If you are upgrading an Extended Edge Switching configuration (controlling bridge (CB) and bridge port extenders (BPEs)) from either ExtremeXOS 22.7.1 or earlier or ExtremeXOS 30.2.1 or earlier to ExtremeXOS 30.3 or later, you cannot upgrade automatically using the combined .lst file. Instead, you must perform a manual upgrade. ExtremeXOS 22.7.1-Patch1-3 and later do not have this issue.
For more information about manual upgrades, see the Manual Upgrading section in the Extended Edge Switching Chapter in the ExtremeXOS 31.1 User Guide .
After this one-time upgrade, you can perform all subsequent ExtremeXOS upgrades automatically using the .lst file. For more information about automatic upgrades, see the Automatic Upgrading section in the Extended Edge Switching Chapter in the ExtremeXOS 31.1 User Guide .
# download image 192.0.2.99 onie-30.4.1.2-vpex_controlling_bridge.lst Note: The inactive partition (secondary) will be used for installation. Downloading tftp://192.0.2.99/onie-30.4.1.2-vpex_controlling_bridge.lst ................. Extracting /scratch/dnld/onie-30.4.1.2.xos from tftp://192.0.2.99/onie-30.4.1.2-vpex_controlling_bridge.lst Error: Cannot install /scratch/dnld/onie-30.4.1.2.xos. [Errno 28] No space left on device
Retry the upgrade using the manual upgrade procedure described above.
# run script shell.py "rm /scratch/dnld/*"