The following issues were resolved in ExtremeXOS 30.7.3. ExtremeXOS 30.7.3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.
Defect | Description |
---|---|
General | |
EXOS-30189 | The rtmgr process ends unexpectedly when running the disable/enable bgp command. |
EXOS-30438 | OSPF signal 11 crash occurs when the switch tries to generate an External LSA after an LSDB change. |
EXOS-30837 |
The following error is seen when attempting to download an image when the switch real time clock has a time set that is older than the image being installed: Error: Failed to download image - Certificates verification failed; Image signature validation will be bypassed. |
EXOS-31037 | After configuring VXLAN and rebooting the switch, the ACL feature unavailable error is seen when trying to apply an ACL. |
EXOS-31074 | A redistributed EBGP route is not advertised by OSPF after issuing the restart ports all command. |
EXOS-31148 | With a next-hop matching condition, ACL refresh is not working when a new matching condition is added to the same. |
EXOS-31190 | Silent reboots occur in ExtremeSwitching X870, X690, and X590 platform switches. |
EXOS-31195 | Multicast packet loss and PIM register drops occur on an RP switch when MPLS is enabled. |
EXOS-31241 | The Policy process crashes with signal 6 while processing a TCP DNS response packet. |
ExtremeSwitching X870 Series Switches | |
EXOS-31034 | On X870 series switches, fan failure logs are reported even with the RPM being within a 10% tolerance of the maximum allowed range. |