Replace a Power Supply

The controller will support two power supplies, supplying hot-pluggable power redundancy. The system distributes the power load across both power supplies to maximize efficiency. When a power supply is removed with the system powered on, the full power load is picked up by the remaining power supply.
Note

Note

The system ships with just one power supply and you have the option to purchase the additional redundant power supply (Ordering Part No. 30527 WS-PSI-1100W-01).
Important

Important

The system requires one power supply to operate the system normally. Remove and replace only one power supply at a time when a system is powered on.
Each power supply has a single bi-color LED to indicate power supply status, as described in power supply status LED indicator patterns.
Table 1. Power supply status LED indicator patterns
Power supply condition Description
Output on and OK Green
No AC power to all power supplies Off
AC present/only 12VSB on (PS off) or PS in cold redundant state 1Hz blinking green
AC power cord unplugged or AC power lost. With a 2nd PS in parallel still with AC input power Amber
Power supply warning events where PS continues to operate - high temp, high power, high current, and slow fan 1Hz blinking amber
Power supply critical event causing a shutdown, failure, OCP, OVP, fan fail Amber
Power supply firmware updating 2Hz blinking green