The following are new open issues for supported features found in ExtremeXOS 31.4.

Table 1. Open Issues, Platform-Specific, and Feature Change Requests (CRs)
Defect Number Description
Universal Hardware
EXOS-29843 Booting a 5420F-24S switch with mirroring configured can result in the logging of HAL.Phy.FuncFail errors related to enabling port loopback. Similar errors are also seen when configuring mirror on ports with 10/100/1000T optics.

Workaround: Disable mirroring before rebooting the switch, and re-enable mirroring afterward. Additional errors occur only for 10/100/1000T (BASET) optics. Other optics can be used without problems.

EXOS-29882 An error message is reported during rescue following a VOSS to EXOS conversion:
ubiattach: error!: cannot attach "/dev/mtd0"
           error 17 (File exists)
Extended Edge Switching
EXOS-29880 An error message occurs while disabling VPLAG when forwarding mode is in Port-Group mode.