Resolved Issues in ExtremeXOS 30.7

The following issues were resolved in ExtremeXOS 30.7. ExtremeXOS 30.7 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, and ExtremeXOS 30.6. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.7
Defect Number Description
General
EXOS-20534 Extreme Management Center does not pass DNS search suffixes to ExtremeXOS switches.
EXOS-20493 Configuring Simple Loop Protection Protocol (SLPP) guard recovery timeout value as zero using :Extreme Management Center does not set a zero value for timeout on a switch, but rather is ignored and leaves the default value of 60 seconds in place.
EXOS-20230 Combining MLAG and VLAN translation, reachability issues occur.
EXOS-20132 IPv4 adjacency shows resolved when there is network loop and IP forwarding is disabled.
EXOS-20120 Node Alias configuration is not removed after running the command unconfigure slot slot no.
EXOS-19972 Image installation takes a little longer for ExtremeXOS 30.6, and the following log message might appear as a result: <Warn:EPM.Upgrade.State> Upgrade status Installation time may be greater than expected due to a lack of memory resources.
EXOS-19682 Commands implemented internally using Python script cause memory leaks.
EXOS-19308 On SummitStack, when ports are in software learning mode, FDB is not programmed in hardware on all slots resulting in flooding.
EXOS-19163 With group table is full and when flapping the port, L3 IPMC index resource leak occurs.
EXOS-20608 After unconfiguring PVLAN loop-back, PVLAN port goes down if it contains SX SFP optics and its auto-negotiation is disabled.
EXOS-20520 If the Management VLAN is created using the Fabric Attach server and DHCP packets are relayed through the fabric to the DHCP server, auto provision (ZTP) does not finish.
EXOS-26329 ExtremeXOS should process only supported TLVs and ignore unsupported TLVs in AVB signaling/announce messages.
EXOS-26446 Switch receives IGMPv1 queries from ExtremeXOS IGMP querier configured as IGMPv2.
EXOS-26217 LLDP process crash occurs when IPv6 address is encoded in a TLV.
EXOS-24246 Deprecated ip-option related CLI commands should not appear under show configuration rtmgr detail.
EXOS-26429 If MVR is enabled globally on the user virutal-router (VR), but not on the VRF, the process "mcmgr" ends unexpectedly when receiving IGMP report packets.
EXOS-24095 When snmpwalk is done for entity_mib (1.3.6.1.2.1.47.1.1.1.1) and if a QSFP-to-SFP adapter is present in the switch, process devmgr ends unexpectedly.
EXOS-24093 MIB object "IfName" is not sent in Link up/Link down SNMP traps.
EXOS-24084 After an IGMP receiver flaps twice, multicast streams are not forwarded to receivers by PIM-SSM.
EXOS-20516 Convergence takes 6 seconds when port down/up coincides with optics polling interval (once in 300 sec).
EXOS-20429 FDB entries learned on NetLogin-enabled bridge port extender (BPE) ports point to the CPU causing traffic loss.
EXOS-20251 BFD sessions on the Default VLAN go down after enabling hardware-assist BFD,
EXOS-24128 Need to allow RESTCONF GET requests for user-level accounts.
EXOS-24120 When refreshing policy files, process HAL ends unexpectedly with signal 11.
ExtremeSwitching X695 Series Switches
EXOS-20029, EXOS-19978 Stacks with IPv6-to-IPv4 or IPv6-in-IPv4 tunnels may experience traffic loss or slowpath if a VLAN with a tunnel has its VLAN tag changed dynamically using the command configure vlan vlan_name tag new_tag.
EXOS-19637 On ExtremeSwitching X695 series switches, with ECMP enabled for the VXLAN overlay network, deleting static overlay routes produces a shadow problem error and traffic is stopped.
EXOS-19532 On ExtremeSwitching X695 series switches, VMAN over VXLAN is not supported.
EXOS-19367 On ExtremeSwitching X695 series switches, the command "show process group" displays CPU utilization of the "Other" group tasks also under the "EXOS" group.
EXOS-19359 On ExtremeSwitching X695 series switches, "Other" group CPU utilization does not appear accurately in the show process group command.
ExtremeSwitching X440-G2 Series Switches
EXOS-19349, EXOS-24065 After rebooting ExtremeSwitching X440G2-12p switches, port-related warning logs appear.
ExtremeSwitching X465 Series Switches
EXOS-18535 Hot-swapping the fans might result in the appearance of i2c optic error messages.
EXOS-24101 SCP sync fails on backup node when downloading an image.
ExtremeSwitching X590 Series Switches
EXOS-26209 Continuous multicast entry additions and deletions produce IPMC error messages.
ExtremeSwitching X435 Series Switches
EXOS-24245 Not able to upgrade ExtremeSwitching X435 series switches through Chalet File App Manager.
EXOS-24237 For ExtremeSwitching X435 series switches, Python errors occur when running show vid command.
