Resolved Issues in ExtremeXOS 21.1.4

The following issues were resolved in ExtremeXOS 21.1.4. ExtremeXOS 21.1.4 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, ExtremeXOS 21.1.2, and ExtremeXOS 21.1.3. For information about those fixes, see the release notes for the specific release.

Click to expand in new window

Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 21.1.4

CR Number Description
General
xos0054568 ESVT fails to function with jumbo-sized loopback frames. The show esvt traffic-test output indicates the test completed successfully, but no frame counts are indicated.
xos0064727
On DHCPv6 clients, sometimes the IPv6 address is not removed even after disabling the client, and after rebooting, the IPv6 address is saved and this causes the client to go into a stopped state with the following error message appearing:
 <Erro:vlan.AddIPAddrFail> Failed to add IP addr 8001::4aa6:dd38:9b32:e7b/128 from DHCPv6 to VLAN client, DHCPv6 configured IPv6 address already exist on interface client 
xos0064741 After reboot, dirty bit is set without a configuration change if mgmt VLAN has IP address configured/obtained.
xos0064798 Configured port's STP properties are lost when the port is moved from one VLAN to another.
xos0065400 VLAN name and tag do not appear correctly when VLAN is created with VLAN name as "tag".
xos0066782 BFD session ends when removing CVID from a service VMAN port.
xos0066783 Using IDMgr, UPM, and Policy combination makes client not reachable untill IDMgr settles down.
xos0067063 Rtlookup is not able to display all the ECMP routes.
xos0067161 LACP flap occurs when disabling the mirror on port where LAG is configured with LACP.
xos0067182 Authentication on switch using RSA keys stops working if one of the user keys is deleted.
xos0067227 IDMgr entries are not flushed when ARP fast-convergence is on.
xos0067546 EPM process ends unexpectedly when SSH process is restarted while SNMP query on memory statistics is still in progress.
xos0067704 The process exsh ends unexpectedly after issuing command with include option that uses # via SSH script.
xos0067739 UDP configuration is lost after reboot with IP DAD enabled.
xos0067822 Memory leak occurs in XMLD process whenever Chalet session refresh happens.
xos0067824 STP BPDUs are continuously sent after enabling and disabling MSTP on an STP port.
xos0067841 Packets are dropped at ingress port for traffic at rate greater than 1000 pps when 500 ACL installed
xos0068191 Nettools process ends unexpectedly with signal 11 while rebooting the switch with 100+ DHCP clients connected via Relay and with Smart Relay enabled.
xos0068215 Logout dialog box appears even after disabling Netlogin logout-privilege.
xos0068302 With both HTTP and HTTPS enabled, sending HTTP request from NetLogin client causes the switch to return with HTTP response instead of HTTPS.
xos0068323 In ExtremeXOS Python scripting, the argument sent to the command Exsh.clicmd is replicated 24 times.
xos0068356 Informational messages appear on the console when an NTP-enabled VLAN becomes inactive.
xos0068556 SSH with command argument as "show commands" is not working with user account.
xos0068698 In NetLogin web, after you click the logout button, you are not redirected to a page with the message “You have logged out”.
xos0068750 AAA process ends unexpectedly with signal 11 when processing a corrupted RADIUS-challenge packet.
xos0068752 Kernel crash occurs when processing a packet with an invalid IP header length.
xos0065167 Add optic support for MGBIC-LC04 Avago HFBR-57E0PZ-EN1.
xos0067807 On BlackDiamond 8800 series switches, the VRRP process monopolizes 40–50% CPU after disable/enable slot, or after <i>restart ports all</i> when the switch has VRRP enabled on 120 STP-protected VLANs.
xos0064680 STP port-specific configuration is lost after disabling load sharing or moving the port to a different VLAN.
xos0066366 On VPLS network with LAG on access side, clearing FDB on LSRs and LERs results in traffic drop.
xos0066483 The encrypted shared secret for TACAS accounting secondary servers does not appear in the configuration.
xos0067206 Unable to login to Chalet with any account that uses an ampersand (&) character.
xos0068023 Hash collision warning message appears with invalid VRID when exceeding L3 hash table limit.
xos0067271 FDB mismatch occurs between software and hardware after deleting, and then adding, ISC port multiple times.
xos0066726 Hal process ends unexpectedly with signal 11 when trying to add port to network vlan of pvlan.
xos0067493 PTPv1 packets are dropped on the port if GPTP is enabled on the same port.
xos0066962 Port does not links up properly with GBIC Source Photonics 100FX SPGFEFXCDFCCEX.
xos0064790 Number of used "L4 Port Ranges" count is incorrect in show access-list usage acl-range port output after unconfiguring few ACL rules with "L4 port range" match condition.
xos0068374 With OSPFv3 16-way ECMP, rtlookup for destination shows multiple duplicate entries.
xos0068454 In ISP mode, if no ports are associated with the NetLogin VLAN, then the client cannot access the base URL.
xos0068057 HAL process ends unexpectedly with signal 6 and 11 when deleting and re-adding subscriber VLAN from private VLAN.
xos0067459 HAL ends unexpectedly with signal 11 while sending L3 known traffic over PVLAN configuration.
xos0068528 Link issue with 5 meter DAC cable.
xos0065009

The following error message appears when executing show tech all command from multiple Telnet sessions:

<Crit:DM.InitIPMLSrvrFail> Initialization of the IPML TCP connection for the Fault Tolerant service the on port 7750 failed.
xos0065975 Process expy ends unexpectedly with signal 11 when rebooting the switch after configuring port partition.
xos0067515 VPWS traffic forwarding stops after performing failover in the switch.
Summit X440-G2 Series Switches
xos0068466 "Fan Failures RPM out of Range" messages appear on ExtremeSwitching X440-G2 series switches.