Provide ONEPolicy VLAN to Universal Port Management (UPM)

Previously, Universal Port Management (UPM) scripting (and associated SNMP traps for authentication/unauthentication) did not receive the authentication VLAN that was chosen by Policy to authenticate to. ExtremeXOS 30.4 provides this VLAN information from Policy to Network Login, so that UPM scripts can make use of this information. VLAN information also appears in the ClientAuthenticated Syslog messages.

Supported Platforms

Summit X450-G2, X460-G2, X670-G2, and ExtremeSwitching X440-G2, X465, X590, X620, X690, X870 series switches.

Limitations

Dynamic VLANS are not fully supported for this feature, since a dynamic VLAN can be created prior to the client being authenticated. In such cases, the VLAN appears as "<not found> xxx" where "xxx" is the VLAN number, rather than the VLAN name, which usually appears. UPM VLAN processing also does not function, since the VLAN has not yet been created.