script. |
xos0064043 | Unable to use a configuration file that has been copied from an existing configuration file. |
xos0064179 | MAC movement occurs in switch acting as an STP root bridge when PVST+ BPDUs are sent by peer switch using STP blocked port. |
xos0062366 | After rebooting, DHCP binding entries are not restored using vr-default. |
xos0057231 | An FDB entry created by ARP with "i" flag set is not removed from the FDB table after a static entry for the same IP address is added with a different MAC value. |
xos0063521 | A few IBGP routes are not updated in routing table when disable bgp and enable bgp commands are executed in quick succession. |
xos0064203 | Incorrect next hop is choosen by BGP route after port flap. |
xos0062441 | The process rtMgr ends unexpectedly when IPv6 static route is deleted. |
xos0060319 | Trying to create the maximum number of Layer 3 VLANs
causes the following error messages to
appear:02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: pibVlanInstallBatchFilter(): Internal error while translating IPv6MC Ctrl Port filter id on Slot 2, unit 13. 02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: Failed to install IPV6 Link-Local MC Control Packet Filter for the port 2:24 (Conduit failure) 02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: pibVlanInstallBatchFilter(): Internal error while translating IPv6MC Ctrl Port filter id on Slot 2, unit 13. 02/20/2015 11:37:34.18 <Erro:HAL.VLAN.Error> MSM-A: Failed to install IPV6 Link-Local MC Control Packet Filter for the port 2:48 (Conduit failure) |
xos0062265 | Some legacy commands are not recognized. |
xos0062277 | The command show vlan vlan_list does not show information for dynamic VLANs nor the Default VLAN. Error appears. |
xos0062427 | EDP process ends unexpectedly when CDP packets without portId TLV are received. |
xos0058750 | Neighbor discovery packets are duplicated in L2 VLANs when IPv6 addresses are configured for other VLANs that do not have any ports. |
xos0062240 | Port that was administratively disabled becomes up after enabling rx pause. |
xos0061506 | In Summit X440-G2 and X460-G2 series switches, the combo port comes up as active even though when link peer port is down. |
xos0063255 | In Chalet, VLANs are sorted incorrectly.. |
xos0064447 | Creation of user accounts through XML does not work. |
AAA | |
xos0064307 | RADIUS accounting configuration is incorrect as shown by the command show conf aaa and is lost after upgrade. |
ACL | |
xos0062537 | HAL crash occurs when redirect-port-list action contains more than 64 ports. |
xos0062619 | SSH access-profile using policy does not work with IPv6 addresses. |
xos0063082 | Updated DSCP value is not refreshed for Dynamic ACLs. |
xos0063172 | ACL action "redirect-port-list" does not take effect when another slice has a rule to match all packets with deny action. |
xos0063240 | ACL process ends unexpectedly when switch has clear-flow ACL rule with count interval greater than snmptrap generation timer. |
xos0064054 | SNMPwalk on extremeAclStatsTable returns value with port instance instead of ifIndex. |
xos0064223 | Need to add an ACL match condition for matching next-hop addresses during the look-up cycle of a packet, so that actions can be taken based on the next-hop a packet is destined for. |
xos0064490 | After upgrading from ExtremeXOS 15.2 to later release, last installed dynamic ACL rule is given more priority than previously installed rules. |
xos0062145 | With QoS configuration, ACL process signal 11 ends unexpectedly after rebooting. |
xos0063547 | Process ACL ends unexpectedly after applying a policy file with source zone as a match condition. |
xos0064129 | Policy refresh never completes with network-zone configuration. |
AVB | |
xos0062494 | Source MAC addresses learned through MVRP packets on a blocked port (STP) cause traffic to be dropped. |
BGP | |
xos0055051 | When applying an import policy to BGP, cost configured in the policy is not applied to route tables. This issue is not resolved after multiple policy refreshes nor after multiple disabling, and then enabling BGP. |
xos0058441 | After creating a BGP peering session between link local IPv6 addresses with the scope ID specified, deleting the VLAN containing link local IPv6 address. and then issuing the command show configuration bgp, switch reboots with “Epm application wdg timer warning” error message. |
xos0061129 | In a multi-peer setup with many routes (over 150K), a few routes from the preferred peer do not become active in the BGP RIB. Disabling, and then re-enabling peer, restores all routes. |
xos0061411 | Route table installs sub-optimal BGP routes (next-hop)
to kernel, while the BGP RIB shows different paths when same routes are received
from two different peers in local-RIB Note: Disable, and then enable peer or disable, and then enable
BGP.
