The following issues were resolved in ExtremeXOS 30.4. ExtremeXOS 30.4 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, and ExtremeXOS 30.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0075849 | The command show ssl is not returning the output in a string when called by exes.api.exec_cli(); instead, the output is sent to the terminal. |
xos0075946 | On ExtremeSwitching X440G2-24x switches, Source Photonics 100FX optics link up as 1G, instead of 100 Mbps. |
xos0076030 | EDP does not work on a port when the port is an untagged member of a non-Default VLAN with tag 1. |
xos0076042 | The command show iproute origin static shows only eight entries after reboot. |
xos0076122 | After a reboot, VRRP dual master occurs for around 10–15 minutes when MLAG reload delay is enabled. |
xos0076150 | Memory depletion occurs in process aaa when executing Soap/XML commands. |
xos0076151 | ExtremeRtStats OID is not working as expected. |
xos0076184 | The command show port X transceiver information detail does not show ddmi parameters for AFBR-57E6APZ-EX1 and the "-EN1" (Extreme Branded) SFPs. The command debug hal show optic ee port X does not show the ddmi page of the eeprom. |
xos0076221 | On an unconfigured switch running ExtremeXOS 30.3, there is an issue with ZTP+ connecting to Extreme Management Center (XMC) on the management port (Mgmt VR). |
xos0076285 | In ExtremeXOS 22.5+ versions, ExtremeXOS switches are not accessible through the URI/xmlService. |
xos0076290 | Blackhole route not removed from kernel when it goes down in software level, leading to L3 connectivity issues. |
xos0075942 | After disabling, and then enabling, learning with policy, FDB is not learned. |
ExtremeSwitching X690 Series Switches | |
xos0076244 | On ExtremeSwitching X690 series switches, LACP custom sharing is not working between PE to CE. |
xos0069669 | ExtremeSwitching X690 stacks crash frequently when AoC QSFP28 cable is present in the stack. |
BGP Auto-peering | |
xos0074505 | Occasionally, while running BGP Auto-peering, enabling MLAG on a port fails. MLAG should be created before BGP Auto-peering. |
BFD | |
xos0076480 | The transmission interval of BFD control packets is changed when the BFD session is not up. |
Chalet | |
xos0076219 | In Chalet, inventory details do not appear for ONIE switches. |
ELRP | |
xos0076658 | Multicast packets dropped on SLLP guard-enabled port creates dual VRRP master. |
xos0075443 | The hardware-assisted ELRP fails to detect loops if configured VLAN ports are move to tagged from untagged. |
Fabric Attach | |
xos0076153 | Fabric Attach (FA) uplink port is removed from FA Mgmt VLAN after ZTP+ configuration is pushed. |
xos0075220 | Output of show fabric attach ports port_list authentication command, shows data for all ports, rather than just specified port. |
MLAG | |
xos0076134 | MLAG ports do not come up after reboot when reload delay is configured. |
xos0076152 | Traffic received on ISC are not blocked and sent by the MLAG port that belongs to the same MLAG ID. |
xos0076488 | When MLAG convergence control is set to fast, packet drops occur on slowpath during failover. |
MPLS | |
xos0076359 | With MPLS next-hop enabled, BGP control packets do not set Dot1p values. When MPLS exp examination/replacement is enabled, the packets do not have the proper exp bits set. |
Network Login | |
xos0076201 | On Summit X450-G2 series switches 7-node stack, Dot1x is not working after re-configuring stacking slots. |
Policy | |
xos0075723 | After re-authenticating the Dot1x client, FDB is learned on the wrong VLAN at random times. |
xos0076662 | Port not added as tagged based on egress VLAN list in policy profile after the client authentication. |
xos0074235 | Netlogin does not have access to the Authenticated VLAN of a policy-enabled session. |
SSH | |
xos0076686 | For ExtremeXOS 16.2 and later, SSH has a 3–5 seconds delay for prompt password window to appear. |
SNMP | |
xos0076049 | For QSFP+/QSFP28 optics, Rx/Tx power values do not appear correctly when fetched using SNMP. |
Stacking | |
xos0076203 | PVLAN feature does not work properly after a failover. |
xos0076215 | After multiple failovers, the Multiport FDB feature does not work as expected. |
STP | |
xos0075874 | STP convergence time increases after ISC and cascade port come up or after controlling bridge (CB) reboots causing ping traffic loss. |
VLAN | |
xos0074944 | ExtremeXOS restricts the port addition requests on VLANs to 20 million times. |
VRRP | |
xos0074578 | When configuring VRRP group on MLAGs, process vrrp pid 813 ends unexpectedly with signal 11. |
VXLAN | |
xos0075717 | In VXLAN configuration, mismatch between software and hardware FDB occurs after underlay network flaps. |