Displays the Auto-sense status and state on a port.
show interfaces gigabitethernet auto-sense [<1-4059>] [{slot/port[/sub-port][-slot/port[/sub-port]][,...]}]
Specifies the VLAN ID in the range of 1 to 4059. By default, VLAN IDs 1 to 4059 are configurable and the system reserves VLAN IDs 4060 to 4094 for internal use. On switches that support the vrf-scaling and spbm-config-mode boot configuration flags, if you enable these flags, the system also reserves VLAN IDs 3500 to 3998. VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1.
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.
None
Privileged EXEC
The show interfaces gigabitethernet auto-sense command displays the following information:
Output field |
Description |
---|---|
PORT NUM |
Displays the slot and port number. |
AUTO-SENSE STATUS |
Displays the administrative status of Auto-sense on the port. |
AUTO-SENSE STATE |
Displays the operational state of Auto-sense on the port. |
AUTO-SENSE PORT-DATA-ISID |
Displays the port Data I-SID, if configured. The port configuration takes precedence over a globally configured Data I-SID. |
AUTO-SENSE PORT-WAIT-INTERVAL |
Display the wait interval configured on the port. The port configuration takes precedence over a globally configured wait-interval. |
The following example displays the output for ports 1/1 through 1/5.
Switch:1>enable Switch:1#show interfaces gigabitethernet auto-sense 1/1-1/5 ====================================================================== Port Auto-sense ====================================================================== ---------------------------------------------------------------------- PORT AUTO-SENSE AUTO-SENSE AUTO-SENSE AUTO-SENSE NUM STATUS STATE PORT-DATA-ISID PORT-WAIT-INTERVAL ---------------------------------------------------------------------- 1/1 Enable DOWN -- 20 1/2 Enable DOWN -- 10 1/3 Enable DOWN -- 10 1/4 Enable DOWN -- 10 1/5 Disable OFF -- 10