|
xos0061505 | After a topology change in the network, BGP routes requiring two levels of recursive lookup are programmed in hardware with incorrect next hops. |
xos0063173 | Process dcbgp ends unexpectedly with signal 11 after issuing the command show bgp neighbor. |
xos0064319 | Aggregated BGP route is not transmitted to upstream neighbor when highest prefix route is received from neighbor. |
xos0064589 | While learning BGP routes, some routes are not getting installed in route table when deleting and re-adding the static route. |
xos0062260 | BGP process ends unexpectedly when local address or password is changed for BGP neighbor, and then you immediately execute a BGP show/configuration command. |
xos0064496 | BGP route policy performs improper community delete operation. |
CFM | |
xos0063506 | Traceroute MAC address in CFM domain does not return information about destination switch. |
ClearFlow | |
xos0062629 | Clearflow rule does not work properly if there is dot(.) in the ACL counter. |
Clocking | |
xos0063370 | PTP Delay Response correction field contains high value (random value) when PTP Delay response packets are passing through combo ports. |
xos0062504 | You can set a GPTP "peer delay current interval" outside of the correct range of -3 to 17.. |
Devices | |
xos0063429 | The output of the command show fan shows the fan status as empty after a hot re-seating of the fan module. |
xos0062879 | Transceiver information shows same Rx power value for 4x10G partition ports even though some ports are in ready state. |
xos0064075 | The output of the show fan command shows fan status as "Failed" after hot re-seating a fan module. |
DHCP/BOOTP | |
xos0058668 | After rebooting DHCPv6, client remains in rebooting state. |
xos0058669 | DHCPv6 client: After changing the client identifier type, and then restarting the port, old IPv6 addresses are not released, causing the show vlan command to show multiple IPv6 addresses. |
xos0061219 | Parallel-mode-enabled DHCP offer is sent using primary IPv4 address to the client for multiple offers received from server for different IPv4 addresses. |
xos0062017 | DHCP trusted port configuration is lost after disabling, and then re-enabling LAG. |
xos0064151 | Error occurs when removing DHCP configuration from VLANs when LAG ports are added to the VLANs. |
EAPS | |
xos0063282 | ExtremeXOS CLI restricts PVLAN subscriber VLAN from being configured as an EAPS-protected VLAN. |
EDP | |
xos0062472 | Source MAC addresses learned through CDP packets received on EAPS-blocked ports cause traffic to be dropped. |
ELRP | |
xos0062460 | The show configuration command output shows incorrect ELRP configuration. |
xos0062618 | ELRP forgets the disabled port information if the port is deleted from another VLAN that also has ELRP enabled. As a result, the disabled port stays disabled unless manually enabled. |
EMS | |
xos0063736 | In Syslog, username information appears as "*****" during login/logout cases. |
ESRP | |
xos0061965 | Configuring ESRP member VLANs (VRRP-enabled) produces errors. |
FDB | |
xos0062789 | Disabling learning on LAG ports does not flush FDB entries. |
xos0063368 | In an MLAG configured switch, FDBs are not installed in hardware after reboot if there are frequent MACMoves between MLAG port and ISC. |
xos0059481 | Static FDB is programmed incorrectly in hardware after a stack failover. |
Identity Management | |
xos0061781 | Identity manager entries become stale when clients are moved from one port to another in sub-VLANs. |
IGMP | |
xos0062914 | The process mcmgr ends unexpectedly after receiving corrupted IGMPv3 join packets on MLAG ports. |
ISIS | |
xos0063423 | Memory leak occurs in ISIS process when exporting OSPF routes to ISIS. |
Layer 2 | |
xos0064682 | Enabling egress VMAN CEP filtering on a CEP port sends a tagged packet, even though it should be forwarded as untagged. |
Layer 3 | |
xos0062710 | On BlackDiamond 8800 or BlackDiamond X8 series switches, with Distributed IP ARP mode on, ECMP routes are sometimes not installed when gateways flap. |
Multicast | |
xos0063245 | With IGMP per-VLAN mode, VRRP flaps occur after adding tagged ports to VLANs. |
xos0064519 | With MVR enabled on two VLANs, IGMP report packets are looped if sent to all hosts group. |
xos0062705 | Kernel oops can occur after clearing IPMC FDB in a stack. |
xos0064357 | Out of sync between PIM and RTMgr process after introducing new best route. |
LACP/LAG | |
xos0062428 | Member ports with a modified speed configuration that is different than the master port should not be allowed in LAG. |
xos0063134 | Traffic stops after disabling, and then enabling LAG porst having pstag with static FDB. |
