The following issues were resolved in ExtremeXOS 30.7.2-Patch1-58. ExtremeXOS 30.7.2-Patch1-58 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.
Defect | Description |
---|---|
General | |
EXOS-29353 | Display the debug packet capture status under the show tech-support command. |
EXOS-29579 | Unable to ping directly connected hosts on a specific VLAN due to a missing local route in the hardware. |
EXOS-29730 | Switch doesn't forward the broadcast/ARP packet after ZTP installs an ACL to lift the DHCP packet. |
EXOS-29791 | Unable to configure a /24 subnet IP address when a /32 loopback address is already present. |
EXOS-29862 | SSH connection refused to connect after stack failover. |
EXOS-29866 | Unable to change the partition in ports 49, 50, 101, and 102 if sharing is enabled on any of the adjacent ports (for example, ports 51, 52, 103, and 104). |
EXOS-29892 | Unable to retrieve the slot description via SNMP. |
EXOS-29924 | The switch doesn't ask for the correct password again when a password mismatch happens while the created account is in enhanced security mode. |
EXOS-29979 | VPLS/VPWS Improper ARP handling. |
EXOS-30031 | DHCP offer and acknowledgement packets are broadcast on all sub-VLANs when the switch acts as a relay agent. |
EXOS-30044 | Unconfigure IPv4 address using VLAN ID is not working. |
EXOS-30050 | eVPN: LTEP IP and reversed LTEP IP added to BGP as network. |
EXOS-30068 | The vlan keyword is missing in the configuration display for VLANs containing IPv6 addresses. |
EXOS-30102 | Fix for vulnerability mentioned in CVE-2021-33909. |
EXOS-30114 | Traffic loss for more than 5 seconds observed after primary link failure with ospfv3 spf-hold-time 0 configuration. |
EXOS-30123 | Need support to turn on NTP from VRF-type VR context to have the same behavior as ExtremeXOS 30.2. |
Extreme Switching X670-G2 Series Switches | |
EXOS-29773 | VXLAN: Tunnel with remote endpoint and local endpoint is operationally down for unicast. |
Extreme Switching X690 Series Switches | |
EXOS-29423 | With port a partition template of 4x100G applied on the switch, ports 49-53 are occasionally displayed in "R" state instead of in "NP" state. |
Extreme Switching X695 Series Switches | |
EXOS-29959 | The show configuration command does not display the speed setting of 100G-capable ports. |
SummitStack | |
EXOS-30025 | The CLI session in SummitStack gets locked while saving the configuration if save configuration as-script <filename> is previously executed in the same stack prior to the backup/standby nodes boot up. |