This release incorporates all fixes from prior releases, up to and including VOSS 8.5.2.0, VOSS 8.6.1.2 and VOSS 8.7.0.1.
Issue number |
Description |
---|---|
VOSS-22264 |
Sending traffic from duplicate DvR hosts over a long period of time can cause errors. |
VOSS-22445 | Duplicate DvR hosts trigger loop leading to VMem reaching critical level of 90% utilization on x86 and crashing. |
VOSS-22848 |
Host entry displays at the original location when you migrate a DvR host to another domain. |
VOSS-23130 | Migrating to DvR and then reverting back to L2 VLAN, left ARP entry in the IO table and not cleaned up. |
VOSS-23158 | In a DvR network, when the Controllers' default route is deleted, all the DvR leaf nodes become unreachable. |
VOSS-24742 |
A port remains down if you do not synchronize the system clock, or if it fails to synchronize, with the NTP current time. |
VOSS-24952 | TACACS+ Client sends optional remote-address field in authentication/authorization/accounting requests but instead of putting the user IP address in it, places the switch's own IP address. Starting with 8.8, it correctly puts user IP address in it. |
VOSS-25001 |
DvR & IPv6 VRRP : IPv6 connectivity issue (ping or management traffic) between VIST partners on a vlan with both DvR and IPv6 enabled when a MLT is added in that vlan. |
VOSS-25043 | VSP 7400 Series - Frequent IST flapping when running security scans. |
VOSS-25689 | XA1440: dropping packets internally from secondary BEB. |
VOSS-25788 | IP multicast can fail for vlans with EAP ports after DvR leaf losses/restores connectivity to Controllers. |
VOSS-25829 |
When you configure only one CPU core and 1 Gbps memory on the VSP 4900 Series, VSP 7400 Series, and 5720 Series, the virtual service does not operate properly because CPU and memory resources configured in the .ova OVF file exceed the resources on the switch. |
VOSS-26023 | Enhance broadcast/multicast rate limiting to include unknown unicast traffic. |
VOSS-26119 | Output of show eapol port interface is now split into two separate tables to reduce the output width. |
VOSS-26130 | Consistency check added for SPBM STP-Multihoming so that it can only be enabled with STP versions MSTP. |
VOSS-26207 | In some scenarios, multipath group stale entries are still seen after IS-IS bouncing on neighbor BEB. |
VOSS-26214 |
On the XA1400 Series, you cannot configure more than one IPsec responder-only tunnel when fragmentation before encryption is enabled. Only one Fabric Extend tunnel establishes in this scenario. |
VOSS-26266 | Memory leak in NLS processing. |
VOSS-26309 | DvR GW-MAC not updating on newly configured controller. |
VOSS-26488 | EDM, port auto-sense state and settings now included in auto-sense sub tab. |
VOSS-26495 |
MACsec is not supported on VIM-2CE when the ports operate at 100 Gbps due to FCS errors. |
VOSS-26511 | VSP 7200 Series: Valid Evaluation PLDS Premier license stopped working after switch reboot. |
VOSS-26532 | Remove the NNI-PENDING state and to form adjacencies through Auto-sense in the Home area. So, each time a FC TLV is received, the port will be configured as NNI in the home area. It is the user responsibility to disable Auto-Sense on the IS-IS Remote Area ports. |
VOSS-26566 | VLAN IP address not reachable if the VLAN is configured through ExtremeCloud IQ ‑ Site Engine. |
VOSS-26593 | Memory leak due due to syslog-ng logging, as it did not rotate the logs and filled up the available memory. |
VOSS-26700 | VRF name of ip-tunnel-source-address got lost after a power reset. |
VOSS-26756 | DvR hosts intermittently become unreachable after a VMotion move due to missing Layer 3 HW entries on DvR leaves. |
VOSS-26779 | XA1440: Crash seen at boot when having IPsec configured in decoupled mode and router isis disabled. |