rmon/alarm

Configures Remote Monitoring Protocol (RMON) alarm.

Usage

<rmon xmlns="urn:brocade.com:mgmt:brocade-rmon">
	<alarm-entry>
		<alarm-index>5</alarm-index>
		<snmp-oid>1.3.6.1.2.1.16.1.1.1.5.65535</snmp-oid>
		<alarm-interval>30</alarm-interval>
		<alarm-sample>absolute</alarm-sample>
		<alarm-rising-threshold>195</alarm-rising-threshold>
		<alarm-rising-event-index>25</alarm-rising-event-index>
		<alarm-falling-threshold>95</alarm-falling-threshold>
		<alarm-falling-event-index>27</alarm-falling-event-index>
		<alarm-owner>john_smith</alarm-owner>
	</alarm-entry>
</rmon>

Parameters

alarm-index
Specifies the alarm index. The value can range from 1 through 65535.
snmp-oid
Specifies sampling object SNMP OID.
alarm-interval
Specifies alarm interval. The interval can range from 1 through 2147483648 seconds.
alarm-sample
Specifies alarm sample type.
absolute
Sample type absolute.
delta
Sample type delta.
alarm-rising-threshold
Specifies alarm rising threshold value. The value can range from 0 through 4294967295.
alarm-rising-event-index
Specifies event index for rising threshold. The value can range from 1 through 65535.
alarm-falling-threshold
Specifies alarm falling threshold value. The value can range from 0 through 4294967295.
alarm-falling-event-index
Specifies event index for falling threshold. The value can range from 1 through 65535.
alarm-owner
Specifies the owner identity.