ACL
EXOS-24087 Policy with attribute "replace-vlan-id" fails to be installed sometimes and the error message 'No resources for the "replace-vlan-id" option' appears.
Bidirectional Forwarding Detection (BFD)
EXOS-20096 When switches are rebooted with the loopback port disabled, BFD sessions remain in init state.
EXOS-20533 Hardware-assist BFD session goes down after changing the egress VLAN tag.
Extreme Loop Recovery Protocol (ELRP)
EXOS-10881 Configuring Extreme Loop Recovery Protocol (ELRP) a very large number of ports results in rejection of the command with the message Configuration reply is too big.
EVPN
EXOS-19816 When VXLAN service VLAN ports go down, BGP.PolicyMgr.RtNotAdvertNHSameTxPeer warning message appears.
Extended Edge Switching
EXOS-20472 Extended Edge Switching with MLAG configurations become unstable when NetLogin is configured on bridge port extender (BPE) trusted ports.
EXOS-20471 VPEX process ends unexpectedly with signal 11 due to invalid cascaded port configuration.
EXOS-20419 FDB entries learned on NetLogin-enabled bridge port extender (BPE) ports point to the CPU causing traffic loss.
EXOS-20156 With a large amount of multicast traffic on an Extended Edge Switching ring with controlling bridge (CB) MLAG setup, traffic loss and duplicates occur after rebooting a CB.
EXOS-19715 On V300 bridge port extenders (BPEs), OSPFv3 sessions are flapping with 1G link.
EXOS-26534 In Extended Edge Switching with MLAG topology, bridge port extender (BPE) port is not joining a LAG.
EXOS-24070 On Extended Edge Switching topologies, the output of the show port description command displays truncated port numbers of extended slots.
Fabric Attach
EXOS-20325 The proper behavior of an Fabric Attach (FA) proxy, when connected to a single FA server, having the FA server to transition to FA proxy, and then the original proxy becoming an FA client is not occurring.
EXOS-20113 For Fabric Attach-created dynamic management VLANs, manually disabling DHCP does not work.
EXOS-19674 Static NSI bindings go into the pending state when dynamic binding with identical NSI is removed.
EXOS-19319 On Fabric Attach with MLAG configurations, failover times after switch reboot is slightly increased and needs to be reduced.
EXOS-17727 The command clear counters is not clearing fabric attach statistics.
EXOS-16564 If a VLAN in the client is deleted, or if the client is not reachable, the corresponding NSI mappings should timeout at the same time on the MLAG proxy peers, but this is not occurring.
EXOS-20492 Mgmt VLAN information under Fabric Attach gets updated only after receiving second LLDP packet.
EXOS-20302 With an ExtremeSwitching X670-G2 SummitStack acting as a Fabric Attach proxy, you cannot create a VLAN with "v" in the name along with the system VLAN tag number. For example, if the system VLAN is "SYS_VLAN_0200", trying to create a VLAN named "v200" produces an error message stating that the VLAN already exists.
MLAG
EXOS-24289 When reassembling the fragmented packets, kernel crashes occur randomly,
EXOS-24130 Need a mechanism to bring up MLAG ports in a staggered manner.
MPLS
EXOS-24040 With SRP configured on VPLS service VMAN, when a primary or secondary port goes down, the other port is not passing traffic through the tunnel.
Network Login
EXOS-19000 Authenticated NetLogin user's entries are flushed when new member port is added into a LAG group.
EXOS-24112 LLDP packets are not sent and received after successful NetLogin authentication.
EXOS-24088 With NetLogin multiauth mode configured, MAC users are logged as "Unknown" user during un-authentication.
OSPF
EXOS-20578 When default routes are installed with IP route compression enabled, traffic loss occurs.
EXOS-26245 OSPF sends same instance of LSA twice in single LS update resulting in traffic loss.
PoE
EXOS-26118 On SummitStacks with PoE-capable switches, running the show tech command causes the PoE process to end unexpectedly.
Policy
EXOS-20246 With ONEPolicy configured, ARP responds are sent with the incorrect VLAN tag when receiving multicast packets on the inactive VLAN.
STP
EXOS-26491 In STP, root switch becomes isolated when root bridge goes down.
SummitStack
EXOS-20349 After enabling VRRP on SummitStacks, source address in ARP packets originated on the Management interface are sent with VRRP Virtual MAC addresses.
EXOS-24094 On SummitStacks, when check pointing CFM messages in backup node, dot1ag process ends unexpectedly at random times.
EXOS-20334 Synchronize stacking command fails to synchronize the stack.
EXOS-10879 In SummitStacks, HAL process spike occurs on master node when standby node power is lost.
VXLAN
EXOS-20153 Need EMS or error log message for when multiple VXLAN RTEP nexthops are pointing to the same interface.
EXOS-16574 In the ExtremeXOS User Guide, need to add a note regarding limitation with VXLAN overlay routing.