rmon/alarm
Configures Remote Monitoring Protocol (RMON) alarm.
Usage
<rmon xmlns="urn:brocade.com:mgmt:brocade-rmon">
<alarm-entry>
<alarm-index>5</alarm-index>
<snmp-oid>1.3.6.1.2.1.16.1.1.1.5.65535</snmp-oid>
<alarm-interval>30</alarm-interval>
<alarm-sample>absolute</alarm-sample>
<alarm-rising-threshold>195</alarm-rising-threshold>
<alarm-rising-event-index>25</alarm-rising-event-index>
<alarm-falling-threshold>95</alarm-falling-threshold>
<alarm-falling-event-index>27</alarm-falling-event-index>
<alarm-owner>john_smith</alarm-owner>
</alarm-entry>
</rmon>
Parameters
- alarm-index
- Specifies the alarm index. The value can range from 1 through 65535.
- snmp-oid
- Specifies sampling object SNMP OID.
- alarm-interval
- Specifies alarm interval. The interval can range from 1 through 2147483648 seconds.
- alarm-sample
- Specifies alarm sample type.
- absolute
- Sample type absolute.
- delta
- Sample type delta.
- alarm-rising-threshold
- Specifies alarm rising threshold value. The value can range from 0 through 4294967295.
- alarm-rising-event-index
- Specifies event index for rising threshold. The value can range from 1 through 65535.
- alarm-falling-threshold
- Specifies alarm falling threshold value. The value can range from 0 through 4294967295.
- alarm-falling-event-index
- Specifies event index for falling threshold. The value can range from 1 through 65535.
- alarm-owner
- Specifies the owner identity.