Resolved Issues in ExtremeXOS 30.7.1-Patch1-54

The following issues were resolved in ExtremeXOS 30.7.1-Patch1-54. ExtremeXOS 30.7.1-Patch1-54 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.7.1-Patch1-54
Defect Description
General
EXOS-27157 HAL process ends unexpectedly on master node of SummitStack if stacking-related show commands are run when some other stacking slot is being unconfigured.
EXOS-26783 The command disable stpd s0 appears twice in the configuration if STP is disabled and if the default ST[D mode of s0 domain is changed.
EXOS-27088 SSH does not work with weaker public key-algorithm ssh-dss.
EXOS-27541 The process exsshd might end unexpectedly when closing an SSH connection.
EXOS-27202 ExtremeXOS adds a prefix of csr- to the common name in the Certificate Sign Request (CSR).
EXOS-27226 During VPLS fallback scenario, convergence happens within a second, which causes communication loss between CE devices.
EXOS-27341 If a non-tenant VMAN is added to the same port as CEP, then you are not able to ping the tenant VLAN IP on a VTEP.
EXOS-27285 Default-originate routes stop being transmitted over BGP/OSPF when BGP redistribute cost is high.
EXOS-26378 FDB is not learned on network VLANS when L2VPN sharing is not enabled on PE switches.
EXOS-27152 When there are flaps on MPLS cloud, VPLS FDB is leaked on network VLAN.
EXOS-27068 After a reboot, switch fails to load VLAN configuration on a port with remote mirroring configured.
EXOS-27044 Invalid entity warnings appear in log after ExtremeCloud request.
EXOS-27427 JSON request for a configuration change or save (admin privilege) fails for RADIUS-authenticated users.
EXOS-26430 Fabric Attach uplink is not added/removed in static/dynamic VLAN based on NSI status.
EXOS-27390 Installation of ACL rule entries containing multiple conditions of the same match type should be blocked.
EXOS-27041 TTL match condition is not updated during ACL smart refresh.
EXOS-27258 The show configuration difference command output incorrectly shows differences when the booted and the running configuration are identical.
EXOS-27268 On Extended Edge Switching topologies, pibAsicUpdOneDot1brPortEgressReplication' error messages appear when upgrading to ExtremeXOS 30.7.
EXOS-27126 VPEX process ends unexpectedly after unconfiguring and reconfiguring the extended slot (V300).
EXOS-27169 If switch is configured with slot:port notation, cable diagnostic script returns errors.
EXOS-27011 The process cliMaster ends unexpectedly when any show command is run with grep option and log target session is enabled.
EXOS-27098 In the output of the show stpd command, the operational edge status is not set to "true" for ports linked up at non-default speeds, such as 100M or 10M.
EXOS-27006 Nettools process ends unexpectedly when receiving DHCP packets with invalid DNS (0.0.0.0).
EXOS-27085 Inter-VLAN loops are not detected by ELRP on NetLogin VLANs when the port is set to MAC-based VLAN.
EXOS-27270 HAL process ends unexpectedly when ExtremeXOS retries detecting unsupported or third-party optics.
EXOS-26734 With loop present, FDB process ends unexpectedly after enabling ELRP hardware-assist feature.
SummitStack
EXOS-26963 Stacks do not come up successfully with default license if ExtremeSwitching X870/X695 series switches are mixed with other platform switches having master-capability set to on.
EXOS-27386 On SummitStacks, STP memory leak occurs on backup node for each MLAG port flap on peer switch.
ExtremeSwitching X435 Series Switches
EXOS-27082 ExtremeSwitching X435-8p switches remain in boot loop due to FDB process ending unexpectedly when upgrading to ExtremeXOS 30.7.1.1.