Power Consumption
The following tables include power consumption information for the 8520 Series
switches.
8520-48Y
The following tables provide AC and DC power consumption information for the 8520-48Y
switch models.
Table 1. AC IN: 220V
Item |
Test Mode |
Consumption (W) |
Notes |
Dual Power |
Single Power |
PSU1 |
PSU2 |
1 |
Empty Model |
109 |
104 |
207 |
- No fiber transceivers inserted
- No port up link
- 85% fan duty
|
2 |
Standby Model |
114 |
108 |
216 |
- All ports up link
- 85% fan duty
|
3 |
Typical Model |
121 |
116 |
232 |
- Snake test with 70% traffic load (1518 byte packet
length)
- 85% fan duty
|
4 |
Stress Model |
154 |
148 |
299 |
- Snake test with 100% traffic load (64 byte packet
length)
- 100% fan duty
|
Table 2. AC IN: 110V
Item |
Test Mode |
Consumption (W) |
Notes |
Dual Power |
Single Power |
PSU1 |
PSU2 |
1 |
Empty Model |
112 |
106 |
209 |
- No fiber transceivers inserted
- No port up link
- 85% fan duty
|
2 |
Standby Model |
118 |
111 |
223 |
- All ports up link
- 85% fan duty
|
3 |
Typical Model |
126 |
119 |
239 |
- Snake test with 70% traffic load (1518 byte packet
length)
- 85% fan duty
|
4 |
Stress Model |
158 |
152 |
302 |
- Snake test with 100% traffic load (64 byte packet
length)
- 100% fan duty
|
Table 3. DC IN: 48V
Item |
Test Mode |
Consumption (W) |
Notes |
Dual Power |
Single Power |
PSU1 |
PSU2 |
1 |
Empty Model |
130 |
100 |
226 |
- No fiber transceivers inserted
- No port up link
- 85% fan duty
|
2 |
Standby Model |
134 |
104 |
235 |
- All ports up link
- 85% fan duty
|
3 |
Typical Model |
141 |
111 |
251 |
- Snake test with 70% traffic load (1518 byte packet
length)
- 85% fan duty
|
4 |
Stress Model |
178 |
145 |
325 |
- Snake test with 100% traffic load (64 byte packet
length)
- 100% fan duty
|
8520-48XT
The following tables provide AC and DC power consumption information for the
8520-48XT switch models.
Table 4. AC IN: 220V
Item |
Test Mode |
Consumption (W) |
Notes |
Dual Power |
Single Power |
PSU1 |
PSU2 |
1 |
Empty Model |
148.5 |
136 |
275.5 |
- No fiber transceivers inserted
- No port up link
- 85% fan duty
|
2 |
Standby Model |
155.8 |
143 |
289 |
- All ports up link
- 85% fan duty
|
3 |
Typical Model |
162.2 |
148 |
302.5 |
- Snake test with 70% traffic load (1518 byte packet
length)
- 85% fan duty
|
4 |
Stress Model |
204.8 |
189 |
389.5 |
- Snake test with 100% traffic load (64 byte packet
length)
- 100% fan duty
|
Table 5. AC IN: 110V
Item |
Test Mode |
Consumption (W) |
Notes |
Dual Power |
Single Power |
PSU1 |
PSU2 |
1 |
Empty Model |
149.8 |
138 |
250 |
- No fiber transceivers inserted
- No port up link
- 85% fan duty
|
2 |
Standby Model |
156.8 |
145 |
262 |
- All ports up link
- 85% fan duty
|
3 |
Typical Model |
164 |
151 |
275 |
- Snake test with 70% traffic load (1518 byte packet
length)
- 85% fan duty
|
4 |
Stress Model |
205 |
191 |
354 |
- Snake test with 100% traffic load (64 byte packet
length)
- 100% fan duty
|
Table 6. DC IN: 48V
Item |
Test Mode |
Consumption (W) |
Notes |
Dual Power |
Single Power |
PSU1 |
PSU2 |
1 |
Empty Model |
161 |
125 |
280 |
- No fiber transceivers inserted
- No port up link
- 85% fan duty
|
2 |
Standby Model |
168 |
132 |
295 |
- All ports up link
- 85% fan duty
|
3 |
Typical Model |
175 |
139 |
308 |
- Snake test with 70% traffic load (1518 byte packet
length)
- 85% fan duty
|
4 |
Stress Model |
221 |
184 |
399 |
- Snake test with 100% traffic load (64 byte packet
length)