rmon alarm 
 
   
  Sets the RMON alarm conditions. 
  
 Syntax
 
	  
		rmon alarm 
		 
		  index 
		  snmp_oid 
		  interval 
		  seconds 
		  [ 
		  absolute 
		  | 
		  delta 
		  ] 
		  rising-threshold 
		  value 
		  event 
		  number 
		  [ 
		  falling-threshold 
		  value 
		  event 
		  number 
		  [ 
		  owner 
		  name 
		  ] 
		 
	 
 
	 
  
	 Command Default
 
		 No alarms are configured. 
		
 
	 
 
	 Parameters
 
		 
		   
			 -  
				 
				  index 
				 
			 
  
			 - Specifies the RMON alarm index. Valid values range from 1 through 65535. 
			 
  
		   
		   
			 -  
				 
				  snmp_oid 
				 
			 
  
			 - Specifies the MIB object to monitor. The variable must be in the SNMP OID format, for example, 1.3.6.1.2.1.16.1.1.1.5.65535. The object type must be a counter32. 
			 
  
		   
		   
			 -  
				 
				  interval 
				  seconds 
				 
			 
  
			 - Specifies the RMON alarm sample interval in seconds. Valid values range from 1 through 2147483648. 
			 
  
		   
		   
			 -  
				 
				  absolute 
				 
			 
  
			 - Sets the sample type as absolute. 
			 
  
		   
		   
			 -  
				 
				  delta 
				 
			 
  
			 - Sets the sample type as delta. 
				
 
				   
					 - rising-threshold 
						  value 
					 
  
					 - Specifies the RMON alarm rising threshold. Valid values range from 0 through 4294967295. 
					 
  
				   
				   
					 - event 
						  number 
					 
  
					 - Specifies the event for the rising alarm. Valid values range from 1 through 65535. 
					 
  
				   
				   
					 - falling-threshold 
						  value 
					 
  
					 -  Specifies the RMON alarm falling threshold. Valid values range from 0 through 4294967295. 
					 
  
				   
				   
					 - event 
						  number 
					 
  
					 - Specifies the event for the rising alarm. Valid values range from 1 through 65535. 
					 
  
				   
				   
					 - owner 
						  name 
					 
  
					 - Specifies the identity of the owner. The maximum number of characters is 32. 
					 
  
				   
				
 
			   
		   
		
 
	 
 
	 Modes
 
		 Global configuration mode 
		
 
	 
 
	 Usage Guidelines
 
		 Enter 
		  no rmon alarm to disable the alarm conditions. 
		
 
	 
 Examples
 
	  
		 To set RMON alarm conditions: 
		
 
		device# configure terminal
device(config)# rmon alarm 100 1.3.6.1.2.1.16.1.1.1.5.65535 interval 5 absolute rising-threshold 10000 event 100 falling-threshold 1000 event 101 owner admin