In an Extended Edge Switching environment, shows the bridge port extender (BPE) topology that is connected to the specified native cascade port.
  | 
If a port is not specified, then summary (connected VPEX slot numbers only) information appears by default; if a port is specified, then detailed (VPEX slot interconnections) information appears by default.
If a port is not entered or summary is selected, all topologies appear (summary mode). Only the native cascade port or MLAG and a list of slots appear in summary mode.
If a port is entered or detail is selected, detailed mode information appears.
For slots configured using virtual MLAG, instead of the native cascade port, the MLAG ID appears.
The following example shows summary Extended Edge Switching topology information:
# show vpex topology
Topology: Cascade
  Native cascade port 1:45
    Slots: 104, 105, 106
Topology: Cascade
  Native cascade port 1:47
    Slots: 101, 102, 103
			The following example shows detailed Extended Edge Switching topology information:
# show vpex topology detail
Topology: Cascade
  Native cascade port 1:45
          Upstream  Cascade          Cascade
    Slot  Port      Port     Flags   Slot
    ----  --------  -------  ------  -------
    104   49        51               105
    105   49        51               106
    106   49        None             None
    ----  --------  -------  ------  -------
Topology: Cascade
  Native cascade port 1:47
          Upstream  Cascade          Cascade
    Slot  Port      Port     Flags   Slot
    ----  --------  -------  ------  -------
    101   49*       51*              102
    102   49*       51               103
    103   49        None             None
    ----  --------  -------  ------  -------
    * - Port is a member of a load sharing group
    Flags: (b) Backup Upstream Port, (B) Backup Cascade Port,
           (c) Common ring link on this BPE,
           (d) Dynamically Created Cascade Port,
           (E) Empty slot, (S) Severed ring link on this BPE.
		This command was first available in ExtremeXOS 30.3.
This command is available on the Summit X670-G2 and ExtremeSwitching X465, X690, X590 series switches.
Print
                        this page
Email this topic
Feedback