The following issues were resolved in ExtremeXOS 21.1.4. ExtremeXOS 21.1.4 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5.2-Patch1-3, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5.4-Patch1-9, ExtremeXOS 15.2.4.5-Patch1-5, ExtremeXOS 15.3.1.4-patch1-47, ExtremeXOS 15.3.5.2-patch1-10, ExtremeXOS 15.4.2.8, ExtremeXOS 15.5.5.2, ExtremeXOS 15.6.5, ExtremeXOS 15.7.3, ExtremeXOS 16.1.3, ExtremeXOS 21.1.1, ExtremeXOS 21.1.2, and ExtremeXOS 21.1.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0054568 | ESVT fails to function with jumbo-sized loopback frames. The show esvt traffic-test output indicates the test completed successfully, but no frame counts are indicated. |
xos0064727 |
On DHCPv6 clients, sometimes the IPv6 address is not removed even after disabling
the client, and after rebooting, the IPv6 address is saved and this causes the
client to go into a stopped state with the following error message
appearing:
<Erro:vlan.AddIPAddrFail> Failed to add IP addr 8001::4aa6:dd38:9b32:e7b/128 from DHCPv6 to VLAN client, DHCPv6 configured IPv6 address already exist on interface client |
xos0064741 | After reboot, dirty bit is set without a configuration change if mgmt VLAN has IP address configured/obtained. |
xos0064798 | Configured port's STP properties are lost when the port is moved from one VLAN to another. |
xos0065400 | VLAN name and tag do not appear correctly when VLAN is created with VLAN name as "tag". |
xos0066782 | BFD session ends when removing CVID from a service VMAN port. |
xos0066783 | Using IDMgr, UPM, and Policy combination makes client not reachable untill IDMgr settles down. |
xos0067063 | Rtlookup is not able to display all the ECMP routes. |
xos0067161 | LACP flap occurs when disabling the mirror on port where LAG is configured with LACP. |
xos0067182 | Authentication on switch using RSA keys stops working if one of the user keys is deleted. |
xos0067227 | IDMgr entries are not flushed when ARP fast-convergence is on. |
xos0067546 | EPM process ends unexpectedly when SSH process is restarted while SNMP query on memory statistics is still in progress. |
xos0067704 | The process exsh ends unexpectedly after issuing command with include option that uses # via SSH script. |
xos0067739 | UDP configuration is lost after reboot with IP DAD enabled. |
xos0067822 | Memory leak occurs in XMLD process whenever Chalet session refresh happens. |
xos0067824 | STP BPDUs are continuously sent after enabling and disabling MSTP on an STP port. |
xos0067841 | Packets are dropped at ingress port for traffic at rate greater than 1000 pps when 500 ACL installed |
xos0068191 | Nettools process ends unexpectedly with signal 11 while rebooting the switch with 100+ DHCP clients connected via Relay and with Smart Relay enabled. |
xos0068215 | Logout dialog box appears even after disabling Netlogin logout-privilege. |
xos0068302 | With both HTTP and HTTPS enabled, sending HTTP request from NetLogin client causes the switch to return with HTTP response instead of HTTPS. |
xos0068323 | In ExtremeXOS Python scripting, the argument sent to the command Exsh.clicmd is replicated 24 times. |
xos0068356 | Informational messages appear on the console when an NTP-enabled VLAN becomes inactive. |
xos0068556 | SSH with command argument as "show commands" is not working with user account. |
xos0068698 | In NetLogin web, after you click the logout button, you are not redirected to a page with the message “You have logged outâ€. |
xos0068750 | AAA process ends unexpectedly with signal 11 when processing a corrupted RADIUS-challenge packet. |
xos0068752 | Kernel crash occurs when processing a packet with an invalid IP header length. |
xos0065167 | Add optic support for MGBIC-LC04 Avago HFBR-57E0PZ-EN1. |
xos0067807 | On BlackDiamond 8800 series switches, the VRRP process monopolizes 40–50% CPU after disable/enable slot, or after <i>restart ports all</i> when the switch has VRRP enabled on 120 STP-protected VLANs. |
xos0064680 | STP port-specific configuration is lost after disabling load sharing or moving the port to a different VLAN. |
xos0066366 | On VPLS network with LAG on access side, clearing FDB on LSRs and LERs results in traffic drop. |
xos0066483 | The encrypted shared secret for TACAS accounting secondary servers does not appear in the configuration. |
xos0067206 | Unable to login to Chalet with any account that uses an ampersand (&) character. |
xos0068023 | Hash collision warning message appears with invalid VRID when exceeding L3 hash table limit. |
xos0067271 | FDB mismatch occurs between software and hardware after deleting, and then adding, ISC port multiple times. |
xos0066726 | Hal process ends unexpectedly with signal 11 when trying to add port to network vlan of pvlan. |
xos0067493 | PTPv1 packets are dropped on the port if GPTP is enabled on the same port. |
xos0066962 | Port does not links up properly with GBIC Source Photonics 100FX SPGFEFXCDFCCEX. |
xos0064790 | Number of used "L4 Port Ranges" count is incorrect in show access-list usage acl-range port output after unconfiguring few ACL rules with "L4 port range" match condition. |
xos0068374 | With OSPFv3 16-way ECMP, rtlookup for destination shows multiple duplicate entries. |
xos0068454 | In ISP mode, if no ports are associated with the NetLogin VLAN, then the client cannot access the base URL. |
xos0068057 | HAL process ends unexpectedly with signal 6 and 11 when deleting and re-adding subscriber VLAN from private VLAN. |
xos0067459 | HAL ends unexpectedly with signal 11 while sending L3 known traffic over PVLAN configuration. |
xos0068528 | Link issue with 5 meter DAC cable. |
xos0065009 |
The following error message appears when executing show tech all command from multiple Telnet sessions: <Crit:DM.InitIPMLSrvrFail> Initialization of the IPML TCP connection for the Fault Tolerant service the on port 7750 failed. |
xos0065975 | Process expy ends unexpectedly with signal 11 when rebooting the switch after configuring port partition. |
xos0067515 | VPWS traffic forwarding stops after performing failover in the switch. |
Summit X440-G2 Series Switches | |
xos0068466 | "Fan Failures RPM out of Range" messages appear on ExtremeSwitching X440-G2 series switches. |