xos0064326 | LACP flaps when the LAG ports are added to VMANAs, with the VMAN ether type same as LACP ether type. |
MLAG | |
xos0064009 | MLAG+EAPS:Traffic forwarding stops after EAPS that include ISC link converges. |
xos0064067 | Traffic loss occurs in MLAG setup when ingress port and ISC port reside on different hardware units, and when the internal port number for both of these ports is the same. |
xos0056368 | Kernel errors occur after disabling sharing configuration on ISC ports of MLAG. For example: "exvlan: handleVsmKernelRequest:8545: handleVsmKernelRequest Invalid Ingress port: 1000008 got" |
NetLogin | |
xos0061433 | extremeNetloginUserLogoutTrap is received with errors. |
xos0061868 | With protocol order as MAC dot1x, web-based UPM profile is not executed for the client, which is authenticated as MAC. |
xos0062674 | UPM profile fails to set the variables received from the RADIUS server using VSA 212. |
xos0063090 | NetLogin client does not move into authfail VLAN when user is absent from local database. |
Optics | |
xos0063120 | Error message "CFP2 modules >= 18 W unsupported" incorrectly appears for Finisar Corp CFP2 LR4 optics. |
OSPF | |
xos0061855 | Configured OSPF neighbor is not retained after rebooting. |
Policy | |
xos0062965 | Policy process ends unexpectedly with signal 6 when master node goes down. |
QoS | |
xos0062050 | QoS committed rate configurations for port groups are not loaded properly after a save and reboot. |
xos0061027 | For SummitStacks, creating or deleting non-default QoS profiles may cause some ports to flap. |
RSVP-TE | |
xos0062380 | Switch rejects incorrect LSP configurations as expected, but this operation still uses LSP indexes in hardware. |
Sflow/Netflow | |
xos0063418 | No mapping for Modid errors occur when sFlow is enabled on the port. |
SNMP | |
xos0057269 | SNMP trap extremeIpSecurityViolation is sent with incorrect VLAN description. |
xos0061507 | SNMPget on EXTREME-SOFTWARE-MONITOR table returns value with incorrect OID. |
xos0057212 | SNMP traps not sent after changing or saving configuration, even though respective traps are enabled. |
xos0063332 | Configuration changes to VPLS are not fully retrieved by SNMP walk, which returns values for only few VPLS index. |
SSH | |
xos0059942 | SSH connection ends when show commands produce lengthy output. |
STP | |
xos0057785 | STP domain tag is removed when all ports are deleted from STP auto-bind enabled-VLANs. |
xos0062133 | STP flush event does not happen after ports are quickly disabled, and then enabled. |
xos0062290 | Due to ExtremeXOS reflection RSTP BPDU support, upstream bridges believe that they are receiving their own BPDUs (contain the bridge's ID), thus causing multisource events during topology changes, which can cause slow convergence times when lp is configured (upwards of 30 seconds). |
xos0063457 | Configuration for adding network VLAN port in STP for subscriber is not saved. |
xos0063484 | Enhancement added in STP flush generation mechanism to reduce hardware programming load. |
xos0064395 | STP digest value gets changed when adding the port in VLAN or removing the port from VLAN. |
xos0062701 | HAL timeout occurs while rebooting a stack with STP configuration. |
VLANs | |
xos0063331 | VLAN IP address is unconfigured when modifying the VLAN name/port information from Chalet. |
xos0063186 | Kernel oops occurs when deleting private VLAN. |
VMANs | |
xos0063274 | VLAN packets are egressing with VMAN ethertype when an egress port is deleted from a VMAN that is also part of a VLAN. |
xos0063207 | Error occurs while adding LAG ports as tagged in one VMAN and untagged in another VMAN, even though the VMAN EtherType is primary. |
VPLS/HVPLS | |
xos0064033 | In BlackDiamond X8 and Summit X670 series switches, traffic gets software forwarded after disabling/enabling members of a shared group and recreating the shared group after deletion. |
xos0059596 | Can add more than one LSP a pseudo-wire when it is associated with a VPWS. |
xos0061092 | Traffic forwarding on VPLS-serviced VMAN stops after link flap. |
xos0062045 | LLDP packets are tunnelled over L2VPn. |
xos0062754 | VPLS traffic egresses out with dot1q tag when secondary EtherType is configured. |
xos0063842 | Packets are being flooded in both network and access VLAN ports after port flap. |
VR/VRF/L3VPN | |
xos0062128 | L3VPN traffic is not forwarded after executing disable port and enable port in MPLS core network. |
xos0052723 | With L3VPN configured (also: OSPF, BGP, MPLS, LSP) and routes are being advertised and installed in the VRF routing table, after restarting process OSPF, VPN routes are not installed. |
xos0061198 | Disabling VPN-VRF affects traffic on another VPN-VRF. |