The following issues were resolved in ExtremeXOS 21.1.1-Patch1-5. ExtremeXOS 21.1.1-Patch1-5 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3 and ExtremeXOS 21.1.1. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0055541 | TACACS: On configuring shared secret key in encrypted form with characters "&" and "<" , the show configuration aaa output shows a different secret key from what was actually configured. |
xos0057931 | After rebooting the switch multiple times, following
error log message appears:
<Erro:cm.loadErr> Failed to load configuration: timed out (after 150 seconds) while waiting for all applications to get ready to load configuration on OPERATIONAL ( eaps is still not ready yet). |
xos0062265 | Some legacy commands are not recognized. |
xos0062444 | Kernel panic occurs in DoS protect-enabled switches when TCN SYN packets to port 80 are flooded to Management port. |
xos0063331 | VLAN IP address is unconfigured when modifying the VLAN name/port information from Chalet. |
xos0063332 | Configuration changes to VPLS are not fully retrieved by SNMP walk, which returns values for only few VPLS index. |
xos0063842 | Packets are being flooded in both network and access VLAN ports after port flap. |
xos0063995 | SNMP sysUpTime does not return correct value after failover. |
xos0064009 | MLAG+EAPS:Traffic forwarding stops after EAPS that include ISC link converges. |
xos0064054 | SNMPwalk on extremeAclStatsTable returns value with port instance instead of ifIndex. |
xos0064055 | Resiliency Enhancement for IPv4 and IPv6 Static Routes feature has been added. |
xos0064063 | Packet-Resolution match conditions need to be added as ACL match conditions. |
xos0064075 | The output of the show fan command shows fan status as "Failed" after hot re-seating a fan module. |
xos0064129 | Policy refresh never completes with network-zone configuration. |
xos0064151 | Error occurs when removing DHCP configuration from VLANs when LAG ports are added to the VLANs. |
xos0064178 | Hardware entries not released on disabling of ports in a LAG connecting an L2VPN router to the MPLS core when L2VPN sharing is configured and in use. |
xos0064179 | MAC movement occurs in switch acting as an STP root bridge when PVST+ BPDUs are sent by peer switch using STP blocked port. |
xos0064203 | Incorrect next hop is chosen by BGP route after port flap. |
xos0064215 | The following log message appears when a subnet is reachable both using MPLS
and non-MPLS:
<Warn:Kern.IPv4FIB.Warning> Slot-4: dest 0x0A420000 / 24 nexthop 0xAC11121E: Unable to add route to unit 1, rc Entry not found. Shadow problem. |
xos0064223 | Need to add an ACL match condition for matching next-hop addresses during the look-up cycle of a packet, so that actions can be taken based on the next-hop a packet is destined for. |
xos0064278 | In a SummitStack or BlackDiamond chassis, FDB is not programmed in hardware after three failovers and fallback. |
xos0064281 | In Chalet, switch inappropriately displays logs for user accounts under enhanced security mode. |
xos0064299 | The hal process ends unexpectedly after executing the command debug packet capture on. |
xos0064307 | RADIUS accounting configuration is incorrect as shown by the command show conf aaa and is lost after upgrade. |
xos0064319 | Aggregated BGP route is not transmitted to upstream neighbor when highest prefix route is received from neighbor. |
xos0064326 | LACP flaps when the LAG port is added to VMAN, with the VMAN ethertype same as LACP ethertype. |
xos0064357 | Out of sync between PIM and RTMgr process after introducing new best route. |
xos0064383 | In the show l2vpn detail command output, the "PW Tx Pkts" counters are not updated for VPWS sessions even though traffic is passing correctly. |
xos0064395 | STP digest value gets changed when adding the port in VLAN or removing the port from VLAN. |
xos0064490 | After upgrading from ExtremeXOS 15.2 to later release, last installed dynamic ACL rule is given more priority than previously installed rules. |
xos0064519 | With MVR enabled on two VLANs, IGMP report packets are looped if sent to all hosts group. |
xos0064589 | While learning BGP routes, some routes are not getting installed in route table when deleting and re-adding the static route. |
xos0064033 | In Summit X670 series switches, traffic gets software forwarded after disabling/enabling members of a shared group and recreating the shared group after deletion. |
xos0062720 | Unable to save configuration when ACL/CFM is configured on multiple VLANs. |
xos0063429 | The output of the command show fan shows the fan status as empty after a hot re-seating of the fan module. |
xos0064400 | When switch boots up with factory default configuration, Zero Touch Provisioning (ZTP+) is enabled automatically and IP is resolved correctly using DHCP, but this causes flooding to be disabled on all ports. |
xos0063693 | With L2VPN sharing, traffic loss occurs after LSP failover. |
xos0061018 | After failover, traffic fails across VPLS configured with 64 LSPs across LAG. |
xos0064312 | With VXLAN, if tenant VLAN and tunnel are on different VRs, FDB is not learned on a tunnel. |
xos0063844 | With VXLAN, MLAG port in backup slot is not added to aggregator after reboot of switch followed by disable and enable of port. |
xos0064136 | Unable to configure flood rate limit as 1 packets per second. |
Summit X670 Series Switches | |
xos0057671 | Link status goes to Ready state on port with 10/100/1000BASE-T optics after multiple reboots. |
xos0063263 | On Summit X670 series switches, 1000BaseSX optics are incorrectly detected as 100BaseFX. |
SummitStack | |
xos0061834 | In SummitStacks, the command synchronize stacking slot <slot no> does not work from master node if the target slot is in failed state. |
xos0061861 | A per-port meter configured on a SummitStack may not be properly configured on the backup node following a reboot. |
xos0062484 | EPM process crashes on master if image upgrade on a standby slot exceeds 30 minutes. |
Summit X670-G2 Series Switches | |
xos0064574 | In X670G2, IPMC cache entries are limited to 5000, when the lookup key is changed from Source-Group-Vlan to Group-Vlan mode or vice versa. |
BlackDiamond X8 Series Switches | |
xos0064010 | The command show port buffer displays an incorrect port range for 100G I/O modules. |
xos0060666 | After failover, traffic gets flooded on the ports of service VLAN in H-VPLS core. |
Summit X440 Series Switches | |
xos0063627 | ARP is not re-added to hardware after it is removed initially due to the table being full. |