Resolved Issues in ExtremeXOS 16.2.5-Patch1-5

The following issues were resolved in ExtremeXOS 16.2.5-Patch1-5. ExtremeXOS 16.2.5-Patch1-5 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, ExtremeXOS 16.2.3, ExtremeXOS 16.2.4, and ExtremeXOS 16.2.5. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 16.2.5-Patch1-5

CR Number Description
General  
xos0063567 OSPF stops exporting static routes when NSSA area export is disabled.
xos0070488 Chalet needs to support configuring the higher port speeds: 100G, 50G, and 25G.
xos0071788 The output of the show configuration/show configuration detail commands does not show management port related traps configuration.
xos0072564 Chalet stops responding if the port display string contains German special characters.
xos0072697 MPLS process ends unexpectedly when permanent licenses are enabled after trial license expiry.
xos0072748 After rebooting the switch, OSPF address range conflict error messages appear when summarized route range subnets between the OSPF areas overlap.
xos0072916 Traffic is not forwarded to VPLS peer after LSP path failover.
xos0072941 Memory leak occurs in policy process when ports go down.
xos0072943 PTPV2 process ends unexpectedly with signal 5 when rebooting the switch with Network Timing license enabled.
xos0072870 On SummitStacks, slots are very slow to become operational if learning is disabled on multiple VLANs.
xos0071418 Ports configured for BPDU restriction are re-enabled on recovery-timeout even if administratively disabled.
xos0060606 Dot1x authentication fails when Dot1x state machine remains in connecting state for the client.
xos0072978 Dot1x authentication fails when Dot1x state machine remains in abprtomg state for the client.
xos0073002 Need "smart refresh" support for IPv6 policies.
ExtremeSwitching X690 and X870 Series Switches
xos0072783 VLAN process ends unexpectedly when disabling all remote VXLAN tunnel end points using the command disable virtual-network remote-endpoint vxlan all.
Summit X460-G2 Series Switches
xos0072170 Traffic drops when egress CEP filtering is enabled on a VPLS service VMAN sharing port.