The following issues were resolved in Switch Engine 32.7.1. Version 32.7.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, and 32.6.x.
Defect Number | Description |
---|---|
General | |
CFD-9602 | When a new dot1x client is authenticated on a port, the accounting stop is not sent for the old dot1x client and the accounting start is not sent for the new client. |
CFD-9616 | Router-discovery configurations were missing after disabling/enabling VRRP instance. |
CFD-9636 | Static fdb VxLAN entry is programmed with 30 minutes delay after switch restarts, even when the VxLAN tunnel is UP. |
CFD-9690 | Error message is not generated when there are failures in installing ACL rules enforced from XIQ-SE though policy profile. |
CFD-9694 | ACL Signal 11 crash is observed when ACL is added from a script and the process crash causes a switch reboot. |
CFD-9882 | IDmgr critical log was seen when flapping the port with 1000+ dynamically created VLANs. |
CFD-9919 | Switch restarts because of a kernel crash. |
CFD-9973 | CLI session hangs when applying PBR policy whose file name is 32 characters, and when file name exceeds 32 characters policy check fails. |
CFD-9996 | On a stack, the backup and Standby Slot port configuration information is not returned when ExtremePortConfigTable is polled. |
CFD-10072 | VRRP hello's were dropped when its forwarded over ISC. |
CFD-10120 | SNMP traps were not getting generated when there is an IP Security ARP violation despite the corresponding configuration being present in the switch. |
CFD-10255 | Netlogin Client not learnt on port after STP convergence. |
CFD-10300 | FDB process crash was seen when polling fdb.ipNetToPhysicalEnt MIB. |
CFD-10311 | A local file will be used to restore DHCP-binding information if the remote server is unreachable. |
CFD-10352 | Policy (.pol) files imported via the "Download URL" command are not synced to the backup node on summit stack switches. |
CFD-10416 | rtmgr process crash was seen when enabling BFD on ipv6 prefix. |
CFD-10466 | SSH-RSA public key authentication method fails with error "no mutual signature algorithm" in SSH client. |
CFD-10474 | unconfigure switch all does not remove the configure system port notation setting |
CFD-10475 | Netlogin allowed-uses does not work as expected. |
CFD-10494 | mcmgr process crash was seen when fast-leave is enabled and receiving leave message. |
CFD-10575 | Error was seen when executing config account admin encrypted <pwd> command. |
CFD-10583 | .cfg file transferred to swtich not available for use until reboot or copied to another file. |
CFD-10613 | Resource leak was seen in the hardware when deleting all ports in a VLAN. |
CFD-10614 | SSH key becomes invalid sometimes during the reboot of the switch. |
CFD-10688 | Accounts created using encrypted password, the expiry date was not shown. |
CFD-10754 | XML-Notification was not sent with the configured source IP. |
CFD-10781 | ACL process crash was seen when applying a policy with match condition OSPF on the VLAN. |
CFD-10816 | User list in Chalet becomes empty/blank when the number of users is one. |
CFD-10918 | L2VPN service name with 32 characters can hang CLI session. |
CFD-10946 | Switch brings up the ports when diagnostics tests are running. |
CFD-10968 | MVRP VLAN is not check-pointed to the MLAG peer when the corresponding remote MLAG port is inactive. |
CFD-11018 | Polling the dot1dTpFdbTable information through SNMP returns the value with an additional octet. |
CFD-11160 | Memory leak is observed in VLAN process when there are port flaps. |
EXOS-31480 | After a stack restart, a 25 Gbps port inserted with a 10 Gbps 10301 optic transceiver goes down in Backup and Standby nodes. |
EXOS-31609 | Loop is observed in MLAG topology when MACSEC is enabled on MLAG ports. |
EXOS-32500 | DM error was seen when sending IPARP packets more than configured entries. |
EXOS-32696 | File uploaded from Chalet are not synced with the backup slot |
EXOS-33307 | Dot1x clients are randomly admin-reset as soon as they are authenticated. |
EXOS-33850 | Stack was rebooted after executing disable/enable mirror when stack port was added as loopback port in mirroring. |
EXOS-35861 | "Supported Limits" will need to change to TBD values for 7520/7720 IPv4 and IPv6 routes in hardware. (Perhaps 256K IPv4 and 128K IPv6 64-bit, depends on test results). |
5420 Series | |
EXOS-31480 | After a stack restart, a 25G port inserted with 10G 10301 optic transceiver goes down in Backup and Standby nodes. |
EXOS-34033 | On the multi-rate ports of a 5420 switch, the link randomly comes up at 100M after a Link flap. |
5520 Series | |
CFD-9546 | Ports inserted with 100Fx# optics in the backup/standby nodes of a stack go down after restarting the nodes. |
CFD-11017 | In 5520-24x platform switches, 100MB link goes down after the switch restarts. |
7720 Series | |
CFD-11027 | Multicast error logs "Unable to Del L2" are seen when ports that are in "NP" state are added to LAG group. |
Summit Stack | |
CFD-9627 | Image was not synced to standby node in the stack when copying the image by using SFTP put in the server. |
CFD-9840 | MLT session was not up after enable/disable jumbo-frames when EXOS stack is enabled with VPEX. |
CFD-10056 | Error message was seen when creating LAG with Master and backup node VIM ports. |
CFD-10508 | ARP probe packets are sent from the backup slot in a stack with its own physical MAC-address as the source-address. |
CFD-10647 | Switch started to respond for ARP requests with source MAC address as all zeroes or VRRP MAC. |
VPEX | |
CFD-9531 | The show tech-support gets stuck at "show vpex" command with specific VPEX configuration. |
CFD-9884 | HAL process crash was seen when sending multicast packets to more than 33 BPEs and when disabling/enabling the ports in a BPE. |