The following issues were resolved in ExtremeXOS 31.1. ExtremeXOS 31.1 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1, ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5, ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4, ExtremeXOS 30.5, ExtremeXOS 30.6, and ExtremeXOS 30.7. For information about those fixes, see the release notes for the specific release.
Defect Number | Description |
---|---|
General | |
EXOS-26648 | When you configure an explicit time using the configure time command, it might cause the switch to experience traffic loss or perform software forwarding instead of hardware forwarding. |
EXOS-26280 | After upgrading to ExtremeXOS 30.1, Identity Manager Kerberos snooping stops working. |
EXOS-19992 | On some ExtremeSwitching X440-G2 series switches, upgrading from ExtremeXOS 22.x to 30.3, or later, fails due to partition error. |
EXOS-27387 | JSON request for a configuration change or save (admin privilege) fails for RADIUS-authenticated users. |
EXOS-27305 | After receiving DHCP packets with invalid DNS(0.0.0.0), Nettools process ends unexpectedly. |
EXOS-27271 | When ExtremeXOS retries to detect unsupported or third-party optics, HAL process ends unexpectedly. |
EXOS-27256 | If a switch is configured with slot:port notation, the cable diagnostic script returns an error. |
EXOS-26895 | After upgrading to ExtremeXOS 22.7.2.4, multiple "Excessive MAC move" messages occur. |
ExtremeSwitching X690 Series Switches | |
EXOS-26689 | After configuring virtual network (L3VNI), Type 5 prefix routes are not installed, until after node reload prefixes are properly installed in the routing-table. |
ExtremeSwitching X440-G2 Series Switches | |
EXOS-27159 | ExtremeSwitching X440-G2 fan profile causes hyperventilating. |
EXOS-27121 | If any show command run with grep option and log target session is enabled, cliMaster process ends unexpectedly. |
ExtremeSwitching X670-G2 Series Switches | |
EXOS-26800 | During VPLS fallback scenario, convergence happens within a second, which causes communication loss between CE devices. |
ExtremeSwitching X465 Series Switches | |
EXOS-27040 | ExtremeXOS Ignores LLDP PDUs from auth-override (AP-Aware) ports. |
ExtremeSwitching X435 Series Switches | |
EXOS-26950 | For ExtremeSwitching X435 series 8-port switches, creation of user virtual routers with reserved keyword "VR-Mgmt" should be blocked. |
EXOS-26789 | On ExtremeSwitching X435 series switches, Zero Touch Provisioning (ZTP) using a USB drive does not work. |
EXOS-27209 | When upgrading to ExtremeXOS 30.7.1.1 from 30.5.0.239, switch stops during boot up with process fdb pid 1784 died with signal 11 error. |
EXOS-26917 | When accessing the Network Login base URL, ExtremeSwitching X435 series switches do not display the login page. |
ACL | |
EXOS-27153 | Installation of ACL rule entries containing multiple conditions of the same match type should be blocked. |
EXOS-26433 | Incorrect ACL is matched when using arp-sender-address in match condition. |
BGP | |
EXOS-26466 | BGP peers in non-VPN VRF do not recognize neighbors unless BGP progress is restarted. |
Extreme Loop Recovery Protocol (ELRP) | |
EXOS-26696 | ELRP disabled logs are not cleared even after enabling the disabled port. |
EVPN | |
EXOS-26671 | ARP routes for ExtremeXOS interface IPs are not installed in SLX leaf nodes. |
EXOS-26514 | CLI namespace for EVPN instances become unavailable after a node reboot. Therefore, you are unable to change the existing instances. |
Extended Edge Switching | |
EXOS-27458 | In Extended Edge Switching topologies, 'pibAsicUpdOneDot1brPortEgressReplication' error messages appear when upgrading to ExtremeXOS 30.7. |
Fabric Attach | |
EXOS-25872 | With Fabric Attach proxy and server configured as MLAG peers, with dynamic LAG (LACP) is configured between all the links, VLAN/NSI mappings are approved initially by the Fabric Attach server MLAG peers, but not after restarting all ports. |
OSPF | |
EXOS-26890 | Default-originate routes stop being transmitted over BGP/OSPF when BGP redistribute cost is high. |
PTP | |
EXOS-27222 | Need a provision to cancel out the correct field in pdelayresponse/pdelayresfollowup messages while calculating neighbor rate ratio. |
SummitStack | |
EXOS-27273 | Even with STP disabled, the STP process can cause memory depletion causing the backup slot to reboot. |
EXOS-26911 | The command show inline-power slot master_slot fails after a node is added or replaced with the automatic stacking. |
VPLS | |
EXOS-26524 | Service VLAN FDB entries are learned over network VLAN. |
VXLAN | |
EXOS-26562 | Not able to ping the tenant VLAN IP on a VTEP if a non-tenant VMAN is added to the same port as CEP. |
EXOS-19376 | When trying to configure Assisted Replicator role as Leaf, the following error
occurs:<Erro:HAL.VXLAN.Error> extreme_custom_vxlan_hal_batch_copy:998 AR_SVP_REPL_DEL with no ADD in batch |
EXOS-26896 | VXLAN error messages occur when incorrect ARP packets are received on tenant
VLAN:
04/12/2020 18:24:54.76 <Erro:HAL.VNet.Error> Failed to Add Net Port for RTEP:1 RtepAddr:192.168.253.2 LtepAddr:192.168.253.1 portType:2 err Generic Error 04/12/2020 18:24:54.76 <Erro:HAL.VXLAN.Error> Can not create BUM port in standard mode. |