Resolved Issues in ExtremeXOS 30.7.2-Patch1-20

The following issues were resolved in ExtremeXOS 30.7.2-Patch1-20. ExtremeXOS 30.7.2-Patch1-20 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 30.7.2-Patch1-20
Defect Description
General
EXOS-28558 Multicast traffic loss seen in VPEX setup after a reboot of an extended slot.
EXOS-28737 IPv6 Neighbor discovery fails intermittently on MLAG peer.
EXOS-28891 When the "Extreme Entrasys entity sensor MIB" is polled, incorrect Tx/Rx power threshold values are returned.
EXOS-29106 Default route shows "Unfeasible" flag after IBGP adjacency flap of peer switch when multipath is configured.
EXOS-29134 VPEX ring not detected due to missing ECID in extended slot after a reboot of the controlling bridge.
EXOS-29208 The switch does not skip the lines starting with "#" in the .lst files.
EXOS-29235 cliMaster process consumes high CPU after disabling BFD and terminating the SSH session running BFD statistics.
EXOS-29283 Multicast traffic duplication observed in VPEX-MLAG setup after link flap of ports in VPLAG.
EXOS-29284 L2 traffic gets flooded in MLAG due to a miss in FDB checkpointing between MLAG peers.
EXOS-29298 Multicast traffic loss seen in VPEX setup after a reboot of an extended slot.
EXOS-29308 Egress vlan statistics is not fetching counters for port numbers greater than 64.
EXOS-29379 BGP flag is not set correctly in the IPv6 BGP table after flapping the port on the peer switch.
EXOS-29380 VPEX ring stuck in Severed state after BPE reboot due to LACP aggregation failure on the cascade port.
EXOS-29418 Traffic destined to the subnet IP is broadcast on all the ports present in the destination VLAN.
ExtremeSwitching X465
EXOS-29381 Perpetual PoE does not work with Igor PD.
ExtremeSwitching X695
EXOS-29295 When optics.xmod is installed on an ExtremeSwitching X695 series switch, an error message is displayed due to a particular missing file.
SummitStack
EXOS-27666 In a SummitStack, all of the FAN serial numbers are not shown under the show fan command.
EXOS-29179 The show fan command output is not aligned when executed in a backup node.
EXOS-29181 Slot reboot is occurs when a fan is removed from the SummitStack.
EXOS-29182 In SummitStacks, there needs to be support for the active monitoring of fan status/failures.
EXOS-29259 The backup slot is never in sync when the diagnostics command is started on a stack port during slot reboot.