View power information for the chassis.
show sys power [power-supply] [slot]
None
User EXEC
The show sys power commands display the following information:
Output field |
Description |
---|---|
Chassis Power Status |
Displays if the chassis contains redundant power. |
Chassis Type |
Displays the type of chassis. |
Total Chassis Power |
Displays the power currently used by the complete chassis. |
Required Redundant Power |
Displays the redundant power for the chassis. |
Max Allocated Power |
Displays the maximum power. |
Available Power |
Displays the available, unused, power. |
Reserved Power |
Displays the reserved power. |
Required Power |
Displays the required power. |
Power Supply |
Displays the power supply slot. |
Type |
Displays the type of power used. |
Input Voltage |
Displays the input line voltage. |
Serial Num |
Displays the power supply serial number. |
Part Num |
Displays the power supply part number. |
Oper Status |
Displays the status as on (up) or off (down). |
Max Power |
Displays the maximum power of the power supply. |
Fan FlowType |
Displays the airflow direction. |
Hardware Revision |
Displays the hardware revision number. |
Slot No. |
Displays the slot number. |
Present |
Displays if the slot is populated. |
CardType |
Displays the type of module in the slot. |
Priority |
Displays the priority of the slot for power management. |
Power Status |
Displays the status as on or off. |
Max Allocated Power |
Displays the power for the slot. |
The following example displays summary power information.
Switch:1#show sys power Chassis Power Status: non-redundant Total Required Max Chassis Chassis Redundant Allocated Available Reserved Required Type Power Power Power Power Power Power ------------------------------------------------------------------------------------------ 5320-48T-8XE-FabricEngine 90 0 75 15 75 75 ------------------------------------------------------------------------------------------
The following example displays detailed power information for each power supply.
Switch:1#show sys power power-supply ===================================================================================== Power Supply Information ===================================================================================== Power Type Input Serial Part Oper Max Fan Hardware Supply Voltage Num Num Status Power FlowType Revision --------------------------------------------------------------------------------------- PS#2 AC 110/220 2042U-30042 801094-00-01 UP 920 front-back 01 ---------------------------------------------------------------------------------------
The following example displays power information by slot.
Switch:1#show sys power slot ================================================================================ Slot Power Consumption ================================================================================ Max Slot Present CardType Priority Power Allocated No. Status Power -------------------------------------------------------------------------------- 1 YES 5420M-24W-4YE-FabricEngine CRITICAL ON 104 2 NO Not Present CRITICAL OFF 0 -------------------------------------------------------------------------------- ================================================================================ Chassis Power Information ================================================================================ Chassis Power Status: non-redundant Total Required Max Chassis Chassis Redundant Allocated Available Reserved Required Type Power Power Power Power Power Power -------------------------------------------------------------------------------------- 5420M-24W-4YE-FabricEngine 920 0 104 816 104 104 --------------------------------------------------------------------------------------