Upgrade the SLX 9540 CPLD Image

  1. Confirm that the peripheral software (firmware) requires an upgrade.
    If the dates are not identical, the software must be upgraded.
    device# show firmware peripheral cpldSLX# show firmware peripheral cpld
    
    +---------------+----------------------+-------------------------------+
    |     Type      |   Current Version    |   Latest Version Availalble   |
    +---------------+----------------------+-------------------------------+
    |    CPLD0      |    02/09/2017(93)    |        02/09/2017(93)         |
    +---------------+----------------------+-------------------------------+
    |    CPLD1      |    02/09/2017(93)    |        02/09/2017(93)         |
    +---------------+----------------------+-------------------------------+
  2. Update the software.
    Both units are upgraded automatically.
    device# firmware peripheral-update cpld
    erasing ….. done
    programing …….…….…….……. 25% …………….…….……. 50% .......…….…….…… 75% …………………………. 100%
    cpld0 image is upgraded successfully.
     
    erasing ….. done
    programming …….…….…….……. 25% …………….…….……. 50% .......…….…….…… 75% …………………………. 100%
    cpld1 image is upgraded successfully.
  3. Reboot the device.
    device# reload system
  4. Verify that the units were upgraded.
    The dates should be identical.
    device# show firmware peripheral cpld
    +----------+----------------+----------------+
    |  Type    | Current Version| Latest Version |
    +----------+----------------+----------------+
    |  CPLD0   | 02/09/2017(93) | 02/09/2017(93) |
    +--------- +----------------+----------------+
    |  CPLD1   | 02/09/2017(93) | 02/09/2017(93) |
    +--------- +----------------+----------------+